Microfluidic gut-on-a-chip with three-dimensional villi structure
The DOI matches its Crossref record; 56 of the 56 references it cites were found in a registry or an index.
Abstract
Current in vitro gut models lack physiological relevance, and various approaches have been taken to improve current cell culture models. For example, mimicking the three-dimensional (3D) tissue structure or fluidic environment has been shown to improve the physiological function of gut cells. Here, we incorporated a collagen scaffold that mimics the human intestinal villi into a microfluidic device, thus providing cells with both 3D tissue structure and fluidic shear. We hypothesized that the combined effect of 3D structure and fluidic shear may provide cells with adequate stimulus to induce further differentiation and improve physiological relevance. The physiological function of our '3D gut chip' was assessed by measuring the absorptive permeability of the gut epithelium and activity of representative enzymes, as well as morphological evaluation. Our results suggest that the combination of fluidic stimulus and 3D structure induces further improvement in gut functions. Our work provides insight into the effect of different tissue environment on gut cells.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Culturing human Caco-2 intestinal epithelial cells on these crenulated surfaces was shown to promote formation of a similarly crenulated epithelium, and this was accompanied by increased absorption of drug compounds and improved cellular metabolic enzyme cytochrome P-450 activity in response to apical fluid shear stress.39”
From Microfluidic Organ-on-a-Chip Models of Human Intestine (2018) · cites this paper as [39]
In the citing paper
“However, this design did not enable analysis of intestinal barrier function because the solid polymer material blocked the abluminal surface of the epithelium.”
From Microfluidic Organ-on-a-Chip Models of Human Intestine (2018) · cites this paper as [39]
Citations
Cites
Lodish, H. F. (1986) · Cited by 5,650
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250
Stem Cells, Self-Renewal, and Differentiation in the Intestinal Epithelium
van der Flier, L. G., & Clevers, H. (2009) · Annual Review of Physiology · doi:10.1146/annurev.physiol.010908.163145 · Cited by 1,871 · cited 1×
“For example, the gut environment is a complex and dynamic combination of various factors, such as various cell types (van der Flier and Clevers 2009), complex tissue architecture (Lodish 2000), presence of microbiota (Quigley 2013), and peristaltic movement (Huizinga and Lammers 2009).”
BackgroundArtursson, P., Palm, K., & Luthman, K. (2001) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(00)00128-9 · Cited by 1,543
Principles of Anatomy and Physiology
Baker, G. F., Tortora, G. J., & Nostakos, N. P. A. (1976) · The American Journal of Nursing · doi:10.2307/3423898 · Cited by 1,312
(1987) · Comparative Biochemistry and Physiology Part A: Physiology · doi:10.1016/0300-9629(87)90455-5 · Cited by 1,122
Bile acid signaling in metabolic disease and drug therapy
Li, T., & Chiang, J. Y. L. (2014) · Pharmacological Reviews · doi:10.1124/pr.113.008201 · Cited by 935 · cited 1×
“The main sites where absorption and metabolism occur are the intestine and the liver, respectively, which are complex processes with inter-organ signaling (Bieghs and Trautwein 2014; Li and Chiang 2014).”
BackgroundIn vitro microvessels for the study of angiogenesis and thrombosis
Zheng, Y., Chen, J., Craven, M., Choi, N. W., Totorica, S., Diaz-Santana, A., Kermani, P., Hempstead, B., Fischbach-Teschl, C., López, J. A., et al. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1201240109 · Cited by 894
Engineers are from PDMS-land, Biologists are from Polystyrenia
Berthier, E., Young, E. W. K., & Beebe, D. (2012) · Lab on a Chip · doi:10.1039/c2lc20982a · Cited by 799
Gut-on-a-Chip microenvironment induces human intestinal cells to undergo villus differentiation
Kim, H. J., & Ingber, D. E. (2013) · Integrative Biology · doi:10.1039/c3ib40126j · Cited by 750 · cited 7×
“Known as intestinal villi, these structures are believed to aid in increasing the absorptive surface area, and involved in differentiation of gut epithelial cells (Rao and Wang 2010; Kim and Ingber 2013).”
BackgroundResultInfluential
Research works printed but not linked: 6
- V. Bieghs, C. Trautwein, Hepatobiliary Surg Nutr. 3(6), 377–385 (2014)
- M. Chi, B. Yi, S. Oh, D.J. Park, J.H. Sung, S. Park, Biomed. Microdevices 17(3), 9966 (2015)
- S.H. Kim, M. Chi, B. Yi, S.H. Kim, S. Oh, Y. Kim, S. Park, J.H. Sung, Integr Biol (Camb) 6(6), 1222–1232 (2014)
- E.M. Quigley, Gastroenterol Hepatol (NY) 9(9), 560–569 (2013)
- B.R. Ware, S.R. Khetani, Trends Biotechnol. 8(30), 19343–19352 (2016)
- R. Yumoto, T. Murakami, M. Sanemasa, R. Nasu, J. Nagai, M. Takano, Drug Metab. Dispos. 29(2), 145–151 (2001)
Cited by
Development of a primary human Small Intestine-on-a-Chip using biopsy-derived organoids
Kasendra, M., Tovaglieri, A., Sontheimer-Phelps, A., Jalili-Firoozinezhad, S., Bein, A., Chalkiadaki, A., Scholl, W., Zhang, C., Rickner, H., Richmond, C. A., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-21201-7 · Cited by 754
Microfluidic Organ-on-a-Chip Models of Human Intestine
Bein, A., Shin, W., Jalili-Firoozinezhad, S., Park, M. H., Sontheimer-Phelps, A., Tovaglieri, A., Chalkiadaki, A., Kim, H. J., & Ingber, D. E. (2018) · Cellular and Molecular Gastroenterology and Hepatology · doi:10.1016/j.jcmgh.2017.12.010 · Cited by 625
Organ-on-a-Chip: A New Paradigm for Drug Development
Ma, C., Peng, Y., Li, H., & Chen, W. (2021) · Trends in Pharmacological Sciences · doi:10.1016/j.tips.2020.11.009 · Cited by 576
Shin, W., & Kim, H. J. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1810819115 · Cited by 309
“These models have demonstrated the microarchitecture of human intestinal villi (20, 21, 35, 36), a lumen–capillary interface (24), peristalsis-like mechanical dynamics (20, 24), establishment of a host–microbiome ecosystem (20, 24, 37), gut inflammation and immune responses (24), small intestinal bacterial overgrowth…”
Micro and nanoscale technologies in oral drug delivery
Ahadian, S., Finbloom, J. A., Mofidfar, M., Diltemiz, S. E., Nasrollahi, F., Davoodi, E., Hosseini, V., Mylonaki, I., Sangabathuni, S., Montazerian, H., et al. (2020) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2020.07.012 · Cited by 268
Gut-on-a-chip: Current progress and future opportunities
Ashammakhi, N., Nasiri, R., Barros, N. R. D., Tebon, P., Thakor, J., Goudie, M., Shamloo, A., Martin, M. G., & Khademhosseini, A. (2020) · Biomaterials · doi:10.1016/j.biomaterials.2020.120196 · Cited by 235
Organ‐on‐chip models: Implications in drug discovery and clinical applications
Mittal, R., Woo, F. W., Castro, C. S., Cohen, M. A., Karanxha, J., Mittal, J., Chhibber, T., & Jhaveri, V. M. (2019) · Journal of Cellular Physiology · doi:10.1002/jcp.27729 · Cited by 234
“Further developments of the microfluidic device such as collagen scaffolds and use of intestinal biopsies have allowed us to understand nutrient absorption and mucus secretion in the normal intestine (Kasendra et al., 2018; Shim et al., 2017).”
BackgroundFedi, A., Vitale, C., Ponschin, G., Ayehunie, S., Fato, M., & Scaglione, S. (2021) · Journal of Controlled Release · doi:10.1016/j.jconrel.2021.05.028 · Cited by 229
Advances and Current Challenges in Intestinal in vitro Model Engineering: A Digest
Costa, J., & Ahluwalia, A. (2019) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2019.00144 · Cited by 193
“These collagen cell scaffolds were also tested in amicrofluidic device, an aspect which will be described in the next section (Shim et al., 2017).”
BackgroundGut organoids: mini-tissues in culture to study intestinal physiology and disease
Almeqdadi, M., Mana, M. D., Roper, J., & Yilmaz, Ö. H. (2019) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00300.2017 · Cited by 148
de León-Rodríguez, M. D. C. P., Guyot, J., & Laurent-Babot, C. (2018) · Critical Reviews in Food Science and Nutrition · doi:10.1080/10408398.2018.1506734 · Cited by 151
Gut-on-a-chip: Mimicking and monitoring the human intestine
Marrero, D., Pujol‐Vila, F., Vera, D., Gabriel, G., Illa, X., Elizalde‐Torrent, A., Álvarez, M., & Villa, R. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113156 · Cited by 140
Hydrogels as artificial matrices for cell seeding in microfluidic devices
Akther, F., Little, P., Li, Z., Nguyen, N.-T., & Ta, H. T. (2020) · RSC Advances · doi:10.1039/d0ra08566a · Cited by 127
Self-citationMicrofluidic Organ-on-a-Chip System for Disease Modeling and Drug Development
Li, Z., Hui, J., Yang, P., & Mao, H. (2022) · Biosensors · doi:10.3390/bios12060370 · Cited by 120
“PDMS, PET membrane Epi (Caco-2) Soft lithography, photolithography Differentiation, drug absorption, and metabolism [37] Polycarbonate, PDMS, titanium, gold, PET membrane Epi (hAEC) Laser-cut, soft lithography Real-time measurements of barrier function [38]”
BackgroundAdvances in Organ-on-a-Chip Materials and Devices
Nahak, B. K., Mishra, A., Preetam, S., & Tiwari, A. (2022) · ACS Applied Bio Materials · doi:10.1021/acsabm.2c00041 · Cited by 134
Gut-on-chip: Recreating human intestine in vitro
Xiang, Y., Wen, H., Yu, Y., Li, M., Fu, X., & Huang, S. (2020) · Journal of Tissue Engineering · doi:10.1177/2041731420965318 · Cited by 127
Gut-on-a-chip models for dissecting the gut microbiology and physiology
Valiei, A., Aminian-Dehkordi, J., & Mofrad, M. R. K. (2023) · APL Bioengineering · doi:10.1063/5.0126541 · Cited by 128
Gut–liver on a chip toward an in vitro model of hepatic steatosis
Lee, S. Y., & Sung, J. H. (2018) · Biotechnology and Bioengineering · doi:10.1002/bit.26793 · Cited by 111
“In addition, the presence of local fluidic environment can also contribute to enhancement of physiological functions of cells (Shim et al., 2017).”
BackgroundMethodInfluentialSelf-citationMicrofluidic Tissue Engineering and Bio‐Actuation
Filippi, M., Buchner, T., Yaşa, Ö., Weirich, S., & Katzschmann, R. K. (2022) · Advanced Materials · doi:10.1002/adma.202108427 · Cited by 133
Fowler, S., Chen, W. L. K., Duignan, D. B., Gupta, A., Hariparsad, N., Kenny, J. R., Lai, W. G., Liras, J., Phillips, J. A., & Gan, J. (2020) · Lab on a Chip · doi:10.1039/c9lc00857h · Cited by 109
Babadi, D., Dadashzadeh, S., Osouli, M., Daryabari, M. S., & Haeri, A. (2020) · Journal of Controlled Release · doi:10.1016/j.jconrel.2020.02.041 · Cited by 108
Flat and microstructured polymeric membranes in organs-on-chips
Pasman, T., Grijpma, D., Stamatialis, D., & Poot, A. (2018) · Journal of The Royal Society Interface · doi:10.1098/rsif.2018.0351 · Cited by 98
“In fact, several OOCs simply use membranes found in commercial inserts (1, 15, 21, 26, 29, 39, 43, 48, 52) or filter membranes (3, 16, 23, 25, 27, 41, 43, 44, 51).”
BackgroundMethodInfluentialThe emergence of 3D bioprinting in organ-on-chip systems
Fetah, K., Tebon, P., Goudie, M. J., Eichenbaum, J., Ren, L., Barros, N., Nasiri, R., Ahadian, S., Ashammakhi, N., Dokmeci, M. R., et al. (2019) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/ab23df · Cited by 98
“A different method of recreating the villus structures was published by Shim et al [192].”
BackgroundMethodThe Past, Present and Future of Intestinal In Vitro Cell Systems for Drug Absorption Studies
Youhanna, S. C., & Lauschke, V. M. (2020) · Journal of Pharmaceutical Sciences · doi:10.1016/j.xphs.2020.07.001 · Cited by 116
Engineering mucus to study and influence the microbiome
Werlang, C. A., Cárcamo‐Oyarce, G., & Ribbeck, K. (2019) · Nature Reviews Materials · doi:10.1038/s41578-018-0079-7 · Cited by 107
Liu, S., Kumari, S., He, H., Mishra, P., Singh, B. N., Singh, D., Liu, S., Srivastava, P., & Li, C. (2023) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2023.115285 · Cited by 112
Organ-on-Chip Approaches for Intestinal 3D In Vitro Modeling
Pimenta, J. M., Ribeiro, R. D. C., Almeida, R., Costa, P. F., da Silva, M. A., & Pereira, B. (2021) · Cellular and Molecular Gastroenterology and Hepatology · doi:10.1016/j.jcmgh.2021.08.015 · Cited by 101
“In the case of intestine-on-chip models, the villi of the intestinal mucosa has been re-created mostly by micromolding.(17,56) Although these studies have shown that the combination of fluidic flow with the re-creation of the intestinal 3D microarchitecture induced Caco-2 cells to behave more similarly to the native t…”
BackgroundEngineering Tissue Barrier Models on Hydrogel Microfluidic Platforms
Vera, D., García-Díaz, M., Torras, N., Álvarez, M., Villa, R., & Martínez, E. (2021) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.0c21573 · Cited by 96
Zheng, F., Xiao, Y., Liu, H., Fan, Y., & Dao, M. (2021) · Advanced Biology · doi:10.1002/adbi.202000024 · Cited by 108
Kavand, H., Nasiri, R., & Herland, A. (2022) · Advanced Materials · doi:10.1002/adma.202107876 · Cited by 95
Mimicking Epithelial Tissues in Three-Dimensional Cell Culture Models
Torras, N., García-Díaz, M., Fernández‐Majada, V., & Martínez, E. (2018) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2018.00197 · Cited by 101
“, 2018) and gut-on-a-chip designs included a porous scaffold that mimicked the 3D villus architecture of the small intestine (Costello et al., 2017; Shim et al., 2017).”
Background3D gut-liver chip with a PK model for prediction of first-pass metabolism
Lee, D. W., Ha, S. K., Choi, I., & Sung, J. H. (2017) · Biomedical Microdevices · doi:10.1007/s10544-017-0242-8 · Cited by 86
Self-citationFois, C. A. M., Schindeler, A., Valtchev, P., & Dehghani, F. (2021) · Biomedical Microdevices · doi:10.1007/s10544-021-00591-y · Cited by 82
Folding artificial mucosa with cell-laden hydrogels guided by mechanics models
Chan, H. F., Zhao, R. R., Parada, G. A., Meng, H., Leong, K. W., Griffith, L. G., & Zhao, X. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1802361115 · Cited by 85
“There are other morphological patterns induced by mechanical instabilities of film–substrate structures present in biological systems, such as ridge found in intestinal villi (55).”
BackgroundIntegration of Extracellular Matrices into Organ‐on‐Chip Systems
Kutluk, H., Bastounis, E. E., & Constantinou, I. (2023) · Advanced Healthcare Materials · doi:10.1002/adhm.202203256 · Cited by 84
Human Microphysiological Models of Intestinal Tissue and Gut Microbiome
Steinway, S. N., Saleh, J., Koo, B., Delacour, D., & Kim, D. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.00725 · Cited by 84
Kulthong, K., Duivenvoorde, L. P. M., Sun, H., Confederat, S., Wu, J., Spenkelink, B., de Haan, L., Marin, V., van der Zande, M., & Bouwmeester, H. (2020) · Toxicology in Vitro · doi:10.1016/j.tiv.2020.104815 · Cited by 87
Microfluidic Gut-on-a-Chip: Fundamentals and Challenges
Thomas, D. P., Zhang, J., Nguyen, N., & Ta, H. T. (2023) · Biosensors · doi:10.3390/bios13010136 · Cited by 95
“, developed collagen-based villi-like structures via soft lithography [26].”
BackgroundInfluentialSelf-citationBiomedical Application of Functional Materials in Organ-on-a-Chip
Ding, C., Chen, X., Kang, Q., & Yan, X. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.00823 · Cited by 89
“The first-generation microscale cell culture analog (µCCA) devices mimicking the organ-level function of human physiology were fabricated on silicon (Sin et al., 2004; Mahler et al., 2009).”
BackgroundLong-term flow through human intestinal organoids with the gut organoid flow chip (GOFlowChip)
Sidar, B., Jenkins, B. R., Huang, S., Spence, J. R., Walk, S. T., & Wilking, J. N. (2019) · Lab on a Chip · doi:10.1039/c9lc00653b · Cited by 73
de Haan, P., Ianovska, M. A., Mathwig, K., van Lieshout, G. A. A., Triantis, V., Bouwmeester, H., & Verpoorte, E. M. J. (2019) · Lab on a Chip · doi:10.1039/c8lc01080c · Cited by 79
Mimicking Human Pathophysiology in Organ‐on‐Chip Devices
Yeşil-Çeliktaş, Ö., Hassan, S., Miri, A. K., Maharjan, S., Al‐kharboosh, R., Quiñones‐Hinojosa, A., & Zhang, Y. S. (2018) · Advanced Biosystems · doi:10.1002/adbi.201800109 · Cited by 81
A Review of Biomaterials and Scaffold Fabrication for Organ-on-a-Chip (OOAC) Systems
Osório, L. A., Silva, E., & Mackay, R. E. (2021) · Bioengineering · doi:10.3390/bioengineering8080113 · Cited by 81
Organ-on-a-chip: A new tool for in vitro research
Yan, J., Li, Z., Guo, J., Liu, S., & Guo, J. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2022.114626 · Cited by 77
Santbergen, M. J. C., van der Zande, M., Gerssen, A., Bouwmeester, H., & Nielen, M. W. F. (2019) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-019-02336-6 · Cited by 72
In Vitro Immune Organs-on-Chip for Drug Development: A Review
Shanti, A., Teo, J., & Stefanini, C. (2018) · Pharmaceutics · doi:10.3390/pharmaceutics10040278 · Cited by 65
Organoids/organs-on-a-chip: new frontiers of intestinal pathophysiological models
Wu, L., Ai, Y., Xie, R., Xiong, J., Wang, Y., & Liang, Q. (2023) · Lab on a Chip · doi:10.1039/d2lc00804a · Cited by 69
Standardizing designed and emergent quantitative features in microphysiological systems
Nahon, D. M., Moerkens, R., Aydoğmuş, H., Lendemeijer, B., Martínez-Silgado, A., Stein, J. M., Dostanić, M., Frimat, J., Gontan, C., de Graaf, M. N. S., et al. (2024) · Nature Biomedical Engineering · doi:10.1038/s41551-024-01236-0 · Cited by 72
“…tracers can be used to quantify the bidirectional permeability of a barrier, as they are transported through passive paracellular absorption in the influx direction and through carrier-mediated transport in the efflux direction, as was shown for rhodamine 123 in a perfused GoC microchamber 73,74 .”
Shija, V. M., Amoah, K., & Cai, J. X. (2023) · Fishes · doi:10.3390/fishes8070366 · Cited by 69
Immunological Regulation of Intestinal Fibrosis in Inflammatory Bowel Disease
Bamias, G., Pizarro, T. T., & Cominelli, F. (2021) · Inflammatory Bowel Diseases · doi:10.1093/ibd/izab251 · Cited by 60
Kimura, H., Nishikawa, M., Kutsuzawa, N., Tokito, F., Kobayashi, T., Kurniawan, D. A., Shioda, H., Cao, W., Shinha, K., Nakamura, H., et al. (2024) · Drug Metabolism and Pharmacokinetics · doi:10.1016/j.dmpk.2024.101046 · Cited by 67
Ceppa, F., Izzo, L., Sardelli, L., Raimondi, I., Tunesi, M., Albani, D., & Giordano, C. (2020) · Frontiers in Cellular and Infection Microbiology · doi:10.3389/fcimb.2020.00297 · Cited by 60
Youhanna, S. C., Kemas, A. M., Preiss, L. C., Zhou, Y., Shen, J. X., Cakal, S. D., Paqualini, F. S., Goparaju, S. K., Shafagh, R. Z., Lind, J. U., et al. (2022) · Pharmacological Reviews · doi:10.1124/pharmrev.120.000238 · Cited by 67
Engineered Biomimetic Membranes for Organ-on-a-Chip
Rahimnejad, M., Rasouli, F., Jahangiri, S., Ahmadi, S., Rabiee, N., Farani, M. R., Akhavan, O., Asadnia, M., Fatahi, Y., Hong, S., et al. (2022) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.2c00531 · Cited by 59
A microfluidic chip with gravity‐induced unidirectional flow for perfusion cell culture
Lee, D. W., Choi, N., & Sung, J. H. (2019) · Biotechnology Progress · doi:10.1002/btpr.2701 · Cited by 54
Self-citationGut-on-a-chip for disease models
Xian, C., Zhang, J., Zhao, S., & Li, X. (2023) · Journal of Tissue Engineering · doi:10.1177/20417314221149882 · Cited by 57
Multi-organ-on-a-chip for pharmacokinetics and toxicokinetic study of drugs
Sung, J. H. (2021) · Expert Opinion on Drug Metabolism & Toxicology · doi:10.1080/17425255.2021.1908996 · Cited by 59
Self-citationGut-on-a-Chip Models: Current and Future Perspectives for Host–Microbial Interactions Research
Morelli, M., Kurek, D., Ng, C. P., & Queiroz, K. C. S. (2023) · Biomedicines · doi:10.3390/biomedicines11020619 · Cited by 69
Intestine-on-a-chip: Next level in vitro research model of the human intestine
Donkers, J. M., Amirabadi, H. E., & van de Steeg, E. (2020) · Current Opinion in Toxicology · doi:10.1016/j.cotox.2020.11.002 · Cited by 57
PBPK Modeling on Organs-on-Chips: An Overview of Recent Advancements
Yang, Y., Chen, Y., Wang, L., Xu, S., Fang, G., Guo, X., Chen, Z., & Gu, Z. (2022) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2022.900481 · Cited by 62
“A series of 3D structures (Lee et al., 2019; Oso ́rio et al., 2021; Shim et al., 2017) have been proposed to better mimic human physiology.”
BackgroundIntegrated biosensors for monitoring microphysiological systems
Mou, L., Mandal, K., Mecwan, M. M., Hernández, A. L., Maity, S., Sharma, S., Herculano, R. D., Kawakita, S., Jucaud, V., Dokmeci, M. R., et al. (2022) · Lab on a Chip · doi:10.1039/d2lc00262k · Cited by 59
Lymph Nodes-On-Chip: Promising Immune Platforms for Pharmacological and Toxicological Applications
Shanti, A., Hallfors, N., Petroianu, G. A., Planelles, L., & Stefanini, C. (2021) · Frontiers in Pharmacology · doi:10.3389/fphar.2021.711307 · Cited by 50
“These techniques have enabled the development of extremely intricate structures that closely resemble those in vivo and these include the villi of the small intestine and the alveoli of the lungs (Shim et al., 2017; Stucki et al., 2018).”
BackgroundIntestine‐on‐chip device increases ECM remodeling inducing faster epithelial cell differentiation
Gregorio, V. D., Corrado, B., Sbrescia, S., Sibilio, S., Urciuolo, F., Netti, P. A., & Imparato, G. (2019) · Biotechnology and Bioengineering · doi:10.1002/bit.27186 · Cited by 50
Human Organs‐on‐Chips: A Review of the State‐of‐the‐Art, Current Prospects, and Future Challenges
Zarrintaj, P., Saeb, M. R., Stadler, F. J., Yazdi, M. K., Nasirinezhad, M., Mohebbi, S., Seidi, F., Ganjali, M. R., & Mozafari, M. (2021) · Advanced Biology · doi:10.1002/adbi.202000526 · Cited by 57
Kumar, D., Nadda, R., & Repaka, R. (2024) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-024-03062-7 · Cited by 64
“This method has benefits for drug development, such as the ability to run [122], [135] several organ culture devices simultaneously, compatibility with pipette-based fluid management, versatility in the design of the microfluidic system, analytical methods in microplates, and adaptability to widely…”
In vitro hepatic steatosis model based on gut–liver‐on‐a‐chip
Jeon, J., Lee, S. H., Kim, D., & Sung, J. H. (2021) · Biotechnology Progress · doi:10.1002/btpr.3121 · Cited by 54
“Several research groups reported that gut cells cultured in a microfluidic environment show changes in their physiological properties.(29,40,65) It is plausible that Caco-2 cells cultured in the chip underwent changes in their physiological properties, which caused changes in their”
BackgroundMethodResultInfluentialSelf-citationKim, M., van Noort, D., Sung, J. H., & Park, S. (2021) · International Journal of Molecular Sciences · doi:10.3390/ijms222413513 · Cited by 48
Self-citationIn Vitro Models of the Small Intestine: Engineering Challenges and Engineering Solutions
Hewes, S. A., Wilson, R. L., Estes, M. K., Shroyer, N. F., Blutt, S. E., & Grande-Allen, K. J. (2020) · Tissue Engineering Part B Reviews · doi:10.1089/ten.teb.2019.0334 · Cited by 56
“Other similar microfluidic designs do not include stretch or allow simultaneous flow over both sides of the membrane, but have made significant innovations to other design aspects.(132,133,141) One model was designed to be integrated FIG.”
BackgroundMethodLee, Y., Kim, M., Alves, D. R., Kim, S., Lee, L. P., Sung, J. H., & Park, S. (2021) · Toxins · doi:10.3390/toxins13110775 · Cited by 49
Self-citationSingh, D. K., Miller, C. M., Orgel, K., Dave, M., Mackay, S., & Good, M. L. (2023) · Frontiers in Pediatrics · doi:10.3389/fped.2022.1107404 · Cited by 57
Vera, D., García-Díaz, M., Torras, N., Castillo, Ó., Illa, X., Villa, R., Álvarez, M., & Martínez, E. (2024) · Biofabrication · doi:10.1088/1758-5090/ad3aa4 · Cited by 53
“As an example, soft lithography was used to pattern collagen I—based hydrogels with villi-like pillars [19].”
MethodPharmacokinetic and pharmacodynamic insights from microfluidic intestine-on-a-chip models
Lee, S. H., Choi, N., & Sung, J. H. (2019) · Expert Opinion on Drug Metabolism & Toxicology · doi:10.1080/17425255.2019.1700950 · Cited by 45
“Sung’s group cultured the Caco-2 cells on PEG-DA or collagen-based villi scaffolds with gravity-induced flow [67,68].”
BackgroundSelf-citationGut-microbiota-on-a-chip: an enabling field for physiological research
Trujillo-de Santiago, G., Lobo-Zegers, M. J., Montes-Fonseca, S. L., Zhang, Y. S., & Alvarez, M. M. (2018) · Microphysiological Systems · doi:10.21037/mps.2018.09.01 · Cited by 43
“A series of papers have described the development and use (again mainly for tissue engineering purposes) of collagen-based scaffolds that resemble the 3D structure of the finger-like intestinal villi (78,79,84,85), such as the ones present in ileum and jejune.”
BackgroundModels of the Gut for Analyzing the Impact of Food and Drugs
Fois, C. A. M., Le, T. Y. L., Schindeler, A., Naficy, S., McClure, D. D., Read, M. N., Valtchev, P., Khademhosseini, A., & Dehghani, F. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201900968 · Cited by 47
Wan, J., Zhou, S., Mea, H. J., Guo, Y., Ku, H., & Urbina, B. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00480 · Cited by 54
Kamei, K., Yoshioka, M., Terada, S., Tokunaga, Y., & Chen, Y. (2019) · Biomedical Microdevices · doi:10.1007/s10544-019-0423-8 · Cited by 44
Recent Advances in Gut‐ and Gut–Organ‐Axis‐on‐a‐Chip Models
Kim, R., & Sung, J. H. (2024) · Advanced Healthcare Materials · doi:10.1002/adhm.202302777 · Cited by 53
Self-citationSignore, M. A., Pascali, C. D., Giampetruzzi, L., Siciliano, P. A., & Francioso, L. N. (2021) · Sensing and Bio-Sensing Research · doi:10.1016/j.sbsr.2021.100443 · Cited by 45
Organoids meet microfluidics: recent advancements, challenges, and future of organoids-on-chip
Chauhdari, T., Zaidi, S. A., Su, J., & Ding, Y. (2025) · In vitro models · doi:10.1007/s44164-025-00086-7 · Cited by 46
“…derived from patients recapitulate the features of the duodenum, including the formation of villi-like structures lined by a polarized epithelium expressing markers of enterocytes, goblet cells, and enteroendocrine cells, without the use of any micropatterned villus-shaped scaffold [95, 96].”
A Theoretical and Experimental Study to Optimize Cell Differentiation in a Novel Intestinal Chip
Langerak, N. A. J., Ahmed, H. M. M., Li, Y., Middel, I. R., Amirabadi, H. E., Malda, J., Masereeuw, R., & van Roij, R. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.00763 · Cited by 37
“Similarly, shear stress has been shown to improve Caco2 differentiation compared to static cultures (Kim and Ingber, 2013; Shim et al., 2017).”
BackgroundIn Vitro Human Gastrointestinal Tract Simulation Systems: A Panoramic Review
Dixit, Y. M., Kanojiya, K., Bhingardeve, N., Ahire, J. J., & Saroj, D. B. (2023) · Probiotics and Antimicrobial Proteins · doi:10.1007/s12602-023-10052-y · Cited by 40
“Beside this, it is also possible to build three-dimensional organ-specific structures such as crypts or villi, to mimic real miniaturised architecture using gut-on-a-chip models [89, 90].”
Gregorio, V. D., Imparato, G., Urciuolo, F., & Netti, P. A. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.09.061 · Cited by 36
Busch, M., Brouwer, H., Aalderink, G., Bredeck, G., Kämpfer, A. A. M., Schins, R. P. F., & Bouwmeester, H. (2023) · Frontiers in Toxicology · doi:10.3389/ftox.2023.1112212 · Cited by 37
“By generating scaffold-like (Shim et al., 2017) or tubular structures (Naumovska et al.”
BackgroundWang, H., Li, X., Shi, P., You, X., & Zhao, G. (2024) · Materials Today Bio · doi:10.1016/j.mtbio.2024.101079 · Cited by 47
“Reproducing the in vivo -like microenvironment [33,36,38] 4.”
BackgroundInfluentialMimicking the Human Physiology with Microphysiological Systems (MPS)
Sung, J. H., Koo, J., & Shuler, M. L. (2019) · BioChip Journal · doi:10.1007/s13206-019-3201-z · Cited by 34
Self-citationA microfluidic organotypic device for culture of mammalian intestinesex vivo
Richardson, A., Schwerdtfeger, L., Eaton, D., McLean, I. C., Henry, C. S., & Tobet, S. A. (2020) · Analytical Methods · doi:10.1039/c9ay02038a · Cited by 40
Oral fate and stabilization technologies of lactoferrin: a systematic review
Wei, Y., Feng, K., Li, S., Hu, T., Linhardt, R. J., Zong, M., & Wu, H. (2021) · Critical Reviews in Food Science and Nutrition · doi:10.1080/10408398.2021.1900774 · Cited by 31
“These experiments are promising when applied for more accurate characterization of the intestinal absorption behavior of bioactive proteins (Imura, Yoshimura, and Sato 2012; Ramadan et al. 2013; Shim et al. 2017; de Santiago et al. 2018).”
BackgroundValencia, L., Canalejas-Tejero, V., Clemente, M., Fernaud, I., Holgado, M., Jorcano, J. L., & Velasco, D. (2021) · Scientific Reports · doi:10.1038/s41598-021-91875-z · Cited by 33
Organoids as regenerative medicine for inflammatory bowel disease
Hammerhøj, A., Chakravarti, D., Sato, T., Jensen, K. B., & Nielsen, O. H. (2024) · iScience · doi:10.1016/j.isci.2024.110118 · Cited by 37
Using multi-organ culture systems to study Parkinson’s disease
Reiner, O., Sapir, T., & Parichha, A. (2020) · Molecular Psychiatry · doi:10.1038/s41380-020-00936-8 · Cited by 33
“These deficits may be overcome in gut chip models [79, 84].”
BackgroundA review of organ-on-chip fabrication methods: From early developments to overcoming inert barriers
Olaizola‐Rodrigo, C., Bayona, C., Oliván, S., & Monge, R. (2025) · iScience · doi:10.1016/j.isci.2025.113992 · Cited by 35
Revealing transport, uptake and damage of polystyrene microplastics using a gut-liver-on-a-chip
Wang, Y., Han, J., Tang, W., Zhang, X., Ding, J., Xu, Z., Song, W., Li, X., & Wang, L. (2025) · Lab on a Chip · doi:10.1039/d4lc00578c · Cited by 32
Self-citationMulti-organ on a chip for personalized precision medicine
Palaninathan, V., Kumar, V., Maekawa, T., Liepmann, D., Paulmurugan, R., Eswara, J. R., Ajayan, P. M., Augustine, S., Malhotra, B. D., Viswanathan, S., et al. (2018) · MRS Communications · doi:10.1557/mrc.2018.148 · Cited by 29
Wang, L., Wu, J., Chen, J., Dou, W., Zhao, Q., Han, J., Liu, J., Su, W., Li, A., Liu, P., et al. (2021) · Talanta · doi:10.1016/j.talanta.2021.122097 · Cited by 29
“Picture of a gut chip showing two sets of reservoirs for the apical (red) and basolateral sides (blue) [141].”
BackgroundSelf-citationZhao, Q., Cole, T., Zhang, Y., & Tang, S. (2021) · Micromachines · doi:10.3390/mi12070765 · Cited by 34
In vitro models to evaluate ingestible devices: Present status and current trends
O’Farrell, C., Stamatopoulos, K., Simmons, M. J. H., & Batchelor, H. K. (2021) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2021.113924 · Cited by 36
vasQchip: A Novel Microfluidic, Artificial Blood Vessel Scaffold for Vascularized 3D Tissues
Kappings, V., Grün, C., Ivannikov, D., Hebeiss, I., Kattge, S., Wendland, I., Rapp, B. E., Hettel, M., Deutschmann, O., & Schepers, U. (2018) · Advanced Materials Technologies · doi:10.1002/admt.201700246 · Cited by 29
Microfluidics for 3D Cell and Tissue Cultures: Microfabricative and Ethical Aspects Updates
Limongi, T., Guzzi, F., Parrotta, E. I., Candeloro, P., Scalise, S., Lucchino, V., Gentile, F., Tirinato, L., Coluccio, M. L., Torre, B., et al. (2022) · Cells · doi:10.3390/cells11101699 · Cited by 29
Advances of microfluidic intestine-on-a-chip for analyzing anti-inflammation of food
Liang, D., Su, W., & Tan, M. (2021) · Critical Reviews in Food Science and Nutrition · doi:10.1080/10408398.2021.1875395 · Cited by 27
“Sandwiched design Caco-2 – Fluorescein (47 kDa) Rhodamine 123 ( 84 kDa) – Actin 6000 Mimicking 3 D tissue structure or fluidic stress to improve the physiological function (Shim et al. 2017)”
BackgroundTaavitsainen, S., Juuti‐Uusitalo, K., Kurppa, K., Lindfors, K., Kallio, P. J., & Kellomäki, M. (2024) · Frontiers in Lab on a Chip Technologies · doi:10.3389/frlct.2023.1337945 · Cited by 32
Metadata
- Authors
- Shim, K.-Y., Lee, D., Han, J., Nguyen, N.-T., Park, S., & Sung, J. H.
- Affiliations
- Hongik University (KR)
- Sungkyunkwan University (KR)
- Griffith University (AU)
- Corresponding author
- Park, Sungsu
- Sung, Jong Hwan
- Venue
- Biomedical Microdevices
- Published
- 2017-04-27
- Volume
- 19
- Issue
- 2
- Pages
- 37-37
- ISSN
- 1387-2176 (ISSN-L)
- 1572-8781
- OpenAlex
- W2609369954
- Cited by
- 229
- References
- 56
- Citations by year
- 2026: 10 · 2025: 27 · 2024: 26 · 2023: 33 · 2022: 27 · 2021: 35 · 2020: 27 · 2019: 22 · 2018: 20 · 2017: 2
- FWCI
- 8.74
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Biomedical Microdevices (publishedVersion)
- PubMed (publishedVersion)
- Griffith Research Online (submittedVersion)
- Funders
- Ministry of Trade, Industry and Energy (MOTIE), Republic of Korea (R0004073)
- National Research Foundation of Korea (NRF) grant funded by the Korea government (MSIP) (2016R1C1B1009747)
- KFRI (Korea Food Research Institute) (E0121705)
- Hongik University (Faculty Research Fund)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
- Keywords
- gut-on-a-chip, intestinal villi, collagen scaffolds, intestinal epithelium, enzyme activity, cell differentiation, in vitro gut model, microfluidics
- MeSH terms
- Collagen, Dimethylpolysiloxanes, Humans, Intestinal Mucosa, Intestines, Membranes, Artificial, Permeability, Porosity, Caco-2 Cells, Lab-On-A-Chip Devices
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.