Cited by 25Corneal surgery and disordersCorneal Surgery and TreatmentsOcular Surface and Contact Lens

A portable device for measuring donor corneal transparency in eye banks

Parekh, Mohit, Ferrari, Stefano, Ruzza, Alessandro, Pugliese, Mariarosaria, Ponzin, Diego, Salvalaio, Gianni·2014·Cell and Tissue Banking

Abstract

To develop a portable device for measuring the donor corneal transparency and validate its efficacy for corneal evaluation in the eye-banks and for research. The transparency device (TD) has a light source, a detachable system for corneal insertion and a base for light transmission. The probe detects the transmitted light which is measured by a lux-meter. A contact lens was set as 'control' to reduce the light scattering concern, an empty petri-plate as 'blank' and the cornea as 'sample'. Two experts and non-experts (masked) observed the corneas for subjective analysis which was then compared using the TD. The parameters observed were scars, foreign-body, stromal-deformities, folds, thickness and opacity which were then converted to a relative overall percentage by the observer. Twenty corneas were evaluated for correlation, five tissues to obtain standard-deviation and twenty-four pairs for a comparative study. Experts mimicked the eye-banks with long-term experience while non-experts mimicked the emerging eye-banks. Subjective values by the experts closely resembled the measurements by TD. The average correlation between the experts and the non-experts to TD was 0.985 and 0.960 respectively. TD showed higher reproducibility than experts followed by the non-experts. The comparative study showed that increase in thickness reduces the transparency. TD is portable, easy, efficient, maintains sterility and less expensive hence the emerging eye-banks and researchers can use to ra…

Integrity signals

Registry

Crossref · 10.1007/s10561-013-9372-2

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The two most commonly used techniques to measure corneal transparency ex vivo are tungsten light-based or laser-based bench-top optical systems, or spectrophotometry.

    “The two most commonly used techniques to measure corneal transparency ex vivo are tungsten light-based or laser-based bench-top optical systems (Farrell et al., 1973, Christens-Barry et al., 1996, Parekh et al., 2014), or spectrophotometry (Cejka et al., 2010, Doutch et al., 2008).”

    From Corneal structure and transparency (2015) · cites this paper as Parekh et al., 2014

Cited by

Sorted by citations

Authors
Parekh, M., Ferrari, S., Ruzza, A., Pugliese, M., Ponzin, D., & Salvalaio, G.
Affiliations
Veneto Eye Bank Foundation (IT)
Corresponding author
Parekh, Mohit
Venue
Cell and Tissue Banking
Published
2013-04-27
Volume
15
Issue
1
Pages
7-13
ISSN
  • 1389-9333 (ISSN-L)
  • 1573-6814
OpenAlex
W2041405582
Cited by
25
References
0
Citations by year
2026: 2 · 2025: 2 · 2024: 1 · 2023: 1 · 2022: 1 · 2021: 2 · 2020: 1 · 2019: 5 · 2018: 2 · 2017: 2 · 2015: 2 · 2014: 2 · 2013: 2
FWCI
1.55
Type
journal article
Language
en
Open access
closed
Locations
  • Cell and Tissue Banking (publishedVersion)
  • PubMed (publishedVersion)
  • Institutional Research Information System University of Ferrara (University of Ferrara) (submittedVersion)
Funders
Ögonfonden
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Corneal surgery and disorders
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Corneal Surgery and Treatments
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Ocular Surface and Contact Lens
Keywords
donor cornea, corneal transparency, eye bank, portable measurement system, optical transmittance, corneal opacity, corneal thickness, reproducibility
MeSH terms
Cornea, Eye Banks, Humans, Tissue Donors, Vision, Ocular, Corneal Transplantation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review