Breast cancer screening using tomosynthesis in combination with digital mammography compared to digital mammography alone: a cohort study within the PROSPR consortium
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Digital breast tomosynthesis (DBT) is emerging as the new standard of care for breast cancer screening based on improved cancer detection coupled with reductions in recall compared to screening with digital mammography (DM) alone. However, many prior studies lack follow-up data to assess false negatives examinations. The purpose of this study is to assess if DBT is associated with improved screening outcomes based on follow-up data from tumor registries or pathology. Retrospective analysis of prospective cohort data from three research centers performing DBT screening in the PROSPR consortium from 2011 to 2014 was performed. Recall and biopsy rates were assessed from 198,881 women age 40–74 years undergoing screening (142,883 DM and 55,998 DBT examinations). Cancer, cancer detection, and false negative rates and positive predictive values were assessed on examinations with one year of follow-up. Logistic regression was used to compare DBT to DM adjusting for research center, age, prior breast imaging, and breast density. There was a reduction in recall with DBT compared to DM (8.7 vs. 10.4 %, p < 0.0001), with adjusted OR = 0.68 (95 % CI = 0.65–0.71). DBT demonstrated a statistically significant increase in cancer detection over DM (5.9 vs. 4.4/1000 screened, adjusted OR = 1.45, 95 % CI = 1.12–1.88), an improvement in PPV1 (6.4 % for DBT vs. 4.1 % for DM, adjusted OR = 2.02, 95 % CI = 1.54–2.65), and no significant difference in false negative rates for DBT compared to DM (0.46 vs. 0.60/1000 screened, p = 0.347). Our data support implementation of DBT screening based on increased cancer detection, reduced recall, and no difference in false negative screening examinations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Skaane, P., Bandos, A. I., Gullien, R., Eben, E. B., Ekseth, U., Haakenaasen, U., Izadi, M., Jebsen, I. N., Jahr, G., Krager, M., et al. (2013) · Radiology · doi:10.1148/radiol.12121373 · Cited by 1,012 · cited 1×
“In Skaane’s interval analysis of the first 12,621 subjects screened in a multi-arm, prospective trial with only 9 months of follow-up [4], there was a 40 % increase in invasive cancers and 3 known interval cancers for a rate of 0.”
MethodBreast Cancer Screening Using Tomosynthesis in Combination With Digital Mammography
Friedewald, S. M., Rafferty, E. A., Rose, S. L., Durand, M. A., Plecha, D. M., Greenberg, J. S., Hayes, M. K., Copit, D. S., Carlson, K. L., Cink, T. M., et al. (2014) · JAMA · doi:10.1001/jama.2014.6095 · Cited by 851
Self-citationCiatto, S., Houssami, N., Bernardi, D., Caumo, F., Pellegrini, M., Brunelli, S., Tuttobene, P., Bricolo, P., Fantò, C., Valentini, M., et al. (2013) · The Lancet Oncology · doi:10.1016/s1470-2045(13)70134-7 · Cited by 838
Digital tomosynthesis in breast imaging.
Niklason, L. T., Christian, B. T., Niklason, L. E., Kopans, D. B., Castleberry, D. E., Opsahl-Ong, B. H., Landberg, C. E., Slanetz, P. J., Giardino, A. A., Moore, R., et al. (1997) · Radiology · doi:10.1148/radiology.205.2.9356620 · Cited by 763 · cited 1×
“The ability to scroll through the multiple reconstructed images minimizes the impact of overlapping structure which limits two-dimensional mammographic imaging [3].”
BackgroundHaas, B. M., Kalra, V., Geisel, J., Raghu, M., Durand, M., & Philpotts, L. E. (2013) · Radiology · doi:10.1148/radiol.13130307 · Cited by 419
Implementation of Breast Tomosynthesis in a Routine Screening Practice: An Observational Study
Rose, S. L., Tidwell, A. L., Bujnoch, L. J., Kushwaha, A. C., Nordmann, A. S., & Sexton, R. (2013) · American Journal of Roentgenology · doi:10.2214/ajr.12.9672 · Cited by 329
Sechopoulos, I. (2013) · Medical Physics · doi:10.1118/1.4770281 · Cited by 253 · cited 1×
“This novel x-ray technique images the breast with multiple lowdose exposures obtained along an arc which are reconstructed into a series of thin images or ‘‘slices’’ of the breast [1, 2].”
BackgroundOnega, T., Beaber, E. F., Sprague, B. L., Barlow, W. E., Haas, J. S., Tosteson, A. N. A., Schnall, M. D., Armstrong, K., Schapira, M. M., Geller, B. M., et al. (2014) · Cancer · doi:10.1002/cncr.28771 · Cited by 148
Self-citationHoussami, N., Abraham, L., Kerlikowske, K. M., Buist, D. S. M., Irwig, L., Lee, J., & Miglioretti, D. L. (2013) · Cancer Epidemiology Biomarkers & Prevention · doi:10.1158/1055-9965.epi-12-1208-t · Cited by 60 · cited 1×
“The classic definition of an interval cancer is a cancer that presents symptomatically after a negative screening exam, and before the next scheduled screen [17].”
Background
Cited by
Screening for Breast Cancer: US Preventive Services Task Force Recommendation Statement
US Preventive Services Task Force, Nicholson, W. K., Silverstein, M., Wong, J. B., Barry, M. J., Chelmow, D., Coker, T. R., Davis, E. M., Jaén, C. R., Krousel-Wood, M., et al. (2024) · JAMA · doi:10.1001/jama.2024.5534 · Cited by 463
Digital Breast Tomosynthesis: Concepts and Clinical Practice
Chong, A., Weinstein, S. P., McDonald, E. S., & Conant, E. F. (2019) · Radiology · doi:10.1148/radiol.2019180760 · Cited by 243
Self-citationConant, E. F., Barlow, W. E., Herschorn, S. D., Weaver, D. L., Beaber, E. F., Tosteson, A. N. A., Haas, J. S., Lowry, K. P., Stout, N. K., Trentham-Dietz, A., et al. (2019) · JAMA Oncology · doi:10.1001/jamaoncol.2018.7078 · Cited by 217
Self-citationSkaane, P., Bandos, A. I., Niklason, L. T., Sebuødegård, S., Østerås, B. H., Gullien, R., Gur, D., & Hofvind, S. (2019) · Radiology · doi:10.1148/radiol.2019182394 · Cited by 171
Talaat, F. M., Gamel, S. A., El-Balka, R. M., Shehata, M., & ZainEldin, H. (2024) · Cancers · doi:10.3390/cancers16213668 · Cited by 67
“DBT is becoming the preferred method due to its ability to provide more detailed images and reduce the need for additional views [11,12].”
Background
Metadata
- Authors
- Conant, E. F., Beaber, E. F., Sprague, B. L., Herschorn, S. D., Weaver, D. L., Onega, T., Tosteson, A. N. A., McCarthy, A. M., Poplack, S. P., Haas, J. S., Armstrong, K., Schnall, M. D., & Barlow, W. E.
- Venue
- Breast Cancer Research and Treatment
- Published
- 2016-02
- Volume
- 156
- Issue
- 1
- Pages
- 109-116
- ISSN
- 0167-6806 (ISSN-L)
- 1573-7217
- OpenAlex
- W2288795666
- Cited by
- 184
- References
- 9
- FWCI
- 23.30
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.