Corneal structure and transparency
Open accessAbstract
The corneal stroma plays several pivotal roles within the eye. Optically, it is the main refracting lens and thus has to combine almost perfect transmission of visible light with precise shape, in order to focus incoming light. Furthermore, mechanically it has to be extremely tough to protect the inner contents of the eye. These functions are governed by its structure at all hierarchical levels. The basic principles of corneal structure and transparency have been known for some time, but in recent years X-ray scattering and other methods have revealed that the details of this structure are far more complex than previously thought and that the intricacy of the arrangement of the collagenous lamellae provides the shape and the mechanical properties of the tissue. At the molecular level, modern technologies and theoretical modelling have started to explain exactly how the collagen fibrils are arranged within the stromal lamellae and how proteoglycans maintain this ultrastructure. In this review we describe the current state of knowledge about the three-dimensional stromal architecture at the microscopic level, and about the control mechanisms at the nanoscopic level that lead to optical transparency.
AI snapshot
Written from the paper’s full text.
TL;DR
This review synthesizes current knowledge of corneal stromal architecture and transparency, emphasizing that transparency arises from collagen fibril uniformity and short-range order rather than lamellar arrangement alone. It integrates X-ray scattering, electron tomography, nonlinear microscopy, and theoretical modelling to explain how proteoglycans and type V collagen regulate fibril spacing and diameter.
Key findings
- The stroma comprises nearly 90% of corneal thickness; the central human cornea has approximately 200 lamellae, with anterior lamellae highly interwoven and posterior lamellae less interlaced. Anterior lamellar insertions into Bowman’s layer average about 19°.
- Transparency depends on narrow collagen fibrils with uniform diameters and restricted centre-to-centre spacing. Fibrils contain about 300–400 triple-helical molecules per cross-section and about 70 microfibrils, with axial periodicity reduced from 67 nm to closer to 65 nm.
- Maurice calculated that independent scattering would leave only about 6% of incoming light to reach the retina; destructive interference from ordered fibrils cancels scattering in all directions except forward. If 20% of fibrils have twice the normal diameter, backward radiation arises and transparency is impaired.
- Type V collagen limits fibril diameter, while proteoglycans maintain interfibrillar spacing. Across over 40 animal species, the volume fraction occupied by hydrated fibrils and interfibrillar GAGs was constant. Human corneal transmittance exceeds 90% between 500 and 1300 nm, reaches 80% at 380 nm, and drops at 1430 and 1950 nm due to water absorption; transmittance decreases outside the central 4 mm.
Methods
- Narrative review of corneal stromal structure and transparency, synthesizing evidence from X-ray scattering, electron tomography, second harmonic generation and other nonlinear microscopy, spectrophotometry, and theoretical modelling.
- Evidence base includes human, bovine, rabbit, chicken embryo, mutant mouse, and comparative data from over 40 animal species, plus unpublished results from the authors’ group.
- Main analysis is qualitative synthesis of structural and optical studies and theoretical models; no systematic review or meta-analysis is described.
Limitations
- Stated in the paper: X-ray scattering cannot directly image lamellae and must infer arrangement from diffraction patterns; it provides bulk averages and cannot resolve adjacent lamellae. Multiple scattering is not fully modelled, and photonic band structure theory has been applied only to a perfect hexagonal lattice. The existence of Dua’s layer/pre-Descemet’s layer remains controversial, and some cited findings are unpublished.
- Evident from the text: as a narrative review, it does not report a systematic search strategy or quantitative synthesis, and it relies substantially on animal models and unpublished or preliminary data rather than new primary experimental data.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
55 of 152 cited sources checked · 32 supported · 1 flagged · accuracy not yet measured
- Interpretationcitation
The decrease in transmittance outside the central 4 mm pre-pupillary cornea is attributed to the increase in fibril radius that occurs in the periphery of the cornea.
“Theoretical calculations of light transmission (Doutch et al., 2008) attributed this to the increase in fibril radius that occurs in the periphery of the cornea (Boote et al., 2003).”
Quote in the paperSubstantial claim2 of 2 sources checked- cites Doutch et al., 2008 source
The Discussion and “Modeling transmission in the human cornea” attribute increased peripheral scattering to larger fibrils, supporting the main attribution. The paper does not establish the claimed central 4 mm boundary: the Discussion calls the prepupillary zone approximately 3 mm in diameter, while the modeling section describes it as extending about 3 mm from the optical center. Its conclusion also identifies a change in refractive-index ratio as a contributor. (LLM, conf=0.86)
Experimental — accuracy not yet measured - cites Boote et al., 2003 source
The Results (Fig. 5 and Table 2, near p. 2944) say fibril diameter remained constant from the corneal center to the limbus, with no significant difference between the prepupillary and peripheral zones. The reported increase occurs across the limbus, not within the peripheral cornea, so this paper contradicts the attributed explanation. (LLM, conf=0.93)
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measured
- Premisecitation
The lamella arrangement plays no significant role in corneal transparency.
“However, it plays no significant role in corneal transparency”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites Meek et al., 2003 source
The Phototherapeutic keratectomy section (p. 9) predicts only a very small loss of light transmission despite poorly organised collagen in a thin layer newly deposited after PTK. That limited finding does not establish that lamellar arrangement plays no significant role in corneal transparency generally; the Direct summation of fields method section (p. 5) says that destroying fibril order increases scattering. (LLM, conf=0.84)
Experimental — accuracy not yet measured
- Premisecitation
There are about 300-400 triple-helical molecules within the cross-section of a corneal collagen fibril, depending on the species.
“There are about 300–400 triple-helical molecules within the cross-section of a fibril, depending on the species (Meek and Leonard, 1993, Holmes and Kadler, 2005)”
Quote in the paperNot a substantial claim1 of 2 sources checked- cites Meek and Leonard, 1993 source
The Results and Discussion (page unavailable) estimate the number of collagen molecules per fibril cross-section and say that this number differs between species. The accessible passage points to Table 3 for the estimates, but our copy does not provide readable table values establishing the claimed range of about 300–400. (LLM, conf=0.82)
Experimental — accuracy not yet measured - cites Holmes and Kadler, 2005 source
- Premisecitation
This network seems to contain collagen fibrils with a larger diameter than those in the central cornea.
“and seems to contain collagen fibrils with a larger diameter to those in the central cornea (Boote et al., 2011).”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites Boote et al., 2011 source
- Premisecitation
Stromal interweaving in the peripheral cornea seems to extend to the deeper posterior lamellae.
“In addition, stromal interweaving in the peripheral cornea seems to extend to the deeper posterior lamellae (Radner et al., 1998, Abass et al., 2015).”
Quote in the paperNot a substantial claim1 of 2 sources checked
- Premisecitation
In the human cornea, there is no orthogonal arrangement between adjacent lamellae, not even in the posterior stroma.
“Both scanning electron microscopy (Radner et al., 1998) and non-linear SHG microscopy (Winkler et al., 2015) have shown that, in the human cornea, there is no orthogonal arrangement between adjacent lamellae (Fig. 1b), not even in the posterior stroma.”
Quote in the paperNot a substantial claim1 of 2 sources checked - Premisecitation
The arrangement of these putative structures seems to correspond with the shear stress distribution in the peripheral cornea.
“The arrangement of these putative structures seem to correspond with the sheer stress distribution in the peripheral cornea (Antony, 2015).”
Quote in the paperSubstantial claim1 of 1 sources checked- cites Antony, 2015 source
The Results and Discussion report that the measured shear-stress profile correlates with the diamond-like structural architecture of the cornea. The paper describes this correlation for the cornea generally, not specifically for the peripheral cornea, so the location in the citing sentence is not established by our copy. (LLM, conf=0.82)
Experimental — accuracy not yet measured
- Premisecitation
This network of collagen lamellae shows mirror symmetry between left and right eyes.
“This network shows mirror symmetry between left and right eyes (Boote et al., 2006)”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites Boote et al., 2006 source
- Premisecitation
In human corneas, the lamellar organisation through the full thickness from limbus-to-limbus has been reconstructed, demonstrating interweaving of anterior lamellae and their bow spring-like insertions in and out of Bowman's layer.
“Also in human corneas, Jester et al. (2010) were able to reconstruct the lamellar organisation through the full thickness of the cornea from limbus-to-limbus. The reconstructions demonstrated the interweaving of the anterior lamellae and their bow spring-like insertions in and out of Bowman's layer (Fig. 1d).”
Quote in the paperSubstantial claim1 of 1 sources checked- cites Jester et al., 2010 source
- Premisecitation
The bow spring-like arrangement of anterior lamellae provides structural support to maintain the shape of the anterior corneal surface.
“and that this bow spring-like arrangement provides structural support to maintain the shape of the anterior corneal surface (Winkler et al., 2013).”
Quote in the paperSubstantial claim1 of 1 sources checked- cites Winkler et al., 2013 source
The Discussion says that interconnected transverse fibers in the anterior stroma likely stabilize corneal shape. It does not describe the anterior lamellae as a bow spring-like arrangement or establish that specific arrangement as the mechanism supporting the anterior surface. (LLM, conf=0.82)
Experimental — accuracy not yet measured
- Premisecitation
Collagen lamellae in the deeper stroma have preferred directions that appear to be close to the inferior-superior and nasal-temporal directions.
“Collagen lamellae in the deeper stroma (Fig. 1a) have preferred directions, which appear to be close to the inferior-superior and nasal-temporal directions (Meek et al., 1987, Aghamohammadzadeh et al., 2004, Abahussin et al., 2009, Kamma-Lorger et al., 2010).”
Quote in the paperSubstantial claim1 of 3 sources checked - Interpretationcitation
It seems likely that alterations in tissue thickness from central cornea to limbus in human corneas are due to an increase in the amount of collagen in the peripheral stroma.
“although water distribution from central cornea to limbus is not known for human corneas, it seems likely that alterations in tissue thickness are due to an increase in the amount of collagen in the peripheral stroma (Aghamohammadzadeh et al., 2004, Boote et al., 2011, Henriksson et al., 2012).”
Quote in the paperNot a substantial claim2 of 3 sources checked - Premisecitation
In the mammalian cornea, the most likely corneal crystallin candidates are aldehyde dehydrogenases, particularly ALDH3A1, first detected in bovine cornea and later confirmed by others.
“In the mammalian cornea, the most likely candidates are aldehyde dehydrogenases, particularly ALDH3A1, that was first detected in the bovine cornea by Holt and Kinoshita (1973) and later confirmed by others (Alexander et al., 1981, Silverman et al., 1981, Chen et al., 2013).”
Quote in the paperNot a substantial claim1 of 3 sources checked- cites Holt and Kinoshita (1973)
- cites Alexander et al., 1981 source
- cites Chen et al., 2013 source
The sections on corneal SLRPs and matrix integrity discuss proteoglycans, collagen organization, and transparency, but not corneal crystallins or aldehyde dehydrogenases. Searches for ALDH3A1, corneal crystallins, and Holt and Kinoshita found no passage addressing the claimed identification or its history. (LLM, conf=0.76)
Experimental — accuracy not yet measured
- Premisecitation
Studies of mutant mice unable to produce necessary amounts of lumican, decorin and biglycan in the cornea confirmed the effect of proteoglycan cores on fibril size.
“These findings were confirmed in studies of mutant mice unable to produce the necessary amount of lumican, decorin and biglycan in the cornea (Chakravarti et al., 1998, Chakravarti et al., 2006, Zhang et al., 2008).”
Quote in the paperSubstantial claim2 of 3 sources checked - Interpretationcitation
It is very difficult to see how a Fibonacci quasi-crystalline fibril arrangement could arise spontaneously in a cornea, especially given non-systematic interactions between collagen fibrils and proteoglycans.
“However, it is very difficult to see how a Fibonacci quasi-crystalline fibril arrangement could arise spontaneously in a cornea, especially in the light of non-systematic interactions between collagen fibrils and proteoglycans (see below – Lewis et al., 2010).”
Quote in the paperSubstantial claim1 of 1 sources checked- cites Lewis et al., 2010 source
- Premisecitation
Keratocytes could contribute up to 15% of the total stromal volume.
“However, we now know that these cells could contribute up to 15% of the total stromal volume (Huang and Meek, 1999)”
Quote in the paperSubstantial claim1 of 1 sources checked- cites Huang and Meek, 1999 source
In the paper’s discussion of water distribution (indexed as Abstract; page unavailable), the authors state that cellular water is approximately 15% of total tissue water at physiological hydration. That is not a measurement of keratocytes as a percentage of total stromal volume, so the cited figure does not support the claim’s denominator or its reference to whole cells. (LLM, conf=0.86)
Experimental — accuracy not yet measured
- Premisecitation
Three-dimensional electron tomographic studies showed that, at least in lumican-deficient mice, the increase in fibril size can be attributed to lateral association of normal sized collagen fibrils.
“Three-dimensional electron tomographic studies (Parfitt, 2011), showed that, at least in the case of lumican-deficient mice, the increase in fibrils size can be attributed to a lateral association of normal sized collagen fibrils.”
Quote in the paperSubstantial claim1 of 1 sources checked- cites Parfitt, 2011
- Premisecitation
Cheng and Pinsky (2013) concluded that electrostatic forces due to proteoglycans coating the fibrils play little part in fibril spacing except when fibrils get very close, at which point these PGs prevent fibril fusion.
“They concluded that electrostatic forces due to the PGs coating the fibrils play little part in fibril spacing except when fibrils get very close, at which point these PGs serve to prevent fibril fusion.”
Quote in the paperSubstantial claim1 of 1 sources checked- cites Cheng and Pinsky (2013) source
The Introduction says a PG-dense coating would have little influence on fibrillar restoring forces until adjacent coatings become close, when a rapidly increasing repulsive force appears. The Discussion says the model assesses how such a coating could prevent fibril aggregation, but explicitly treats the coating as conditional rather than establishing that it exists or prevents fusion in the cornea. (LLM, conf=0.86)
Experimental — accuracy not yet measured
- Premisecitation
The individual proteoglycan core proteins are thought to bind to collagen fibrils at specific axial sites along the collagen fibrils.
“The individual proteoglycan core proteins are thought to bind to collagen fibrils at specific axial sites along the collagen fibrils (Meek et al., 1986, Scott and Haigh, 1988).”
Quote in the paperNot a substantial claim1 of 2 sources checked - Premisecitation
Corneal crystallins are thought to limit backwards scattering by forming a structural unit that promotes short-range order.
“They are thought to limit backwards scattering by forming a structural unit that promotes short-range order (Piatigorsky, 1998).”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites Piatigorsky, 1998 source
Section 5.2 (page unavailable) proposes that abundant proteins in corneal epithelial cells reduce light scattering by minimizing fluctuations in refractive index. The paper attributes short-range ordering to lens crystallins (Introduction) and corneal stromal collagen fibers (Section 4.1), not to a structural unit formed by corneal crystallins. It also does not specify backward scattering. (LLM, conf=0.87)
Experimental — accuracy not yet measured
- Premisecitation
In genetically defective mice with reduced collagen V content, the predicted relationship between collagen V and fibril diameter has been observed.
“This has been seen to be the case when studying genetically defective mouse in which collagen V content was reduced (Hassell and Birk, 2010).”
Quote in the paperSubstantial claim1 of 1 sources checked- cites Hassell and Birk, 2010 source
- Premisecitation
If the endothelial pumping mechanism fails and the cornea swells, regions devoid of collagen fibrils (lakes) impair corneal transparency.
“If this mechanism fails and the cornea swells, regions devoid of collagen fibrils (termed lakes) impair corneal transparency (Clark, 2004, Meek et al., 2003).”
Quote in the paperSubstantial claim1 of 2 sources checked- cites Clark, 2004 source
- cites Meek et al., 2003 source
The Abstract (p. 2) reports collagen-free ‘lakes’ in swollen corneas and says they probably cause additional light scattering; Cornea oedema (p. 6) likewise says lakes could increase scattering. The claim states their effect categorically, and the passages do not establish that failure of the endothelial pumping mechanism causes the swelling. (LLM, conf=0.85)
Experimental — accuracy not yet measured
- Rests on an assumption: If the cornea swells much above its physiological hydration, it begins to scatter significant quantities of light and lose transparency.
- Premisecitation
Endothelial cells in the central 3 mm of the cornea suffer increased age-related oxidative damage compared to cells further out.
“the endothelial cells in the central 3 mm of the cornea suffer increased age-related (probably ultraviolet-induced) oxidative damage compared to cells further out (Mimura and Joyce, 2006, Joyce et al., 2009).”
Quote in the paperNot a substantial claim1 of 2 sources checked- cites Mimura and Joyce, 2006 source
The available passages labeled Abstract contain bibliographic information, not findings about oxidative damage. Searches for central-versus-peripheral damage, the central 3 mm, and ultraviolet exposure found no substantive passage, so the available copy cannot verify this claim. (LLM, conf=0.72)
Experimental — accuracy not yet measured - cites Joyce et al., 2009 source
- Premisecitation
Corneal crystallins change the refractive index of the cell cytoplasm to better match the extracellular matrix and thus eliminate scattering.
“they have a dual role in that they change the refractive index of the cell cytoplasm to better match the extracellular matrix and thus eliminate scattering (Chen et al., 2013).”
Quote in the paperSubstantial claim1 of 1 sources checked- cites Chen et al., 2013 source
The sections on SLRP expression and disrupted matrix integrity discuss corneal transparency and light scattering in relation to stromal collagen organization. Searches for corneal crystallins and refractive-index matching found no passage in our copy addressing the claimed cytoplasmic mechanism. No page numbers were available for these passages. (LLM, conf=0.75)
Experimental — accuracy not yet measured
- Premisecitation
In a study of over 40 animal species, including fish, birds, amphibians and mammals, Meek and Leonard (1993) reported that, despite wide inter-species variation of fibril diameters and centre-to-centre fibril spacings, the volume fraction (proportion of tissue occupied by hydrated fibrils and interfibrillar GAGs) was constant.
“in a study of over 40 animal species, including fish, birds, amphibians and mammals, Meek and Leonard (1993) reported that, even though there was a wide inter-species variation of fibril diameters and centre-to-centre fibril spacings, the volume fraction (i.e. the proportion of the tissue occupied by the hydrated fibrils and hence by the interfibrillar GAGs) was constant.”
Quote in the paperSubstantial claim1 of 1 sources checked- cites Meek and Leonard (1993) source
- Premisecitation
In animals, corneal stem cells can restore tissue transparency.
“In animals, it has previously been demonstrated how corneal stem cells can restore tissue transparency (Du et al., 2009, Syed-Picard et al., 2015).”
Quote in the paperNot a substantial claim1 of 2 sources checked- cites Du et al., 2009
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites Syed-Picard et al., 2015 source
- Findingown data
Our own X-ray scattering observations of the posterior stromal region have revealed no differences in the collagen fibrillar arrangement.
“Although our own observations of this region, using X-ray scattering, have revealed no differences in the collagen fibrillar arrangement”
Quote in the paperNot a substantial claim - Findingcitation
Within the visible spectrum, transmittance decreases outside the central 4 mm pre-pupillary cornea.
“Using spectrophotometry we showed that, within the visible spectrum, transmittance decreases outside the central 4 mm pre-pupillary cornea (Doutch et al., 2007).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites Doutch et al., 2007 source
- Findingreasoning
If 20% of collagen fibrils have a diameter twice the normal size, backward radiation arises.
“The fibrillar arrangement in Fig. 7 is identical to that of Fig. 6, but with 20% of the fibrils having a diameter twice the normal size. This is sufficient for backward radiation to arise (white arrows).”
Quote in the paperSubstantial claim - Findingown data
In a random arrangement of fibrils with short range order, once secondary radiation from all fibrils is added together, backward radiation cancels out completely and only forward radiation remains, carrying the energy lost by the incoming radiation through the cornea.
“In fact, as seen in the figure, once the secondary radiation from all fibrils is added together, backwards radiation cancels out completely and only forward radiation remains, which carries the energy lost by the incoming radiation on through the cornea.”
Quote in the paperSubstantial claim - Findingcitation
In both cows and humans, the highest transmission in the pre-pupillary cornea is slightly displaced from the optical centre.
“Interestingly, in both cows and humans, the highest transmission in the pre-pupillary cornea is slightly displaced from the optical centre, but the functional reason for this is not known (Doutch et al., 2007).”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites Doutch et al., 2007 source
- Findingown data
A corneal model obtained by randomly distributed collagen fibrils has equally good predictive power as the Fibonacci quasi-crystalline model.
“Since a corneal model obtained by randomly distributed collagen fibrils has equally good predictive power (see below and Fig. 12, Fig. 13), such a model, being simpler, should be preferable.”
Quote in the paperSubstantial claim - Findingreasoning
In a fibril arrangement with regions devoid of fibrils, backward radiation cannot be cancelled completely because the missing fibrils cannot contribute to destructive interference.
“If fibrils were present in these regions, they would contribute to cancelling out the overall secondary radiation in the backward direction as in Fig. 6, but since they are missing, they cannot do so and backward radiation cannot be cancelled out completely.”
Quote in the paperSubstantial claim - Findingown data
Modelling of Mie scatter shows that the change in refractive index upon keratocyte activation is sufficient to significantly increase light scattering by these cells.
“Modelling of Mie scatter shows that this change in refractive index is sufficient to significantly increase light scattering by these cells (SJ Gardner, N White, J Albon, C Knupp, CS Kamma-Lorger and KM Meek, unpublished results).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites SJ Gardner, N White, J Albon, C Knupp, CS Kamma-Lorger and KM Meek, unpublished results
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Findingown data
In a computer simulation where collagen fibrils were added at random positions in a confined region with a minimum separation of 56 nm, the appearance of the corneal fibril distribution obtained was remarkably similar to that taken from an electron micrograph of a rabbit cornea, as indicated by radial distribution functions and predicted transmission as a function of wavelength.
“Bearing in mind how simple the simulation was, the appearance of the corneal fibril distribution obtained in this way (Fig. 12a) was remarkably similar to that taken from an electron micrograph of a rabbit cornea (Fig. 12b), as indicated by the calculated radial distribution functions of the fibril positions (insets) and the predicted transmission as a function of wavelength (Fig. 13).”
Quote in the paperSubstantial claim - Premisecitation
The posterior limbus accommodates a circum-corneal annulus in which elastic fibres run parallel to collagen fibres.
“The posterior limbus accommodates a circum-corneal annulus (Fig. 1a) in which elastic fibres run parallel to collagen fibres (Kamma-Lorger et al., 2010).”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites Kamma-Lorger et al., 2010 source
- Premisecitation
Even within the in vivo cornea, on a micron scale, collagen fibrils are probably not straight but have a crimp as in other connective tissues.
“What has often been overlooked is that, even within the in vivo cornea, on a micron scale these fibrils are probably not straight but rather have a crimp as in other connective tissues (Grytz and Meschke, 2009).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites Grytz and Meschke, 2009 source
- Premisecitation
At the centre of the human cornea there are approximately 200 lamellae through the thickness.
“At the centre of the human cornea there are approximately 200 lamellae through the thickness”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites Bergmanson et al., 2005 source
- Premisenone given
The human cornea is composed of five layers: an overlying epithelium, Bowman's layer, the stroma, Descemet's membrane, and the endothelium.
“The human cornea is composed of five layers, an overlying epithelium beneath which is a fibrous meshwork called Bowman's layer. The bulk of the tissue is constituted by the stroma, a collagen-rich central layer that comprises nearly 90% of the thickness of the cornea, and beneath this lies Descemet's membrane which supports the single layer of endothelial cells lining the posterior cornea.”
Quote in the paperNot a substantial claim - Premisecitation
Most anterior lamellae appear to insert into Bowman's layer.
“most appear to insert into Bowman's layer (Morishige et al., 2006)”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites Morishige et al., 2006 source
- Premisecitation
The corneal stroma contains specialised glycoproteins and ions that play an important role in organising the collagen fibrils in order to maintain transparency.
“It also contains specialised glycoproteins (Labat-Robert and Robert, 2012, Wall et al., 1988, Cooper et al., 2006) and, of course, ions that play an important role in organising the collagen fibrils in order to maintain transparency (Kostyuk et al., 2002, Regini et al., 2004).”
Quote in the paperNot a substantial claim0 of 2 sources checked - Premisenone given
The corneal stroma has three primary non-aqueous constituents: collagens, proteoglycans and cells.
“The corneal stroma has three primary non-aqueous constituents: collagens, proteoglycans and cells.”
Quote in the paperNot a substantial claim - Premisenone given
In the bovine cornea, about 30-40 of the molecules in a fibril are type V collagen and the rest are type I.
“Of these molecules, about 30–40 in the bovine cornea are type V collagen, the rest are type I.”
Quote in the paperNot a substantial claim - Premisecitation
The packing density of lamellae is higher in the anterior lamella than in the posterior ones.
“the packing density is higher in the anterior lamella than in the posterior ones (Bergmanson et al., 2005)”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites Bergmanson et al., 2005 source
- Premisenone given
At the microscopic level, the collagen in the stroma is laid down within lamellae.
“It has long been known that, at the microscopic level, the collagen in the stroma is laid down within lamellae.”
Quote in the paperNot a substantial claim - Premisecitation
The mid-stromal lamellae are highly interlaced.
“The mid-stromal lamellae are also highly interlaced (Radner and Mallinger, 2002).”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites Radner and Mallinger, 2002 source
- Premisecitation
The insertion angles of anterior lamellae into Bowman's layer are on average about 19°.
“Quantitative analysis later revealed that the insertion angles were, on average, about 19° (Morishige et al., 2011)”
Quote in the paperSubstantial claim0 of 1 sources checked- cites Morishige et al., 2011 source
- Premisecitation
The anterior lamellae of the human cornea are highly interwoven.
“These anterior lamellae are highly interwoven (Radner et al., 1998)”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites Radner et al., 1998 source
- Interpretationreasoning
The anchoring lamellae may play a role in maintaining the structural integrity of the cornea and sclera.
“We have named them “anchoring lamellae” as they may play a role in maintaining the structural integrity of the cornea and sclera (Fig. 1a).”
Quote in the paperNot a substantial claim - Premisecitation
In human corneas, non-linear microscopy has confirmed that in the posterior stroma, lamellae occur preferentially in orthogonal directions.
“In human corneas, non-linear microscopy has been used to quantify the lamella arrangement at different corneal depths, where the authors could confirm that in the posterior stoma, lamellae occur preferentially in orthogonal directions (Lombardo et al., 2014).”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites Lombardo et al., 2014
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Premisenone given
Moving from the central cornea towards the limbus, the human cornea thickens.
“Moving from the central cornea towards the limbus the human cornea thickens”
Quote in the paperNot a substantial claim - Premisecitation
Hydration is fairly constant from the central cornea to the limbus in the pig and the cow.
“hydration is fairly constant in this direction in the pig and the cow (S. Hayes, unpublished results; Ho et al., 2014)”
Quote in the paperNot a substantial claim0 of 2 sources checked- cites S. Hayes, unpublished results
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites Ho et al., 2014
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Premisecitation
The incorporation of type V collagen into hybrid fibrils plays an important role in limiting the number of molecules that can self-assemble within the fibril.
“The incorporation of type V into hybrid fibrils plays an important role in limiting the number of molecules that can self-assemble within the fibril (Birk et al., 1986).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites Birk et al., 1986
- Premisecitation
The transparency of the corneal epithelium is a result of the homogeneity of the refractive index of all its constituent cells.
“Its transparency is a result of the homogeneity of the refractive index of all its constituent cells (Dohlman, 1971).”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites Dohlman, 1971
- Premisecitation
X-ray scattering has suggested the presence of a network of collagen lamellae that enter the cornea close to the inferior, superior, nasal and temporal positions, and which probably originate in the adjacent sclera.
“X-ray scattering has also suggested the presence of a network of collagen lamellae that enter the cornea close to the inferior, superior, nasal and temporal positions, and which probably originate in the adjacent sclera (Aghamohammadzadeh et al., 2004).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites Aghamohammadzadeh et al., 2004 source
- Interpretationreasoning
The intricacy of the arrangement of the collagenous lamellae provides the shape and the mechanical properties of the corneal tissue.
“the intricacy of the arrangement of the collagenous lamellae provides the shape and the mechanical properties of the tissue”
Quote in the paperSubstantial claim - Premisenone given
The stroma comprises nearly 90% of the thickness of the human cornea.
“The bulk of the tissue is constituted by the stroma, a collagen-rich central layer that comprises nearly 90% of the thickness of the cornea”
Quote in the paperNot a substantial claim - Interpretationreasoning
The constant volume fraction implies that the larger the fibril diameter in a species, the larger the space occupied by the proteoglycans.
“This implies that the larger the fibril diameter in a species, the larger the space occupied by the proteoglycans.”
Quote in the paperSubstantial claim - Interpretationreasoning
Since the only constraint in the simulation, apart from minimum distance, was that fibrils were restricted to a closed region, the 'pressure' exerted by the walls of the region was enough to keep the fibrils close to each other.
“Since the only constraint in the simulation, apart from that of the minimum distance between adjacent fibrils, came from the fact that the fibrils were restricted to be in a closed region, it must be that the “pressure” exerted by the walls of the region was enough to keep the fibrils close to each other.”
Quote in the paperSubstantial claim - Interpretationnone given
For backward scattering to arise from regions devoid of fibrils, these regions have to be separated by distances comparable with the wavelength of the incoming light.
“However, for backward scattering to arise, these regions have to be separated by distances comparable with the wavelength of the incoming light.”
Quote in the paperSubstantial claim - Premisecitation
Interference between scattered light waves from ordered crystalline arrays of collagen fibrils is a mechanism for corneal transparency.
“This lead researchers to look for other mechanisms and specifically to the ideas of interference between scattered light waves from ordered crystalline arrays of collagen fibrils (Maurice, 1957).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites Maurice, 1957 source
- Study design and conductcitation
For quantitative measurement of corneal light transmission, it is important to ensure that the cornea is maintained under tension, because releasing intraocular pressure leads to undulations of the lamellae and increased light scatter.
“It is also important to ensure that the cornea is maintained under tension, as it is usually necessary to remove the cornea from the globe to make the transmission measurement. Otherwise, when the tension due to the intraocular pressure is released, it seems that the resulting undulations of the lamellae lead to increased light scatter (McCally and Farrell, 1977, Kostyuk et al., 2002).”
Quote in the paperSubstantial claim0 of 2 sources checked - Premisecitation
In vitro experiments using purified collagen I and V showed that the type V collagen molecule terminal domain was necessary to regulate the diameters of the formed fibrils.
“In vitro experiments aimed at creating fibrils using purified collagen I and collagen V molecules, showed that the type V collagen molecule terminal domain was necessary to regulate the diameters of the formed fibrils (Birk et al., 1990).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites Birk et al., 1990 source
- Premisecitation
When proteoglycans have their attached glycosaminoglycans removed enzymatically, the surface gap depth increases to about 1.5 nm.
“When proteoglycans have their attached glycosaminoglycans removed enzymatically, the surface gap depth increases to about 1.5 nm (Yamamoto et al., 2002).”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites Yamamoto et al., 2002 source
- Premisecitation
Fibrils reconstituted in the presence of the protein cores of lumican and decorin are significantly thinner than fibrils reconstituted in the absence of the cores.
“Early in vitro studies of reconstituted collagen fibrils, showed that the presence of lumican and decorin protein cores had an effect on the size of the collagen fibrils: fibrils reconstituted in the presence of the protein cores of the proteoglycans were significantly thinner than the fibrils reconstituted in the absence of the cores (Rada et al., 1993).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites Rada et al., 1993 source
- Premisecitation
Confocal microscope studies of corneal wound healing suggest that activation of keratocyte cells could be responsible for the increase in scattering.
“Confocal microscope studies of corneal wound healing suggest that the activation of the keratocyte cells could be responsible for the increase in scattering (Jester et al., 1999, Moller-Pedersen, 2004).”
Quote in the paperSubstantial claim0 of 2 sources checked - Premisecitation
In human corneas, the depth of the grooves in the gaps is about 0.23 nm.
“In human corneas, the depth of the grooves in the gaps is about 0.23 nm (Meller et al., 1997).”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites Meller et al., 1997 source
- Premisenone given
The collagen molecules have left-handed helical polypeptide chains in a right-handed superhelix.
“The collagen molecules have left-handed helical polypeptide chains in a right-handed superhelix.”
Quote in the paperNot a substantial claim - Interpretationreasoning
When the protein cores of proteoglycans are present on the surface of collagen fibrils, their bulk prevents adjacent fibrils from coming into contact and establishing the necessary bonds.
“In practice, this would not happen when the protein cores of the proteoglycans are present on the surface of the collagen fibrils, because their bulk would prevent adjacent fibrils from coming into contact and establish the necessary bonds.”
Quote in the paperSubstantial claim - Interpretationcitation
When any fibril undergoes a dynamic excursion from its lattice position, the electrostatic restoring forces act to restore the fibril.
“When any fibril undergoes a dynamic excursion from its lattice position, the electrostatic restoring forces act to restore the fibril.”
Quote in the paperSubstantial claim - Premisecitation
Müller et al. (2004) modified Maurice's model: collagen fibrils still lie on a perfect hexagonal lattice but are kept in position by proteoglycans linking next nearest fibrils rather than adjacent fibrils.
“In the model by Muller et al., the collagen fibrils still lie on a perfect hexagonal lattice, but they are kept in position by proteoglycans linking next nearest fibrils as opposed to adjacent fibrils as in in the model by Maurice.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites Müller and collaborators (2004)
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Interpretationreasoning
Because no specific attractive forces between collagen fibrils were introduced in the simulation, the attractive forces had to come from elsewhere.
“In fact, no specific attractive forces between the collagen fibrils were introduced in the simulation, which implied that the attractive forces had to come from elsewhere.”
Quote in the paperSubstantial claim - Interpretationreasoning
Theoretical considerations suggest that the wavelength dependence of scattered energy is true for whole corneas in which the fibril arrangement has short range order.
“Theoretical considerations suggest this to be true for whole corneas in which the fibril arrangement has short range order (as in Fig. 7).”
Quote in the paperSubstantial claim - Interpretationreasoning
Any alternative model for the packing of fibrils in the cornea must obey the wavelength dependence of scattered light.
“We should also point out that any alternative model for the packing of fibrils in the cornea must obey this wavelength dependence.”
Quote in the paperSubstantial claim - Premisecitation
Measurements of the refractive index of corneal collagen indicated a significant difference between the collagen and the interstitial matrix.
“but measurements of the refractive index of the corneal collagen eventually indicated a significant difference between the collagen and the interstitial matrix (Aurell and Holmgren, 1953).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites Aurell and Holmgren, 1953 source
- Premisecitation
An endothelium-based pumping mechanism maintains corneal hydration, which would otherwise increase due to the stromal gel pressure.
“An endothelium-based pumping mechanism maintains corneal hydration which would otherwise increase due to the stromal gel pressure (Stiemke et al., 1995).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites Stiemke et al., 1995 source
- Premiseown data
Two drops in infrared transmitted intensity through the cornea at 1430 nm and 1950 nm are caused by water absorption.
“Two drops in infrared transmitted intensity were noted at 1430 nm and 1950 nm which are caused by water absorption (Fig. 3).”
Quote in the paperNot a substantial claim - Interpretationreasoning
Because the intensity of the scattered wave from a fibril depends on the amount of collagen within the fibril (and therefore its radius), perfect backward destructive interference cannot be achieved from collagen fibrils whose diameters are not constant.
“Because the intensity of the scattered wave from a fibril depends on the amount of collagen within the fibril (and therefore its radius), perfect backward destructive interference cannot be achieved from collagen fibrils whose diameters are not constant, as in Fig. 7.”
Quote in the paperSubstantial claim - Interpretationreasoning
Corneal opacity due to this mechanism arises when adjacent fibrils join randomly together to form larger fibrils with varying diameters.
“Corneal opacity due to this mechanism arises when adjacent fibrils join randomly together to form larger fibrils with varying diameters.”
Quote in the paperSubstantial claim - Premisecitation
The two most commonly used techniques to measure corneal transparency ex vivo are tungsten light-based or laser-based bench-top optical systems, or spectrophotometry.
“The two most commonly used techniques to measure corneal transparency ex vivo are tungsten light-based or laser-based bench-top optical systems (Farrell et al., 1973, Christens-Barry et al., 1996, Parekh et al., 2014), or spectrophotometry (Cejka et al., 2010, Doutch et al., 2008).”
Quote in the paperNot a substantial claim0 of 3 sources checked - Interpretationown data
This simulation supported the hypothesis that the appearance of a cornea could be explained by a random deposition of fibrils with an exclusion zone around each one.
“This supported the hypothesis that the appearance of a cornea could be explained by a random deposition of fibrils with an exclusion zone around each one”
Quote in the paperSubstantial claim - Premisecitation
The energy scattered by each fibril when unpolarised light falls on it is inversely proportional to the third or fourth power of the wavelength of the incoming light.
“We should point out that the energy scattered by each fibril when unpolarised light falls on it is inversely proportional to the third (Maurice, 1962) or fourth (Van den Berg and Tan, 1994) power of the wavelength of the incoming light.”
Quote in the paperSubstantial claim0 of 2 sources checked - Interpretationcitation
The repulsive forces between fibrils are due to pressure exerted by water molecules attracted between the fibrils via the Donnan effect.
“The repulsive forces between the fibrils are due to the pressure exerted by water molecules attracted between the fibrils via the Donnan effect.2”
Quote in the paperSubstantial claim - Premisecitation
Between 600 nm and 1000 nm, transmission values above 95% were recorded in the human cornea.
“but, unlike Boettner and Wolter (1962), between 600 nm and 1000 nm, transmission values above 95% were recorded.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites Beems and Van Best, 1990 source
- Interpretationcitation
The λ−3 dependence found in rabbit corneas indicates that the fibril arrangement seen in micrographs, which has short range order, is a very good representation of the fibril arrangement present in corneal lamellae in vivo.
“we can take it as an indication that the fibril arrangement seen in micrographs, which has short range order (Fig. 12b, inset) is a very good representation of the fibril arrangement present in the corneal lamellae in vivo (Farrell et al., 1973).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites Farrell et al., 1973 source
- Premisecitation
UVA transmission decreases almost linearly from the centre to the periphery in all meridians.
“The authors found that UVA transmission decreases almost linearly from the centre to the periphery in all meridians”
Quote in the paperSubstantial claim0 of 1 sources checked- cites Lombardo et al., 2015 source
- Premisecitation
When X-rays pass through the cornea, measuring the angles of the diffracted beams allows the fibril separation to be calculated.
“This is the case, for example, when X-rays (electromagnetic waves characterised by short wavelengths and invisible to the naked eye) pass through the cornea, and by measuring the angles of these so-called diffracted beams, the fibril separation can be calculated (Meek and Quantock, 2001).”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites Meek and Quantock, 2001 source
- Interpretationcitation
The cornea is not opaque because secondary waves from all collagen fibrils interfere with each other so that they cancel out in all directions except the forward direction, allowing the energy of incoming radiation to propagate forward through the cornea.
“The reason why the cornea is not opaque is that, as suggested by Maurice in 1957, the secondary waves from all collagen fibrils interfere with each other in a way that they cancel out in all directions except the forward direction.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites Maurice in 1957 source
- The authors state this as an assumption: The secondary electromagnetic radiation scattered by any collagen fibril does not interact with other fibrils of the cornea but travels undisturbed to the retina.
- Interpretationreasoning
The electrostatic and hydrophobic forces that drive collagen molecules together to form fibrils may be strong enough to guide and maintain the lateral association of two or more fully formed collagen fibrils.
“In general, the electrostatic and hydrophobic forces that drive the collagen molecules together to form fibrils may be strong enough to guide and maintain the lateral association of two or more fully formed collagen fibrils.”
Quote in the paperSubstantial claim - Premisecitation
Experimental measurements from rabbit corneas in the visible spectrum have found a λ−3 dependence for the transmission of the scattered light.
“Since experimental measurements from rabbit corneas in the visible spectrum have found a λ−3 dependence for the transmission of the scattered light (Farrell et al., 1973)”
Quote in the paperSubstantial claim0 of 1 sources checked- cites Farrell et al., 1973 source
- Interpretationreasoning
Without the terminal domains, the amino acid distribution along type V and type I collagen molecules is such that electrostatic and hydrophobic forces drive them to assemble side by side with a 67 nm axial shift and form large heterotypic fibrils.
“In view of this, it seems likely that without the terminal domains, the amino acid distribution along the type V and type I collagen molecules is such that the collagen molecules experience electrostatic and hydrophobic forces that drive them to assemble side by side, with a 67 nm axial shift, and form large heterotypic fibrils.”
Quote in the paperSubstantial claim - Premisecitation
In corneal stroma, type V collagen molecules retain their amino-terminal non-collagenous domain.
“It was also found that in corneal stroma, type V collagen molecules retained their amino-terminal non-collagenous domain.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites Birk et al., 1990 source
- Interpretationreasoning
In cornea, the surface gaps may help to accommodate the non-collagenous extensions of the component type V molecules and thus play a role in limiting fibrillar growth by molecular accretion.
“In cornea, they may help to accommodate the non-collagenous extensions of the component type V molecules and thus play a role in limiting fibrillar growth by molecular accretion (see later).”
Quote in the paperNot a substantial claim - Premisecitation
Synthetic collagen gels used in partial thickness grafts appear to act as temporary scaffolds to allow remodelling of the tissue.
“but at present it appears that these gels are acting as temporary scaffolds to allow remodelling of the tissue.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites Fagerholm et al., 2010 source
- Premisecitation
Clinical trials have been carried out on partial thickness grafts using synthetic collagen gels.
“Currently, trials have been carried out on partial thickness grafts using synthetic collagen gels (Fagerholm et al., 2010)”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites Fagerholm et al., 2010 source
- Classified as probably not a substantial claim. 26
- May combine two claims. 65
- The quote only partly states this claim. 2
Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
PremisecitationThe corneal epithelium is about 53 μm deep and constitutes about 10% of the corneal thickness.
“The corneal epithelium, on the other hand, is about 53 μm deep (Reinstein et al., 2008) and thus constitutes about 10% of the corneal thickness.”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites Reinstein et al., 2008 source
May combine two claims.
PremisecitationSecond harmonic generation imaging can provide qualitative and quantitative information about lamellar organisation within the cornea and has the potential to be used in vivo.
“Over the last decade there has been an upsurge in the use of non-linear microscopy, in particular second harmonic generation imaging, to provide qualitative (Han et al., 2005, Morishige et al., 2006, Teng et al., 2006, Bueno et al., 2011) and quantitative (Mega et al., 2012, Tuer et al., 2012, Ghazaryan et al., 2013) information about the lamellar organisation within the cornea, a technique that,”
Quote in the paperNot a substantial claim3 of 3 sources checked- cites Han et al., 2005 source
- cites Mega et al., 2012 source
The paper’s Abstract describes a method for quantifying collagen-lamellar orientation in corneal SHG images, supporting the quantitative part for which Mega et al. is cited. The experiments used a bovine cornea placed on a microscope cover slip; our copy does not establish the claimed potential for in vivo use. In the printed sentence, the qualitative citations are to other papers. (LLM, conf=0.86)
Experimental — accuracy not yet measured - cites Latour et al., 2012 source
May combine two claims.
PremisecitationThe posterior stroma can swell easily whereas the more interwoven anterior stroma cannot.
“The posterior stroma can swell easily whereas the more interwoven anterior cannot (Müller et al., 2001).”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites Müller et al., 2001 source
Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
PremisecitationAt the nanoscopic level, corneal transparency is defined by the absence of pigments or blood vessels (in most species), and by the structure and organisation of the collagen fibrils within the lamellae.
“and at the nanoscopic level, by the absence of pigments or blood vessels (in most species), and by the structure and organisation of the collagen fibrils within the lamellae (Meek et al., 2003).”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites Meek et al., 2003 source
The discussion of corneal transparency (pp. 2–3) links light transmission to the structure and arrangement of collagen fibrils within lamellae. Our copy does not state that transparency depends on the absence of pigments or blood vessels, including the qualification about most species. (LLM, conf=0.88)
Experimental — accuracy not yet measured
Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
PremisecitationMammalian corneas do not have an orthogonal arrangement of adjacent lamellae, whereas non-mammalian vertebrate corneas share a common orthogonal collagen structural organisation, suggesting a divergent evolutionary background.
“The technique was recently used to show that mammalian corneas do not have an orthogonal arrangement of adjacent lamellae, whereas non-mammalian vertebrate corneas share a common orthogonal collagen structural organisation, which suggests that they have a divergent evolutionary background (Winkler et al., 2015).”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites Winkler et al., 2015 source
May combine two claims.
PremisecitationAcross the anterior stroma, lamellae are highly interwoven and randomly directed when observed en face.
“Across the anterior stroma, lamellae are highly interwoven (Radner et al., 1998) and randomly directed when observed en face (Abahussin et al., 2009).”
Quote in the paperNot a substantial claim1 of 2 sources checkedProbably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationCorneal transparency is defined at the microscopic level by the absence of scatter by corneal cells or by other structures that could cause local changes to the refractive index.
“this property is defined at the microscopic level by the absence of scatter by corneal cells or by other structures that could cause local changes to the refractive index”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites Meek et al., 2003 source
The Direct summation of fields method section (p. 5) links low scattering by corneal cells to their refractive indices, but calls the cells weak scatterers—not non-scatterers—and notes that their nuclei scatter. The discussion on p. 3 also says collagen fibrils scatter light because their refractive index differs from the surrounding material; transparency involves interference of that scattered light. Thus the paper supports the importance of limiting scatter, but not the claimed microscopic absence of it. (LLM, conf=0.84)
Experimental — accuracy not yet measured
May combine two claims.
InterpretationcitationThe cross-linked rope-like structure with alternating twist at each hierarchical level conveys considerable strength to the narrow corneal fibrils, in contrast to the fibrils in the adjacent sclera, which are wider and have a more parallel arrangement of microfibrils.
“This cross-linked rope-like structure with alternating twist at each hierarchical level conveys considerable strength to the narrow corneal fibrils, and is in contrast to the fibrils in the adjacent sclera, which are correspondingly wider and therefore have a more parallel arrangement of microfibrils within them (Yamamoto et al., 2000).”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites Yamamoto et al., 2000 source
Split into 2 atoms — 0 confirmed, 2 partially supported, 0 disputed, 0 misattributed, 0 unverifiable. Expand the claim to see per-atom verdicts.
Experimental — accuracy not yet measured
May combine two claims.
Findingown dataThree-dimensional electron tomographic reconstructions of bovine cornea showed that collagen fibrils were not lying on a perfect hexagonal lattice and that there was nothing systematic in the geometry of connections of adjacent or next nearest collagen fibrils.
“From the reconstructions, it was evident that the collagen fibrils were not laying on a perfect hexagonal lattice, and also that there was nothing systematic in the geometry of the connections of adjacent or next nearest collagen fibrils.”
Quote in the paperSubstantial claim1 of 1 sources checked- cites Lewis et al., 2010 source
Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
PremisecitationFibromodulin plays a major role in development of the peripheral cornea but its presence in the normal cornea is uncertain.
“fibromodulin plays a major role in development of the peripheral cornea but its presence in the normal cornea is uncertain (Chen et al., 2010).”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites Chen et al., 2010 source
The Discussion supports an important role for fibromodulin in peripheral corneal development. But although the Results call its presence in mature corneal stroma controversial, the paper then reports barely detectable levels at P90 and concludes that fibromodulin is not a component of mature corneal stroma. It does not leave its presence in the adult cornea uncertain. (LLM, conf=0.88)
Experimental — accuracy not yet measured
May combine two claims.
PremisecitationMicrofibrils have a right-handed twist within the fibrils and are stabilised by covalent intermolecular and intramolecular crosslinks.
“Microfibrils have a right-handed twist within the fibrils (Orgel et al., 2006), and are stabilised by covalent intermolecular and intramolecular crosslinks (Yamauchi et al., 1996).”
Quote in the paperNot a substantial claim1 of 2 sources checkedProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
PremisecitationDoutch (2009) found that a Fibonacci quasi-crystalline fibril arrangement closely resembles collagen fibril organization seen in micrographs and that the wavelength dependence of its predicted transparency matches the experimental one very closely.
“Doutch found that not only does its appearance closely resemble the collagen fibril organization seen in micrographs, but also that the wavelength dependence of the predicted transparency matches very closely the experimental one.”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites Doutch (2009)
May combine two claims.
PremisecitationThe surface gaps are a primary binding site for dermatan sulphate-containing proteoglycans, which are necessary for preventing adjacent fibrils from fusing together.
“They are also a primary binding site for dermatan sulphate-containing proteoglycans (Scott and Haigh, 1988), which, as we will also see later, are necessary for preventing adjacent fibrils from fusing together (Chen and Birk, 2013).”
Quote in the paperSubstantial claim2 of 2 sources checked- cites Scott and Haigh, 1988 source
- cites Chen and Birk, 2013 source
The section “Instructive roles in collagen fibrillogenesis” (page unavailable) says that proteoglycan glycosaminoglycans extend into the space between fibrils and can influence their spacing and organization. It does not say that dermatan sulphate-containing proteoglycans are necessary to prevent adjacent fibrils from fusing. The surface-binding-site clause is cited to Scott and Haigh, not Chen and Birk, and is not judged here. (LLM, conf=0.84)
Experimental — accuracy not yet measured
May combine two claims.
PremisecitationKeratocytes are regarded as quiescent but can be activated after injury, generating myofibroblast precursors that can persist and cause corneal scarring due to their own opacity and production of fibrotic tissue.
“The keratocytes are regarded as being quiescent but can be activated after injury generating myofibroblast precursors that can sometimes persist and cause corneal scarring due to their own opacity as well as their production of fibrotic tissue (Torreicelli and Wilson, 2014).”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites Torreicelli and Wilson, 2014 source
May combine two claims.
PremisecitationCorneal structural defects of this type are associated with genetic mutations involving proteoglycans, which seem to affect the repulsive forces between adjacent fibrils and allow them to fuse.
“Corneal structural defects of this type are associated, for example, with genetic mutations involving proteoglycans (Chakravarti et al., 1998) which, ultimately, seem to have an effect on the repulsive forces between adjacent fibrils and allow them to fuse together.”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites Chakravarti et al., 1998 source
The Discussion reports corneal opacity in mice with a null mutation of the lumican gene, and its collagen-fibril section describes frequent lateral fusion of fibrils. The paper proposes that proteoglycan core proteins discourage lateral fusion, but it does not identify a change in repulsive forces between adjacent fibrils as the mechanism. (LLM, conf=0.85)
Experimental — accuracy not yet measured
May combine two claims.
FindingcitationUV transmission through the cornea decreases from the centre to the periphery, attributed to a combination of scattering and absorption.
“We found that UV transmission through the cornea decreases from the centre to the periphery, and attributed this to a combination of scattering and absorption (Doutch et al., 2012).”
Quote in the paperSubstantial claim1 of 1 sources checked- cites Doutch et al., 2012 source
May combine two claims.
PremisecitationThe Cheng and Pinsky mechanism operates regardless of the direction of the perturbation and regardless of whether GAG chains are part of a duplex or are independent.
“Their mechanism, illustrated in Fig. 11, operates regardless of the direction of the perturbation and regardless of whether GAG chains are part of a duplex or are independent.”
Quote in the paperSubstantial claim1 of 1 sources checked- cites Cheng and Pinsky (2013) source
May combine two claims.
PremisecitationCheng and Pinsky (2013) concluded that ions attracted by the unbalanced charge on the glycosaminoglycan chains of interfibrillar proteoglycans play a dominant role in keeping fibrils on optimal lattice positions by acting as restoring forces, and that these forces by themselves can reproduce the image distribution of fibrils seen in the electron microscope.
“On the other hand, the ions attracted by the unbalanced charge on the glycosaminoglycan chains of the interfibrillar PGs play a dominant role in keeping the fibrils on optimal lattice positions, by acting as restoring forces, and the authors showed that these, by themselves, can reproduce the image distribution of fibrils seen in the electron microscope.”
Quote in the paperSubstantial claim1 of 1 sources checked- cites Cheng and Pinsky (2013) source
May combine two claims.
InterpretationcitationIn vitro, fibrils formed by collagen I and collagen V are larger than those found in vivo, indicating additional mechanisms such as microfibrillar coiling or collagen-bound disaccharides regulate fibril diameter.
“However, it was noticed that, in vitro, the fibrils formed by collagen I and collagen V are larger than those found in vivo. This indicates that there may be additional mechanisms such as microfibrillar coiling (Raspanti, 2010) or collagen-bound disaccharides (Harding et al., 1980) that regulate fibril diameter.”
Quote in the paperSubstantial claim1 of 2 sources checked- cites Raspanti, 2010 source
- cites Harding et al., 1980
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
May combine two claims.
PremisereasoningBecause both polyanionic charge per unit volume and tissue hydration are constant between species regardless of PG composition, Meek and Leonard proposed a model in which fixed charges on GAGs are synthesised in proportion to total fibrillar collagen (types I and V); the larger the collagen fibrils, the greater the amount of fixed charge in the interfibrillar space, therefore the further apart the
“Because both polyanionic charge per unit volume and tissue hydration are constant between species, regardless of the PG composition (Scott and Bosworth, 1990, Gyi, 1988), they proposed a model in which the fixed charges on GAGs are synthesised in proportion to the total fibrillar collagen (types I and V) (Meek and Leonard, 1993); the larger the collagen fibrils, the greater amount of fixed charge”
Quote in the paperSubstantial claim2 of 3 sources checked- cites Scott and Bosworth, 1990 source
Split into 2 atoms — 0 confirmed, 1 partially supported, 0 disputed, 0 misattributed, 1 unverifiable. Expand the claim to see per-atom verdicts.
Experimental — accuracy not yet measured - cites Gyi, 1988
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites Meek and Leonard, 1993 source
May combine two claims.
PremisecitationIn corneal oedema (bullous keratopathy, Fuch's dystrophy), local decreases in refractive index are caused by pooling of fluid into lakes; the influx of fluid also disrupts fibril organisation and reduces destructive interference of scattered light.
“A similar effect occurs in corneal oedema (bullous keratopathy, Fuch's dystrophy) but in this case there are local decreases in refractive index caused by pooling of fluid into so-called “lakes” (Casadessus et al., 2012) (Fig. 8). The influx of fluid into the stroma also leads to disruption of the fibril organisation and thus to the reduction in destructive interference of scattered light.”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites Casadessus et al., 2012 source
Split into 2 atoms — 1 confirmed, 1 partially supported, 0 disputed, 0 misattributed, 0 unverifiable. Expand the claim to see per-atom verdicts.
Experimental — accuracy not yet measured
May combine two claims.
PremisecitationThe opacity of corneal scars is a result of improper remodelling of the connective tissue matrix; collagen fibrils are wider than normal and poorly ordered in scar tissue.
“On the other hand, the opacity of corneal scars is a result of improper remodelling of the connective tissue matrix; collagen fibrils are wider than normal and poorly ordered in scar tissue (Boote et al., 2013).”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites Boote et al., 2013 source
The Results (Collagen Spatial Organisation) report locally increased fibril diameter and reduced spatial order at the graft margins compared with unwounded corneas. The Discussion links these changes to incomplete remodelling and fibrotic scar tissue, but says they *could be a contributing factor* to visible opacity. The claim states a definite cause for corneal scars generally, beyond what the paper establishes for these graft margins. (LLM, conf=0.88)
Experimental — accuracy not yet measured
May combine two claims.
FindingcitationCurrent work in our group has revealed that many elastic fibres seem to originate in the limbus, forming sheets at the edge of the cornea which then split up and extend as microfibrils, possibly oxytalan or elaunin, across the stroma.
“current work in our group has revealed that many fibres seem to originate in the limbus, forming sheets at the edge of the cornea which then split up and extend as microfibrils, possibly oxytalan or elaunin (Alexander and Garner, 1983), across the stroma (White et al., 2014).”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites White et al., 2014
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
May combine two claims.
Findingown dataIn the human cornea, elastic fibres are present throughout most of the stromal depth but are concentrated below the posterior-most keratocyte layer.
“We have shown in the human cornea that these elastic fibres, though present throughout most of the stromal depth, are concentrated below the posterior-most keratocyte layer (unpublished results).”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
Findingnone givenPreliminary unpublished work by Knupp suggested there may be another type of 'attractive' force acting on the fibrils that would prevent them from drifting apart.
“Recent preliminary unpublished work by Knupp aimed at elucidating the role of keratocytes in corneal fibril deposition suggested that there may be another type of “attractive” force acting on the fibrils that would prevent them from drifting apart.”
Quote in the paperNot a substantial claimThe quote only partly states this claim.
Findingnone givenIn the same reconstructions, the distribution of distances between adjacent fibrils was narrow.
“What was evident, however, was that the distribution of distances between adjacent fibrils was narrow.”
Quote in the paperSubstantial claimMay combine two claims.
Findingown dataThe refractive index of the keratocyte cytoplasm matches that of the stroma as a whole, whereas upon activation the refractive index falls.
“Recent measurements from our group have shown that the refractive index of the keratocyte cytoplasm matches that of the stroma as a whole, whereas, upon activation, the refractive index falls.”
Quote in the paperSubstantial claimMay combine two claims.
Findingown dataFor two collagen fibrils, when the wavelength is smaller than the fibril separation, secondary radiation cancels completely in some directions and reinforces in others, so the resulting secondary waves exist only along distinct directions related to the fibril separation.
“This simple case shows that, if the wavelength is smaller than the fibril separation as depicted, there can be directions in which secondary radiation cancels out completely and others where they reinforce so that the resulting secondary waves exist only along distinct directions which are related to the fibril separation.”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S3 (load-bearing), S4 (based).
Premisenone givenIn a number of corneal pathologies, changes in one or more of the other layers can lead to increased light scattering and consequent loss of corneal transparency.
“in a number of corneal pathologies, changes in one or more of the other layers can lead to increased light scattering and consequent loss of corneal transparency”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
Premisenone givenThe lamellae consist of narrow, parallel collagen fibrils embedded in a proteoglycan-rich hydrated matrix.
“The lamellae have long been known to consist of narrow, parallel collagen fibrils embedded in a proteoglycan-rich hydrated matrix.”
Quote in the paperNot a substantial claimMay combine two claims.
Interpretationown dataThe elastic system may have an important biomechanical role but it is unlikely to influence transparency in the centre of the normal cornea.
“This elastic system may have an important biomechanical role but it is unlikely to influence transparency in the centre of the normal cornea.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationWhen a so-called big bubble is induced during pneumodissection, part of the posterior stroma often adheres to Descemet's membrane, indicating a natural cleavage plane in the stroma about 10 μm above Descemet's membrane.
“when a so-called “big bubble” is induced, part of the posterior stroma often adheres to the Descemet's membrane, and that there is, therefore, a natural cleavage plane in the stroma about 10 μm above Descemet's membrane (Jafarinasab et al., 2010, McKee et al., 2011).”
Quote in the paperSubstantial claim0 of 2 sources checkedProbably not a substantial claim: may not pass S3 (load-bearing).
Premisenone givenIn humans, Bowman's layer and Descemet's membrane together contribute less than 4% to the total corneal thickness.
“in humans, Bowman's layer and Descemet's membrane, both collagenous tissues like the stroma, together contribute less than 4% to the total corneal thickness”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
PremisecitationThe basic ultrastructure of the cornea had been described about 50 years ago and the principles behind corneal transparency were elucidated.
“About 50 years ago the basic ultrastructure had been described (Jakus, 1962) and the principles behind corneal transparency finally elucidated (Maurice, 1957, Hart and Farrell, 1969, Benedek, 1971)”
Quote in the paperNot a substantial claim0 of 3 sources checkedMay combine two claims.
Study design and conductnone givenThe X-ray technique does not allow direct imaging of the lamellar structures; the arrangement of lamellae has to be inferred from the diffraction patterns.
“The X-ray technique does not allow direct imaging of the lamellar structures; the arrangement of lamellae has to be inferred from the diffraction patterns.”
Quote in the paperNot a substantial claimMay combine two claims.
InterpretationcitationCollagen crimp, in combination with elastic fibres in the peripheral cornea, may explain why this region is more pliable and absorbs intraocular pressure fluctuations, thus preventing deformation of the optically important central cornea.
“In fact, collagen crimp, in combination with elastic fibres in the peripheral cornea, may explain why this region is more pliable and absorbs intraocular pressure fluctuations (Boyce et al., 2008), thus preventing deformation of the optically important central cornea.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites Boyce et al., 2008 source
May combine two claims.
PremisecitationCollagen fibrils within the cornea are narrower than in many other connective tissues, and this is an important factor for transparency, which is a function of the diameter.
“Collagen fibrils within the cornea are narrower than in many other connective tissues and this is an important factor for transparency, which is a function of the diameter (Hart and Farrell, 1969).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites Hart and Farrell, 1969 source
May combine two claims.
PremisecitationThere is a distribution of crimp angles in corneal collagen fibrils, which can be altered under mechanical load.
“There is a distribution of crimp angles, which can be altered under mechanical load.”
Quote in the paperSubstantial claimClassified as probably not a substantial claim. May combine two claims.
Premisenone givenThe basic principles of corneal structure and transparency have been known for some time, but recent X-ray scattering and other methods have revealed that the details of this structure are far more complex than previously thought.
“The basic principles of corneal structure and transparency have been known for some time, but in recent years X-ray scattering and other methods have revealed that the details of this structure are far more complex than previously thought”
Quote in the paperSubstantial claimClassified as probably not a substantial claim.
PremisecitationThe tensile strength, defined shape, and optical clarity of the cornea may derive from the arrangement of the constituents of the stroma.
“For nearly a century it has been realised that these properties may derive from the arrangement of the constituents of the stroma (Eisler, 1930, Kolmer and Lauber, 1936).”
Quote in the paperSubstantial claim0 of 2 sources checked- cites Eisler, 1930 source
- cites Kolmer and Lauber, 1936
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
May combine two claims.
PremisecitationHuman corneal lamellae are typically up to 0.2 mm broad and 2 μm thick.
“These structures are of variable thickness, in humans typically up to 0.2 mm broad and 2 μm thick (Polack, 1961, Komai and Ushiki, 1991).”
Quote in the paperNot a substantial claim0 of 2 sources checked- cites Polack, 1961 source
- cites Komai and Ushiki, 1991
May combine two claims.
Study design and conductreasoningX-ray data represent bulk averages throughout the tissue being sampled, so it is not possible to obtain information pertaining to adjacent lamellae using this approach.
“Furthermore, the X-ray data represent bulk averages throughout the tissue being sampled so, for instance, it is not possible to obtain information pertaining to adjacent lamellae using this approach.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationThe molecules within a corneal collagen fibril are arranged axially with the typical 67 nm D-periodic stagger, with gaps between the N- and C-termini of consecutive molecules.
“which are arranged axially with the typical 67 nm D-periodic stagger (Meek and Holmes, 1983) with gaps between the N- and C-termini of consecutive molecules (Fig. 2).”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites Meek and Holmes, 1983 source
May combine two claims.
Premisenone givenThe lamella arrangement within the cornea helps to maintain the overall shape of the tissue and is responsible for some optical properties such as corneal birefringence.
“The lamella arrangement within the cornea helps to maintain the overall shape of the tissue and is also responsible for some optical properties such as corneal birefringence.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing), S4 (based).
Premisenone givenIn most mammals, the cornea is the only tissue requiring considerable tensile strength coupled with a perfectly defined shape and optical clarity.
“In most mammals, the cornea is the only tissue requiring considerable tensile strength coupled with a perfectly defined shape and optical clarity.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
Premisenone givenModern technologies and theoretical modelling have started to explain how collagen fibrils are arranged within stromal lamellae and how proteoglycans maintain this ultrastructure.
“At the molecular level, modern technologies and theoretical modelling have started to explain exactly how the collagen fibrils are arranged within the stromal lamellae and how proteoglycans maintain this ultrastructure.”
Quote in the paperNot a substantial claimMay combine two claims.
Premisenone givenThe posterior lamellae in the central cornea are more hydrated and are believed to have less interlacing, lying on top of each other like the layers in plywood.
“The posterior lamellae in the central cornea are more hydrated and are believed to have less interlacing, lying on top of each other like the layers in plywood.”
Quote in the paperNot a substantial claimMay combine two claims.
InterpretationcitationThe attractive forces are due to proteoglycans that connect two or more fibrils; these proteoglycans undergo thermally driven conformational changes so their glycosaminoglycan chains experience a force that prevents full extension and brings terminal ends and attached fibrils closer together, equivalent to molecular forces in a stretched rubber band.
“The attractive forces are due to those proteoglycans that connect two or more fibrils. These proteoglycans would be subject to thermally driven conformational changes so that their glycosaminoglycan chains will experience a force that prevents them from assuming a fully extended conformation and which brings their terminal ends, and the collagen fibrils attached to them, closer together. These”
Quote in the paperSubstantial claim0 of 1 sources checked- cites Feynman et al., 1963
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
May combine two claims.
InterpretationreasoningA perfect hexagonal lattice is not required for corneal transparency; it is sufficient for the distance between adjacent fibrils to be constrained.
“As it turns out, the requirement of a perfect hexagonal lattice for the arrangement of the collagen fibrils is not a stringent one, in fact, to have a transparent cornea, it is sufficient for the distance between adjacent fibril to be constrained.”
Quote in the paperSubstantial claimMay combine two claims.
PremisecitationPurified type I collagen forms fibrils of varying diameters in vitro, while type V collagen forms small fibrils.
“Both collagen types, when purified, could assemble in vitro to form fibrils, but in this case type I collagen formed fibrils of varying diameters, while type V formed small fibrils.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites Birk et al., 1990 source
Classified as probably not a substantial claim.
PremisecitationStromal cells contain cytoplasmic molecules called corneal crystallins that act in much the same way as crystallins in the lens.
“They postulated that stromal cells contain cytoplasmic molecules called corneal crystallins that act in much the same was as crystallins in the lens.”
Quote in the paperSubstantial claim0 of 2 sources checkedProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
InterpretationreasoningThis suggests there may be another source of attractive forces between fibrils in the cornea which come from the pressure exerted by adjacent lamellae; fibrils at the interface between lamellae would be pushed inwards, creating a cascade effect that would hold all fibrils within any lamella close to each other.
“This suggested that there may be another source of attractive forces between fibrils in the cornea which come from the pressure exerted by the adjacent lamellae. In this case, the fibrils at the interface between lamellae would be pushed inwards, creating a cascade effect that ultimately would hold all fibrils within any lamella close to each other.”
Quote in the paperNot a substantial claimMay combine two claims.
Premisenone givenCorneal collagen fibrils, as the principal load-bearing constituents of the lamellae, have to resist tensile forces due to intraocular pressure and protect inner ocular tissues from external trauma while remaining narrow to allow transparency; these are competing requirements.
“Corneal collagen fibrils, as the principal load-bearing constituents of the lamellae, have to resist the tensile forces due to the intraocular pressure and protect the inner ocular tissues from external trauma while at the same time remaining narrow to allow transparency of the tissue; these are competing requirements.”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S3 (load-bearing), S4 (based).
Premisenone givenThe normal adult human stroma contains four small leucine-rich proteoglycans: decorin, lumican, keratocan and mimecan.
“The normal adult human stroma contains four small leucine-rich proteoglycans: decorin, lumican, keratocan and mimecan.”
Quote in the paperNot a substantial claimMay combine two claims.
InterpretationcitationThis idea is in agreement with the model of Cheng and Pinsky: if collagen fibrils were larger in diameter and the interfibrillar space was constant, the repulsive forces generated by the GAGs and their associated ions would be increased, which would increase swelling pressure and push the fibrils further apart to achieve equilibrium.
“This idea is in agreement with the model of Cheng and Pinsky (Fig. 11); if the collagen fibrils were larger in diameter and the interfibrillar space was constant, the repulsive forces generated by the GAGs and their associated ions would be increased, which would increase the swelling pressure and push the fibrils further apart in order to achieve equilibrium.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationThe gel pressure that causes corneal swelling arises from net electrostatic charges within the stroma, most of which is contributed by the acidic groups of glycosaminoglycans, with another contribution from temporary complexing of free chloride ions to ligands within the stroma.
“The gel pressure that causes this swelling arises from net electrostatic charges within the stroma. Most of the electrostatic charge is contributed by the acidic groups of the glycosaminoglycans. The other contribution to net stromal charge arises from the temporary complexing of free chloride ions to ligands within the stroma (Hodson, 1997).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites Hodson, 1997 source
May combine two claims.
InterpretationreasoningThe distances between adjacent collagen fibrils are a consequence of the balancing of two opposing forces acting on the fibrils brought about by the proteoglycans; equilibrium distance is reached when attractive forces cancel repulsive forces.
“It was therefore proposed that the distances between adjacent collagen fibrils are a consequence of the balancing of two opposing forces acting on the fibrils brought about by the proteoglycans. In this model, both opposing forces depend on the separation between the fibrils, and the equilibrium distance between two fibrils is reached when the attractive forces between them cancel out the rep”
Quote in the paperSubstantial claimMay combine two claims.
InterpretationreasoningIn real corneas, incoming light is scattered by many more fibrils than in the simulations, so the overall loss of intensity becomes significant and corneas with such structural defects exhibit impaired transparency.
“However, in real corneas, the incoming light is scattered by many more fibrils than those shown, so that the overall loss of intensity becomes significant and corneas with such structural defects exhibit impaired transparency.”
Quote in the paperSubstantial claimMay combine two claims.
PremisecitationThere are about 70 microfibrils within each corneal collagen fibril, tilted by about 15° to the fibril long axis, and this reduces the usual 67 nm axial periodicity seen in tendon and sclera to closer to 65 nm.
“There are about 70 microfibrils within each fibril (Holmes and Kadler, 2005) which are tilted by about 15° to the fibril long axis (Holmes et al., 2001) and this reduces the usual 67 nm axial periodicity seen in tendon and sclera, to closer to 65 nm (Meek et al., 1981, Marchini et al., 1986, Yamamoto et al., 2000).”
Quote in the paperNot a substantial claim0 of 3 sources checkedProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
InterpretationcitationThe Cheng and Pinsky mechanism would also be relevant to corneal development and to the establishment of the stromal matrix.
“This mechanism would also be relevant to corneal development and to the establishment of the stromal matrix.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationQualitative assessment of corneal transparency by laying the cornea on text or a grid is simple and quick but can be an extremely insensitive test.
“This technique may be useful for comparative purposes as it is simple and quick, and we have used it ourselves (Mi et al., 2011). However, Maurice (2001) pointed out that this can be an extremely insensitive test”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites Maurice, 2001
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationMany other microscopical techniques reveal the presence of this microfibrillar substructure within corneal collagen fibrils.
“Many other microscopical techniques also reveal the presence of this microfibrillar substructure within corneal collagen fibrils (Meek, 2009).”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites Meek, 2009
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationThe general consensus was that the cornea needed to be optically homogenous to be transparent.
“The transparency of the corneal stroma has been studied since the nineteenth century and the general consensus was that the cornea needed to be optically homogenous to be transparent (Schweigger-Seidel, 1869, Von Fleischl, 1880, Ranvier, 1898).”
Quote in the paperNot a substantial claim0 of 3 sources checked- cites Schweigger-Seidel, 1869
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites Von Fleischl, 1880
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites Ranvier, 1898
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
May combine two claims.
InterpretationreasoningThis dynamic proteoglycan connection model would endow the whole cornea with a less rigid and more fluid overall structure, making it more resilient to deformations and facilitating transport of molecules and nutrients across the cornea.
“This would endow the whole cornea with a less rigid and more fluid overall structure which would make the cornea more resilient to deformations due to external stresses and would facilitate the transport of molecules and nutrients across the cornea.”
Quote in the paperSubstantial claimMay combine two claims.
PremisereasoningOpacities associated with corneal dystrophies (granular, lattice, macular, Schnyder) are caused mostly by different kinds of stromal deposits; such deposits cause local changes in refractive index, and these refractive index discontinuities, if comparable with the wavelength of light, lead to increased light scatter.
“Opacities associated with corneal dystrophies (granular dystrophy, lattice dystrophy, macular dystrophy, Schnyder dystrophy) are caused mostly by different kinds of stromal deposits. Such deposits cause local changes in the refractive index of the stroma, and these refractive index discontinuities, if comparable with the wavelength of light, lead to increased light scatter.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationAt the supra-molecular level, the initial building block is a 4-8 nm wide microfibril with a left-handed twist of the constituent molecules.
“At the supra-molecular level, the initial building block is a 4–8 nm wide microfibril (Baldock et al., 2002) with a left-handed twist of the constituent molecules (Fig. 2).”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites Baldock et al., 2002 source
Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
Premisenone givenBiglycan (containing dermatan sulphate) and fibromodulin (containing keratan sulphate) are two other proteoglycans associated with the cornea.
“Two other proteoglycans associated with the cornea are biglycan (containing dermatan sulphate) and fibromodulin (containing keratan sulphate).”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
PremisecitationModels by Maurice (1962) and Hart and Farrell (1969) proposed that collagen fibrils in the corneal stroma are connected to six adjacent fibrils by proteoglycans at regular axial intervals, and that the defined lengths of the proteoglycans force the fibrils onto a perfect hexagonal lattice, guaranteeing corneal transparency.
“The models they proposed were based essentially on the collagen fibrils in the corneal stroma being connected to six adjacent fibrils by proteoglycans at regular axial intervals. The defined lengths of the proteoglycans would force the fibrils on a perfect hexagonal lattice, which would guarantee corneal transparency.”
Quote in the paperNot a substantial claim0 of 2 sources checkedProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
PremisereasoningDecorin contains dermatan sulphate and chondroitin sulphate, while lumican, keratocan and mimecan contain keratan sulphate GAGs.
“The first contains dermatan sulphate and chondroitin sulphate, while the final three contain keratan sulphate GAGs.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationBoettner and Wolter (1962) found that corneal transmittance rose rapidly from 300 nm, reaching 80% at 380 nm and more than 90% between 500 nm and 1300 nm.
“Boettner and Wolter (1962) found that the corneal transmittance rose rapidly from 300 nm, reaching 80% at 380 nm and more than 90% between 500 nm and 1300 nm.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites Boettner and Wolter, 1962
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
May combine two claims.
PremisereasoningCorneal collagen fibrils have surface dips or grooves in the gap zone compared to the overlap zone, explained by the 4:5 ratio of molecular density in the two zones.
“It appears that fibrils have surface dips or grooves in the gap zone compared to the overlap zone, explained by the 4:5 ratio of molecular density in the two zones.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationThe suggestion that collagen fibrils needed to have the same refractive index as their surroundings was stated specifically by Renault (1889).
“The suggestion that collagen fibrils needed to have the same refractive index as their surroundings was stated specifically by Renault (1889).”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites Renault, 1889
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
May combine two claims.
InterpretationreasoningTwo of the most important structural factors for corneal transparency are the uniformity of the diameters of the collagen fibrils and the restriction in the range of distances between adjacent collagen fibrils.
“Two of the most important structural factors for corneal transparency are the uniformity of the diameters of the collagen fibrils, and the restriction in the range of distances between adjacent collagen fibrils.”
Quote in the paperSubstantial claimMay combine two claims.
PremisecitationCorneal opacity during corneal wound healing, or transitory haze following refractive surgery or corneal cross-linking, is caused by activated corneal keratocytes; once activated, these cells have a lower refractive index than the surrounding connective tissue.
“Corneal opacity during corneal wound healing, or transitory haze following refractive surgery or corneal cross-linking, is caused by activated corneal keratocytes (Connon et al., 2003, Moller-Pedersen, 2004). Once activated, these cells have a lower refractive index than the surrounding connective tissue.”
Quote in the paperNot a substantial claim0 of 2 sources checkedMay combine two claims.
Interpretationown dataAny change in cytoplasmic content when keratocytes transform to myofibroblasts is likely to alter the refractive index, and this would contribute to the increase in light scatter.
“Any change in cytoplasmic content when the keratocytes transform to myofibroblasts is likely to alter the refractive index, and this would then contribute to the increase in light scatter.”
Quote in the paperSubstantial claimMay combine two claims.
PremisecitationCorneal fibrils are a blend of type I and type V collagens, and the collagen V to collagen I ratio is noticeably higher in corneal stroma than in other tissues.
“It was found that corneal fibrils were a blend of type I and type V collagens, but unlike in other tissues, the collagen V to collagen I ratio was noticeably higher in corneal stroma (Birk et al., 1990).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites Birk et al., 1990 source
The quote only partly states this claim.
InterpretationreasoningA fibrillar arrangement with short range order, where any two fibrils cannot be closer than 62 nm, is essential to corneal transparency.
“This type of fibrillar arrangement is said to possess short range order and this property is essential to corneal transparency.”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationBiglycan occurs in the epithelium and in the stroma of some pathological corneas.
“Biglycan occurs in the epithelium and in the stroma of some pathological corneas (Funderburgh et al., 1998)”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites Funderburgh et al., 1998
May combine two claims.
PremisereasoningThe presence of oversized collagen fibrils, probably formed by fibril fusion, is also a major cause of corneal light scatter seen in many mucopolysaccharidoses, though accompanying deposition of stored proteoglycans with cells or within the matrix also contributes.
“The presence of similar oversized collagen fibrils, probably formed by fibril fusion (Fig. 7), is also a major cause of corneal light scatter seen in many of the mucopolysaccharidoses, though there is often accompanying deposition of stored proteoglycans with cells or within the matrix that also contributes.”
Quote in the paperNot a substantial claimMay combine two claims.
InterpretationreasoningHaze or opacity within the cornea can have multiple causes, and it is often incorrect to attribute the light scattering to a single structural change that may be observed within the tissue.
“Thus haze or opacity within the cornea can have multiple causes, and it is often incorrect to attribute the light scattering to a single structural change that may be observed within the tissue.”
Quote in the paperSubstantial claim
The authors state this as an assumption.
The secondary electromagnetic radiation scattered by any collagen fibril does not interact with other fibrils of the cornea but travels undisturbed to the retina.
“The explanation for cornea transparency presented above is based on the approximation that the secondary electromagnetic radiation scattered by any collagen fibril will not interact with other fibrils of the cornea, but will travel undisturbed to the retina.”
The paper relies on this without support.
If the cornea swells much above its physiological hydration, it begins to scatter significant quantities of light and lose transparency.
“If the cornea swells much above its physiological hydration it begins to scatter significant quantities of light and to lose its transparency.”
The paper relies on this without support.
Keratocytes themselves are transparent except for their nuclei.
“Keratocytes themselves are transparent except for their nuclei.”
The paper relies on this without support.
Structural data from real corneas can now be collected using modern techniques such as three-dimensional block face scanning electron microscopy.
“Structural data from real corneas can now be collected using modern techniques such as three-dimensional block face scanning electron microscopy”
The paper relies on this without support.
Modern computers are fast enough for transparency predictions to be obtained by solving Maxwell's equations for the collected data.
“modern computers are fast enough for transparency predictions to be obtained by solving Maxwell's equations for the collected data”
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Corneal transparency arises from constructive interference of visible light due to the relatively ordered arrangement of collagen fibrils in the corneal stroma.
“Corneal transparency arises from constructive interference of visible light due to the relatively ordered arrangement of collagen fibrils in the corneal stroma.”
From Structural control of corneal transparency, refractive power and dynamics (2025) · cites this paper as [4]
The ‘Fibril organisation and transparency’ section says short-range order in stromal collagen fibrils is essential to transparency. It explains the mechanism chiefly as destructive interference that cancels scattered radiation outside the forward direction, allowing light to pass through. The claim captures the role of fibril order and interference but describes the mechanism as constructive interference alone. (LLM, conf=0.83)
Experimental — accuracy not yet measured
Cites
Yee, K. (1966) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.1966.1138693 · Cited by 15,008 · see citing works
The Feynman Lectures on Physics
Feynman, R. P., Leighton, R. B., Sands, M., & Treiman, S. B. (1964) · Physics Today · doi:10.1063/1.3051743 · Cited by 2,944 · see citing works
Corneal Collagen Crosslinking: A Systematic Review
Sorkin, N., & Varssano, D. (2014) · Ophthalmologica · doi:10.1159/000357979 · Cited by 1,918 · see citing works
The structure and transparency of the cornea
Maurice, D. M. (1957) · The Journal of Physiology · doi:10.1113/jphysiol.1957.sp005758 · Cited by 1,129 · see citing works
Microfibrillar structure of type I collagen <i>in situ</i>
Orgel, J. P. R. O., Irving, T. C., Miller, A., & Wess, T. J. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0502718103 · Cited by 930 · see citing works
Theory of Transparency of the Eye
Benedek, G. B. (1971) · Applied Optics · doi:10.1364/ao.10.000459 · Cited by 895 · see citing works
(1962) · Investigative Ophthalmology & Visual Science · Cited by 840 · see citing works
Chakravarti, S., Magnuson, T., Lass, J. H., Jepsen, K. J., LaMantia, C., & Carroll, H. (1998) · The Journal of Cell Biology · doi:10.1083/jcb.141.5.1277 · Cited by 731 · see citing works
(1991) · PubMed · Cited by 678 · see citing works
Birk, D. E., Fitch, J. M., Babiarz, J. P., Doane, K. J., & Linsenmayer, T. F. (1990) · Journal of Cell Science · doi:10.1242/jcs.95.4.649 · Cited by 596 · see citing works
The molecular basis of corneal transparency
Hassell, J. R., & Birk, D. E. (2010) · Experimental Eye Research · doi:10.1016/j.exer.2010.06.021 · Cited by 557 · see citing works
The cellular basis of corneal transparency: evidence for 'corneal crystallins'
Jester, J. V., Moller-Pedersen, T., Huang, J., Sax, C. M., Kays, W. T., Cavangh, H. D., Petroll, W. M., & Piatigorsky, J. (1999) · Journal of Cell Science · doi:10.1242/jcs.112.5.613 · Cited by 503 · see citing works
Human Corneal Anatomy Redefined
Dua, H. S., Faraj, L. A., Said, D. G., Gray, T., & Lowe, J. (2013) · Ophthalmology · doi:10.1016/j.ophtha.2013.01.018 · Cited by 471 · see citing works
The specific architecture of the anterior stroma accounts for maintenance of corneal curvature
Muller, L. J. (2001) · British Journal of Ophthalmology · doi:10.1136/bjo.85.4.437 · Cited by 424 · see citing works
Fagerholm, P., Lagali, N. S., Merrett, K., Jackson, W. B., Munger, R., Liu, Y., Polarek, J. W., Söderqvist, M., & Griffith, M. (2010) · Science Translational Medicine · doi:10.1126/scitranslmed.3001022 · Cited by 420 · see citing works
Reinstein, D. Z., Archer, T. J., Gobbe, M., Silverman, R. H., & Coleman, D. J. (2008) · Journal of Refractive Surgery · doi:10.3928/1081597x-20080601-05 · Cited by 379 · see citing works
The regulatory roles of small leucine‐rich proteoglycans in extracellular matrix assembly
Chen, S., & Birk, D. E. (2013) · The FEBS Journal · doi:10.1111/febs.12136 · Cited by 378 · see citing works
A better way to construct the sunflower head
Vogel, H. (1979) · Mathematical Biosciences · doi:10.1016/0025-5564(79)90080-4 · Cited by 370 · see citing works
THE MUCOPOLYSACCHARIDES OF BOVINE CORNEA
Meyer, K., Linker, A., Davidson, E. A., & Weissmann, B. (1953) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)49203-4 · Cited by 350 · see citing works
Rada, J. A., Cornuet, P. K., & Hassell, J. R. (1993) · Experimental Eye Research · doi:10.1006/exer.1993.1081 · Cited by 345 · see citing works
Hierarchical structures in fibrillar collagens
Ottani, V., Martini, D., Franchi, M., Ruggeri, A., & Raspanti, M. (2002) · Micron · doi:10.1016/s0968-4328(02)00033-1 · Cited by 307 · see citing works
Reinstein, D. Z., Archer, T. J., Gobbé, M., Silverman, R. H., & Coleman, D. J. (2009) · Journal of Refractive Surgery · doi:10.3928/1081597x-20090813-04 · Cited by 299 · see citing works
Second harmonic generation imaging of collagen fibrils in cornea and sclera
Han, M., Giese, G., & Bille, J. F. (2005) · Optics Express · doi:10.1364/opex.13.005791 · Cited by 293 · see citing works
Polarization sensitive optical coherence tomography in the human eye
Pircher, M., Hitzenberger, C. K. F., & Schmidt-Erfurth, U. M. (2011) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2011.06.003 · Cited by 289 · see citing works
Meek, K. M., & Boote, C. (2009) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2009.06.005 · Cited by 248 · see citing works
Self-citationHolmes, D. F., Gilpin, C. J., Baldock, C., Ziese, U., Koster, A. J., & Kadler, K. E. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.111150598 · Cited by 244 · see citing works
Kurƶes Handbuch der Ophthalmologie
Bakker, C., Bartels, M., Behr, C., Best, F., Bing, R., Birch-Hirschfeld, A., Brückner, A., Comberg, W., Cords, R., Cramer, E., et al. (1930) · Springer eBooks · doi:10.1007/978-3-642-92496-5 · Cited by 244 · see citing works
UV absorbance of the human cornea in the 240- to 400-nm range.
Kolozsvári, L., Nógrádi, A., Hopp, B., & Bor, Z. (2002) · PubMed · Cited by 241 · see citing works
Light scattering in the cornea
Hart, R. W., & Farrell, R. A. (1969) · Journal of the Optical Society of America · doi:10.1364/josa.59.000766 · Cited by 237 · see citing works
X-Ray Scattering Used to Map the Preferred Collagen Orientation in the Human Cornea and Limbus
Aghamohammadzadeh, H., Newton, R. H., & Meek, K. M. (2004) · Structure · doi:10.1016/j.str.2004.01.002 · Cited by 233 · see citing works
Self-citationTransparency, swelling and scarring in the corneal stroma
Meek, K. M., Leonard, D. W., Connon, C. J., Dennis, S., & Khan, S. (2003) · Eye · doi:10.1038/sj.eye.6700574 · Cited by 230 · see citing works
Self-citationZhang, G., Chen, S., Goldoni, S., Calder, B. W., Simpson, H. C., Owens, R. T., McQuillan, D. J., Young, M. F., Iozzo, R. V., & Birk, D. E. (2009) · Journal of Biological Chemistry · doi:10.1074/jbc.m806590200 · Cited by 224 · see citing works
Stem Cell Therapy Restores Transparency to Defective Murine Corneas
Du, Y., Carlson, E. C., Funderburgh, M. L., Birk, D. E., Pearlman, E. M., Guo, N., Kao, W. W. ‐., & Funderburgh, J. L. (2009) · Stem Cells · doi:10.1002/stem.91 · Cited by 217 · see citing works
Boote, C., Dennis, S., Newton, R. H., Puri, H., & Meek, K. M. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.03-0131 · Cited by 209 · see citing works
Self-citationNonlinear Optical Macroscopic Assessment of 3-D Corneal Collagen Organization and Axial Biomechanics
Winkler, M., Chai, D., Kriling, S., Nien, C. J., Brown, D. J., Jester, B. E., Juhász, T., & Jester, J. V. (2011) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.11-8070 · Cited by 204 · see citing works
Prelude to corneal tissue engineering – Gaining control of collagen organization
Ruberti, J. W., & Zieske, J. D. (2008) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2008.08.001 · Cited by 194 · see citing works
Full-field deformation of bovine cornea under constrained inflation conditions
Boyce, B. L., Grazier, J. M., Jones, R. E., & Nguyen, T. D. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.06.011 · Cited by 191 · see citing works
Corneal crystallins and the development of cellular transparency
Jester, J. V. (2008) · Seminars in Cell & Developmental Biology · doi:10.1016/j.semcdb.2007.09.015 · Cited by 189 · see citing works
Corneal collagen—its role in maintaining corneal shape and transparency
Meek, K. M. (2009) · Biophysical Reviews · doi:10.1007/s12551-009-0011-x · Cited by 183 · see citing works
Self-citationUltrastructure of the corneal stroma: a comparative study
Meek, K. M., & Leonard, D. W. (1993) · Biophysical Journal · doi:10.1016/s0006-3495(93)81364-x · Cited by 166 · see citing works
Self-citationAbahussin, M., Hayes, S., Knox Cartwright, N. E., Kamma-Lorger, C. S., Khan, Y., Marshall, J., & Meek, K. M. (2009) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.09-3669 · Cited by 162 · see citing works
Self-citationMeek, K. M., Blamires, T., Elliott, G. F., Gyi, T. J., & Nave, C. (1987) · Current Eye Research · doi:10.3109/02713688709034853 · Cited by 161 · see citing works
Self-citationConstitutive modeling of crimped collagen fibrils in soft tissues
Grytz, R., & Meschke, G. (2009) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2008.12.009 · Cited by 160 · see citing works
Gene sharing in lens and cornea: facts and implications
Piatigorsky, J. (1998) · Progress in Retinal and Eye Research · doi:10.1016/s1350-9462(97)00004-9 · Cited by 159 · see citing works
Hayashi, S., Osawa, T., & Tohyama, K. (2002) · Journal of Morphology · doi:10.1002/jmor.10030 · Cited by 155 · see citing works
Noninvasive corneal stromal collagen imaging using two-photon-generated second-harmonic signals
Morishige, N., Petroll, M. W., Nishida, T., Kenney, C. M., & Jester, J. V. (2006) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2006.08.027 · Cited by 154 · see citing works
Interlacing and cross-angle distribution of collagen lamellae in the human cornea
Radner, W., Zehetmayer, M., Aufreiter, R., & Mallinger, R. (1998) · Cornea · doi:10.1097/00003226-199809000-00012 · Cited by 153 · see citing works
Three-dimensional distribution of transverse collagen fibers in the anterior human corneal stroma
Winkler, M., Shoa, G., Xie, Y., Petsche, S. J., Pinsky, P. M., Juhasz, T., Brown, D. J., & Jester, J. V. (2013) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.13-13150 · Cited by 152 · see citing works
Bancelin, S., Aimé, C., Gusachenko, I., Kowalczuk, L., Latour, G., Coradin, T., & Schanne‐Klein, M. (2014) · Nature Communications · doi:10.1038/ncomms5920 · Cited by 151 · see citing works
Replication competence and senescence in central and peripheral human corneal endothelium
Mimura, T., & Joyce, N. C. (2006) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.05-1199 · Cited by 147 · see citing works
History of ocular straylight measurement: A review
Berg, T., Franssen, L., Kruijt, B., & Coppens, J. E. (2012) · Zeitschrift für Medizinische Physik · doi:10.1016/j.zemedi.2012.10.009 · Cited by 143 · see citing works
Multiphoton Autofluorescence and Second-Harmonic Generation Imaging of the Ex Vivo Porcine Eye
Teng, S., Tan, H., Peng, J.-L., Lin, H.-H., Kim, K. H., Lo, W., Sun, Y., Lin, W., Lin, S., Jee, S., et al. (2006) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.04-1520 · Cited by 143 · see citing works
Scott, J. E., & Haigh, M. (1988) · Biochemical Journal · doi:10.1042/bj2530607 · Cited by 140 · see citing works
The use of X-ray scattering techniques to determine corneal ultrastructure
Meek, K. M., & Quantock, A. J. (2001) · Progress in Retinal and Eye Research · doi:10.1016/s1350-9462(00)00016-1 · Cited by 139 · see citing works
Self-citationIn vivo structural imaging of the cornea by polarization-resolved second harmonic microscopy
Latour, G., Gusachenko, I., Kowalczuk, L., Lamarre, I., & Schanne-Klein, M.-C. (2012) · Biomedical Optics Express · doi:10.1364/boe.3.000001 · Cited by 139 · see citing works
Lewis, P. N., Pinali, C., Young, R. D., Meek, K. M., Quantock, A. J., & Knupp, C. (2010) · Structure · doi:10.1016/j.str.2009.11.013 · Cited by 139 · see citing works
Self-citationMapping collagen organization in the human cornea: left and right eyes are structurally distinct
Boote, C., Hayes, S., Abahussin, M., & Meek, K. M. (2006) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.05-0893 · Cited by 137 · see citing works
Self-citationTuer, A., Akens, M. K., Kruglov, S. I., Sandkuijl, D., Wilson, B. C., Whyne, C. M., & Barzda, V. (2012) · Biophysical Journal · doi:10.1016/j.bpj.2012.10.019 · Cited by 136 · see citing works
Müller, L., Pels, E., Schurmans, L. R. H. M., & Vrensen, G. F. J. M. (2003) · Experimental Eye Research · doi:10.1016/s0014-4835(03)00206-9 · Cited by 130 · see citing works
(1986) · PubMed · Cited by 127 · see citing works
Farrell, R. A., McCally, R. L., & Tatham, P. E. R. (1973) · The Journal of Physiology · doi:10.1113/jphysiol.1973.sp010325 · Cited by 126 · see citing works
Cellular and extracellular matrix modulation of corneal stromal opacity
Torricelli, A. A. M., & Wilson, S. E. (2014) · Experimental Eye Research · doi:10.1016/j.exer.2014.09.013 · Cited by 124 · see citing works
Light transmittance of the human cornea from 320 to 700 nm for different ages
Van Den Berg, T. J. T. P., & Tan, K. E. W. P. (1994) · Vision Research · doi:10.1016/0042-6989(94)90146-5 · Cited by 122 · see citing works
Light transmission of the cornea in whole human eyes
Beems, E. M., & Van Best, J. A. (1990) · Experimental Eye Research · doi:10.1016/0014-4835(90)90140-p · Cited by 108 · see citing works
Swelling studies on the cornea and sclera: the effects of pH and ionic strength
Huang, Y., & Meek, K. M. (1999) · Biophysical Journal · doi:10.1016/s0006-3495(99)77013-x · Cited by 106 · see citing works
Self-citationDental pulp stem cells: a new cellular resource for corneal stromal regeneration
Syed-Picard, F. N., Du, Y., Lathrop, K. L., Mann, M. M., Funderburgh, M. L., & Funderburgh, J. L. (2015) · Stem Cells Translational Medicine · doi:10.5966/sctm.2014-0115 · Cited by 106 · see citing works
Lohmann, C. P., Timberlake, G. T., Fitzke, F. W., Gartry, D. S., Muir, M. K., & Marshall, J. (1992) · Journal of Refractive Surgery · doi:10.3928/1081-597x-19920301-03 · Cited by 99 · see citing works
Keratocyte reflectivity and corneal haze
Møller-Pedersen, T. (2004) · Experimental Eye Research · doi:10.1016/s0014-4835(03)00208-2 · Cited by 97 · see citing works
(1962) · PubMed · Cited by 93 · see citing works
Joyce, N. C., Zhu, C. C., & Harris, D. L. (2009) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.08-3007 · Cited by 92 · see citing works
Human cornea and sclera studied by atomic force microscopy
Meller, D., Meller, K., & Peters, K. (1997) · Cell and Tissue Research · doi:10.1007/s004410050798 · Cited by 88 · see citing works
Chen, Y., Thompson, D. C., Koppaka, V., Jester, J. V., & Vasiliou, V. (2012) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2012.10.001 · Cited by 88 · see citing works
Petsche, S. J., & Pinsky, P. M. (2013) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-012-0466-8 · Cited by 87 · see citing works
Wang, J., SIMPSON, T. L., & Fonn, D. (2004) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.04-0096 · Cited by 84 · see citing works
Chakravarti, S., Zhang, G., Chervoneva, I., Roberts, L., & Birk, D. E. (2006) · Developmental Dynamics · doi:10.1002/dvdy.20868 · Cited by 82 · see citing works
Three-dimensional aspects of matrix assembly by cells in the developing cornea
Young, R. D., Knupp, C., Pinali, C., Png, K. M. Y., Ralphs, J. R., Bushby, A. J., Starborg, T., Kadler, K. E., & Quantock, A. J. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1313561110 · Cited by 81 · see citing works
Self-citationÜber mechanisch-funktionelle Strukturen des Auges
Kokott, W. (1938) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/bf01856375 · Cited by 81 · see citing works
Morishige, N., Takagi, Y., Chikama, T.-I., Takahara, A., & Nishida, T. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-5657 · Cited by 80 · see citing works
Zigman, S. (1993) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.1993.tb02972.x · Cited by 79 · see citing works
(1998) · PubMed · Cited by 78 · see citing works
Quantification of Collagen Organization in the Peripheral Human Cornea at Micron-Scale Resolution
Boote, C., Kamma-Lorger, C. S., Hayes, S., Harris, J., Burghammer, M., Hiller, J., Terrill, N. J., & Meek, K. M. (2011) · Biophysical Journal · doi:10.1016/j.bpj.2011.05.029 · Cited by 78 · see citing works
Self-citationTransverse depth-dependent changes in corneal collagen lamellar orientation and distribution
Abass, A., Hayes, S., White, N., Sorensen, T., & Meek, K. M. (2015) · Journal of The Royal Society Interface · doi:10.1098/rsif.2014.0717 · Cited by 78 · see citing works
Self-citationBiophysical aspects of corneal and lenticular transparency
Lerman, S. (1984) · Current Eye Research · doi:10.3109/02713688408997182 · Cited by 76 · see citing works
Scott, J. E., & Bosworth, T. R. (1990) · Biochemical Journal · doi:10.1042/bj2700491 · Cited by 75 · see citing works
Bergmanson, J. P. G., Horne, J., Doughty, M. J., Garcia, M., & Gondo, M. (2005) · Eye & Contact Lens: Science & Clinical Practice · doi:10.1097/01.icl.0000165280.94927.0d · Cited by 75 · see citing works
Ultrastructure of the Posterior Corneal Stroma
Schlötzer-Schrehardt, U. M., Bachmann, B. O., Tourtas, T., Torricelli, A. A. M., Singh, A. D., González, S., Mei, H., Deng, S. X., Wilson, S. E., & Kruse, F. E. (2014) · Ophthalmology · doi:10.1016/j.ophtha.2014.09.037 · Cited by 75 · see citing works
(1971) · PubMed · Cited by 70 · see citing works
Light scattering from the human cornea.
Olsen, T. (1982) · PubMed · Cited by 69 · see citing works
Die Anatomie des menschlichen Auges
Eisler, P. (1930) · Anatomie · Entwicklung · Missbildungen · Vererbung · doi:10.1007/978-3-642-92495-8_1 · Cited by 69 · see citing works
Analysis of Corneal Stroma Organization With Wavefront Optimized Nonlinear Microscopy
Bueno, J. M., Gualda, E. J., & Artal, P. (2011) · Cornea · doi:10.1097/ico.0b013e3182000f94 · Cited by 69 · see citing works
Elastic and precursor fibres in the normal human eye
Alexander, R. A., & Garner, A. (1983) · Experimental Eye Research · doi:10.1016/0014-4835(83)90015-5 · Cited by 68 · see citing works
Polack, F. M. (1961) · American Journal of Ophthalmology · doi:10.1016/0002-9394(61)91794-9 · Cited by 68 · see citing works
Collagen and mature elastic fibre organisation as a function of depth in the human cornea and limbus
Kamma-Lorger, C. S., Boote, C., Hayes, S., Moger, J., Burghammer, M., Knupp, C., Quantock, A. J., Sorensen, T., Di Cola, E., & White, N. (2010) · Journal of Structural Biology · doi:10.1016/j.jsb.2009.11.004 · Cited by 66 · see citing works
Self-citationA Mechanical Model of the Cornea Considering the Crimping Morphology of Collagen Fibrils
Liu, X., Wang, L., Ji, J., Yao, W., Wei, W., Fan, J., Joshi, S., Li, D., & Fan, Y. (2014) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.13-12633 · Cited by 66 · see citing works
Doutch, J., Quantock, A. J., Smith, V. A., & Meek, K. M. (2008) · Biophysical Journal · doi:10.1529/biophysj.108.132316 · Cited by 65 · see citing works
Self-citationThe Effect of Corneal Light Scatter on Vision After Penetrating Keratoplasty
Patel, S. V., McLaren, J. W., Hodge, D. O., & Bourne, W. M. (2008) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2008.07.018 · Cited by 64 · see citing works
Evaluating Corneal Collagen Organization Using High-Resolution Nonlinear Optical Macroscopy
Jester, J. V., Winkler, M., Jester, B. E., Nien, C., Chai, D., & Brown, D. J. (2010) · Eye & Contact Lens: Science & Clinical Practice · doi:10.1097/icl.0b013e3181ee8992 · Cited by 64 · see citing works
YAMAMOTO, S., HASHIZUME, H., HITOMI, J., SHIGENO, M., SAWAGUCHI, S., ABE, H., & USHIKI, T. (2000) · Archives of Histology and Cytology · doi:10.1679/aohc.63.127 · Cited by 63 · see citing works
Direct summation of fields for light scattering by fibrils with applications to normal corneas
Freund, D., McCally, R. L., & Farrell, R. A. (1986) · Applied Optics · doi:10.1364/ao.25.002739 · Cited by 63 · see citing works
Interaction of ultraviolet light with the cornea: clinical implications for corneal crosslinking
Lombardo, M., Pucci, G., Barberi, R., & Lombardo, G. (2015) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2014.12.013 · Cited by 62 · see citing works
Dua, H. S., Faraj, L. A., Branch, M. J., Yeung, A. M.-H., Elalfy, M., Said, D. G., Gray, T. B., & Lowe, J. S. (2014) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2013-304593 · Cited by 62 · see citing works
Isolation and characterization of BCP-54, the major soluble protein of bovine cornea
Alexander, R. J. (1981) · Experimental Eye Research · doi:10.1016/0014-4835(81)90009-9 · Cited by 60 · see citing works
Fibromodulin regulates collagen fibrillogenesis during peripheral corneal development
Chen, S., Oldberg, A., Chakravarti, S., & Birk, D. E. (2010) · Developmental Dynamics · doi:10.1002/dvdy.22216 · Cited by 60 · see citing works
Marchini, M., Morocutti, M., Ruggeri, A., Koch, M. H. J., Bigi, A., & Roveri, N. (1986) · Connective Tissue Research · doi:10.3109/03008208609001985 · Cited by 59 · see citing works
Light scatter from the central human cornea
Smith, G. T. H., Brown, N. A., & Shun-Shin, G. A. (1990) · Eye · doi:10.1038/eye.1990.81 · Cited by 59 · see citing works
Interlacing of collagen lamellae in the midstroma of the human cornea
Radner, W., & Mallinger, R. (2002) · Cornea · doi:10.1097/00003226-200208000-00013 · Cited by 58 · see citing works
Dissection plane in deep anterior lamellar keratoplasty using the big-bubble technique
Jafarinasab, M. R., Rahmati-Kamel, M., Kanavi, M. R., & Feizi, S. (2010) · Cornea · doi:10.1097/ico.0b013e3181ba7016 · Cited by 57 · see citing works
Mechanisms of self-organization for the collagen fibril lattice in the human cornea
Cheng, X., & Pinsky, P. M. (2013) · Journal of The Royal Society Interface · doi:10.1098/rsif.2013.0512 · Cited by 53 · see citing works
Quantification of lamellar orientation in corneal collagen using second harmonic generation images
Mega, Y., Robitaille, M., Zareian, R., McLean, J., Ruberti, J., & DiMarzio, C. (2012) · Optics Letters · doi:10.1364/ol.37.003312 · Cited by 52 · see citing works
Hodson, S. A. (1997) · Progress in Retinal and Eye Research · doi:10.1016/s1350-9462(96)00023-7 · Cited by 51 · see citing works
On the metachromatic staining of the corneal tissue and some observations on its transparency
Aurell, G., & Holmgren, H. (1953) · Acta Ophthalmologica · doi:10.1111/j.1755-3768.1953.tb02213.x · Cited by 50 · see citing works
Ultraviolet light transmission through the human corneal stroma is reduced in the periphery
Doutch, J. J., Quantock, A. J., Joyce, N. C., & Meek, K. M. (2012) · Biophysical Journal · doi:10.1016/j.bpj.2012.02.023 · Cited by 50 · see citing works
Self-citationA comparative study of vertebrate corneal structure: the evolution of a refractive lens
Winkler, M., Shoa, G., Tran, S. T., Xie, Y., Thomasy, S., Raghunathan, V. K., Murphy, C., Brown, D. J., & Jester, J. V. (2015) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.15-16584 · Cited by 50 · see citing works
Objective Measurement of Backscattered Light from the Anterior and Posterior Cornea In Vivo
Patel, S. V., Winter, E. J., McLaren, J. W., & Bourne, W. M. (2006) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.06-0767 · Cited by 49 · see citing works
Ho, L. T. Y., Harris, A. M., Tanioka, H., Yagi, N., Kinoshita, S., Caterson, B., Quantock, A. J., Young, R. D., & Meek, K. M. (2014) · Matrix Biology · doi:10.1016/j.matbio.2014.06.004 · Cited by 48 · see citing works
Self-citationInterpretation of the meridional X-ray diffraction pattern from collagen fibrils in corneal stroma
Meek, K. M., Elliott, G. F., Sayers, Z., Whitburn, S. B., & Koch, M. H. J. (1981) · Journal of Molecular Biology · doi:10.1016/0022-2836(81)90482-4 · Cited by 48 · see citing works
Self-citationTissue and species specificity of BCP 54, the major soluble protein of bovine cornea
Silverman, B., Alexander, R. J., & Henley, W. L. (1981) · Experimental Eye Research · doi:10.1016/s0014-4835(81)80078-4 · Cited by 47 · see citing works
A synchrotron X-ray diffraction study of bovine cornea stained with cupromeronic blue
Meek, K. M., Elliott, G. F., & Nave, C. (1986) · Collagen and Related Research · doi:10.1016/s0174-173x(86)80026-7 · Cited by 46 · see citing works
Self-citationCross-linking and the molecular packing of corneal collagen
Yamauchi, M., Chandler, G. S., Tanzawa, H., & Katz, E. P. (1996) · Biochemical and Biophysical Research Communications · doi:10.1006/bbrc.1996.0229 · Cited by 45 · see citing works
McKee, H. D., Irion, L. C. D., Carley, F. M., Jhanji, V., & Brahma, A. K. (2011) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2011-300360 · Cited by 44 · see citing works
Kostyuk, O., Nalovina, O., Mubard, T. M., Regini, J. W., Meek, K. M., Quantock, A. J., Elliott, G. F., & Hodson, S. A. (2002) · The Journal of Physiology · doi:10.1113/jphysiol.2002.021527 · Cited by 41 · see citing works
Self-citationA Lattice Model for Computing the Transmissivity of the Cornea and Sclera
Ameen, D. B., Bishop, M. F., & McMullen, T. (1998) · Biophysical Journal · doi:10.1016/s0006-3495(98)77697-0 · Cited by 38 · see citing works
Corneal transmission in whole human eyes
van Best, J. A., Bollemeijer, J.-G., & Sterk, C. C. (1988) · Experimental Eye Research · doi:10.1016/s0014-4835(88)80062-9 · Cited by 37 · see citing works
(1973) · PubMed · Cited by 36 · see citing works
Order and disorder in the transparent media of the eye
Clark, J. I. (2004) · Experimental Eye Research · doi:10.1016/j.exer.2003.10.008 · Cited by 36 · see citing works
Jester, J. V., Lee, Y. G., Li, J., Chakravarti, S., Paul, J. A., Petroll, W. M., & Cavanagh, H. D. (2001) · Vision Research · doi:10.1016/s0042-6989(00)00222-4 · Cited by 36 · see citing works
Analysis of collagen fiber domain organization by Fourier second harmonic generation microscopy
Ghazaryan, A. A., Tsai, H. F., Hayrapetyan, G. R., Chen, W., Chen, Y., Jeong, M. Y., Kim, C., Chen, S., & Dong, C. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.3.031105 · Cited by 36 · see citing works
Connon, C. J., Marshall, J., Patmore, A. L., Brahma, & Meek, K. M. (2003) · Journal of Refractive Surgery · doi:10.3928/1081-597x-20030501-09 · Cited by 35 · see citing works
Self-citationObservation of Human Corneal and Scleral Collagen Fibrils by Atomic Force Microscopy
Yamamoto, S. (2000) · Japanese Journal of Ophthalmology · doi:10.1016/s0021-5155(00)00156-8 · Cited by 35 · see citing works
The Role of Dermatopontin in the Stromal Organization of the Cornea
Cooper, L. J., Bentley, A. J., Nieduszynski, I. A., Talabani, S., Thomson, A., Utani, A., Shinkai, H., Fullwood, N. J., & Brown, G. M. (2006) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.05-1426 · Cited by 35 · see citing works
Observation of human corneal and scleral collagen fibrils by atomic force microscopy
Yamamoto, S. (2002) · Japanese Journal of Ophthalmology · doi:10.1016/s0021-5155(02)00558-0 · Cited by 33 · see citing works
Renaut, J. (1893) · Biblioteca Digital (Real Academia Nacional de Medicina) · Cited by 31 · see citing works
Rozema, J. J., Trau, R., Verbruggen, K. H. M., & Tassignon, M. (2011) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2011.03.043 · Cited by 30 · see citing works
The precision of lateral size control in the assembly of corneal collagen fibrils
Holmes, D. F., & Kadler, K. E. (2005) · Journal of Molecular Biology · doi:10.1016/j.jmb.2004.10.078 · Cited by 30 · see citing works
Mi, S., Dooley, E. P., Albon, J., Boulton, M. E., Meek, K. M., & Kamma‐Lorger, C. S. (2010) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2010.07.028 · Cited by 27 · see citing works
Self-citationBaldock, C., Gilpin, C. J., Koster, A. J., Ziese, U., Kadler, K. E., Kielty, C. M., & Holmes, D. F. (2002) · Journal of Structural Biology · doi:10.1016/s1047-8477(02)00028-x · Cited by 27 · see citing works
A portable device for measuring donor corneal transparency in eye banks
Parekh, M., Ferrari, S., Ruzza, A., Pugliese, M., Ponzin, D., & Salvalaio, G. (2014) · Cell and Tissue Banking · doi:10.1007/s10561-013-9372-2 · Cited by 25 · see citing works
Clinical physiology of the cornea
Maurice, D. M. (1962) · International Ophthalmology Clinics · doi:10.1097/00004397-196210000-00002 · Cited by 25 · see citing works
Imaging shear stress distribution and evaluating the stress concentration factor of the human eye
Joseph Antony, S. (2015) · Scientific Reports · doi:10.1038/srep08899 · Cited by 24 · see citing works
Spatial distribution of corneal light scattering after corneal collagen crosslinking
Rehnman, J. B., Janbaz, C. C., Behndig, A., & Lindén, C. (2011) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2011.05.028 · Cited by 22 · see citing works
Boote, C., Dooley, E. P., Gardner, S. J., Kamma-Lorger, C. S., Hayes, S., Nielsen, K., Hjortdal, J., Sorensen, T., Terrill, N. J., & Meek, K. M. (2013) · PLoS ONE · doi:10.1371/journal.pone.0068166 · Cited by 21 · see citing works
Self-citationInterpretation of the electron microscopical appearance of collagen fibrils from corneal stroma
Meek, K. M., & Holmes, D. F. (1983) · International Journal of Biological Macromolecules · doi:10.1016/0141-8130(83)90073-9 · Cited by 19 · see citing works
Self-citationThe Ordering of Corneal Collagen Fibrils with Increasing Ionic Strength
Regini, J. W., Elliott, G. F., & Hodson, S. A. (2004) · Journal of Molecular Biology · doi:10.1016/j.jmb.2003.12.001 · Cited by 19 · see citing works
An explanation for the central to peripheral thickness variation in the mouse cornea
Henriksson, J. T., Bron, A. J., & Bergmanson, J. P. (2012) · Clinical & Experimental Ophthalmology · doi:10.1111/j.1442-9071.2011.02652.x · Cited by 19 · see citing works
Spatial mapping of polarized light transmission in the central rabbit cornea
CHRISTENS-BARRY, W. A., GREEN, W. J., CONNOLLY, P. J., FARRELL, R. A., & MCCALLY, R. L. (1996) · Experimental Eye Research · doi:10.1006/exer.1996.0076 · Cited by 18 · see citing works
Fifty years of structural glycoproteins
Labat‐Robert, J., & Robert, L. (2012) · Pathologie Biologie · doi:10.1016/j.patbio.2011.11.010 · Cited by 17 · see citing works
The establishment and maintenance of corneal transparency
Stiernke, M. (1995) · Progress in Retinal and Eye Research · doi:10.1016/1350-9462(93)e0011-r · Cited by 17 · see citing works
Evidence of a Discrete Axial Structure in Unimodal Collagen Fibrils
Raspanti, M., Reguzzoni, M., Protasoni, M., & Martini, D. (2011) · Biomacromolecules · doi:10.1021/bm201314e · Cited by 16 · see citing works
A brief history of proteoglycans
Yanagishita, M. (1993) · Cellular and Molecular Life Sciences · doi:10.1007/bf01923581 · Cited by 16 · see citing works
Casadessus, O., Georges, G., Lamoine, L. S., Deumié, C., & Hoffart, L. (2012) · Biomedical Optics Express · doi:10.1364/boe.3.001793 · Cited by 13 · see citing works
Forward Scattering Properties of Corneal Haze
Brouwere, D. D., GINIS, H. S., Kymionis, G. D., Naoumidi, I. I., & Pallikaris, I. G. (2008) · Optometry and Vision Science · doi:10.1097/opx.0b013e31818527b4 · Cited by 13 · see citing works
The influence of various toxic effects on the cornea and changes in corneal light transmission
Čejka, Č., Ardan, T., Širc, J., Michálek, J., Brùnová, B., & Cejkova, J. (2010) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-010-1438-2 · Cited by 12 · see citing works
Narrow angle light scatter in rabbit corneas after excimer laser surface ablation
GINIS, H. S., Pentari, I., Brouwere, D. D., Bouzoukis, D. I., Naoumidi, I. I., & Pallikaris, I. G. (2009) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2009.00649.x · Cited by 10 · see citing works
On the Presence of Elastic Fibres in the Cornea.
Jh, M. (1906) · Europe PMC (PubMed Central) · Cited by 9 · see citing works
Wall, R. S., ELLIOTT, G. F., Gyi, T. J., Meek, K. M., & Branford-White, C. J. (1988) · Bioscience Reports · doi:10.1007/bf01128974 · Cited by 8 · see citing works
Self-citationIntraocular straylight screening in medical testing centres for driver licence holders in Spain
Michael, R., Barraquer, R. I., Rodríguez, J. C. A., Picado, J. T. I., Jubal, J. S. I., González-Luque, J. C., & van den Berg, T. J. T. P. (2010) · Journal of Optometry · doi:10.1016/s1888-4296(10)70015-7 · Cited by 8 · see citing works
Effect of transcorneal pressure on small-angle light scattering from rabbit cornea
McCally, R. L., & Farrell, R. A. (1977) · Polymer · doi:10.1016/0032-3861(77)90159-8 · Cited by 8 · see citing works
Different architectures of collagen fibrils enforce different fibrillogenesis mechanisms
Raspanti, M. (2010) · Journal of Biomedical Science and Engineering · doi:10.4236/jbise.2010.312152 · Cited by 5 · see citing works
Corneal stroma collagen order determined by polarization sensitive second harmonic microscopy
Lombardo, G., Merino, D., Loza‐Álvarez, P., Lombardo, M., & imaging, I. M. O. (2014) · Investigative Ophthalmology & Visual Science · Cited by 2 · see citing works
<title>Changes in visible light transmission across the corneal stroma</title>
Doutch, J., Quantock, A. J., & Meek, K. M. (2007) · SPIE Proceedings · doi:10.1117/12.740957 · Cited by 2 · see citing works
Self-citation(2011) · UPT. Syiah Kuala University Library (Syiah Kuala University) · Cited by 1 · see citing works
(2009) · ORCA Online Research @Cardiff (Cardiff University) · Cited by 1 · see citing works
Optical-fibre apparatus for quantitative measurement of corneal transparency variation
Barbaro, V., Bartolini, P., Guercio, M. D., & Rispoli, E. (1988) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442270 · Cited by 1 · see citing works
Hoffart, L., Casadessus, O., Georges, G., Siozade, L., & Deumié, C. (2012) · Acta Ophthalmologica · doi:10.1111/j.1755-3768.2012.4284.x · Cited by 1 · see citing works
A comparison of the structure of the corneal stroma in a variety of animal species.
Gyi, T. (1988) · Europe PMC (PubMed Central) · Cited by 1 · see citing works
Hoffart, L. (2013) · Acta Ophthalmologica · doi:10.1111/j.1755-3768.2013.1664.x · Cited by 1 · see citing works
Intraocular straylight screening in medical testing centres for driver licence holders in Spain
MICHAEL, R., BERG, T. V. D., & BARRAQUER, R. (2009) · Acta Ophthalmologica · doi:10.1111/j.1755-3768.2009.3245.x
Flagged first, then by citations
Research works printed but not linked: 12
- Dohlman, 1971, The function of the corneal epithelium in health and disease, Invest. Ophthalmol., 10, 383
- Feynman, 1963, vol. 1
- Harding, 1980, Corneal collagen: a review, Colloq. Int. Cent. Rech. Sci. Natl., 287, 51
- Kolmer, 1936, Handb. Der mikr, Anat. Des. Menschen (v. Möllend.), III, 2
- Maurice, 2001, Graft transparency is in the eye of the beholder, Invest. Ophthalmol. Vis. Sci., S282
- Meyer, 1948, Mucopolysaccharides and mucoids of ocular tissues, vol. 2, 71
- Ranvier, 1898, Influence histogénétique d’une forme antérieure, à propos de la regeneration de la membrane de Descemet, C. R. Acad. Sci. (Paris), 126, 23
- Rispoli, 1978, Apparecchiatura a fibre ottiche per la misura oggettiva della variazione di trasparenza corneale, Boll. Ocul., 55, 63
- Virchow, 1905, vol. 1, 1
- Von Fleischl, 1880, vol. 3, 47
- Weiner, 1912, Allgemeine Sätze űber die Dielektrizitätskonstanten der Mischkörper, Abh. Sachs. Ges. Akad. Wiss. Math. Phys. Kl., 6, 574
- White, 2014, 3D structural studies of the cornea, Ophthalmic Physiol. Opt., 34, 693
Cited by
Sorted by citations
Anatomy of cornea and ocular surface
Sridhar, M. (2018) · Indian Journal of Ophthalmology · doi:10.4103/ijo.ijo_646_17 · Cited by 627 · see citing works
3D bioprinting of a corneal stroma equivalent
Isaacson, A., Swioklo, S., & Connon, C. J. (2018) · Experimental Eye Research · doi:10.1016/j.exer.2018.05.010 · Cited by 424 · see citing works
Myofibroblast transdifferentiation: The dark force in ocular wound healing and fibrosis
Shu, D. Y., & Lovicu, F. J. (2017) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2017.08.001 · Cited by 391 · see citing works
Sorkio, A., Koch, L., Koivusalo, L., Deiwick, A., Miettinen, S., Chichkov, B. N., & Skottman, H. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.04.034 · Cited by 383 · see citing works
Than, A., Liu, C., Chang, H., Duong, P. K., Cheung, C. M. G., Xu, C., Wang, X., & Chen, P. (2018) · Nature Communications · doi:10.1038/s41467-018-06981-w · Cited by 347 · see citing works
Corneal nerves in health and disease
Al-Aqaba, M. A., Dhillon, V. K., Mohammed, I., Said, D. G., & Dua, H. S. (2019) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2019.05.003 · Cited by 305 · see citing works
Print Me An Organ! Why We Are Not There Yet
Ng, W. L., Chua, C. K., & Shen, Y. (2019) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2019.101145 · Cited by 292 · see citing works
Specialty Tough Hydrogels and their Biomedical Applications
Fuchs, S., Shariati, K., & Ma, M.-L. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201901396 · Cited by 240 · see citing works
Composition, structure and function of the corneal stroma
Espana, E. M., & Birk, D. E. (2020) · Experimental Eye Research · doi:10.1016/j.exer.2020.108137 · Cited by 248 · see citing works
Rizwan, M., Peh, G. S. L., Ang, H.-P., Lwin, N. C., Adnan, K., Mehta, J. S., Tan, W. S., & Yim, E. K. F. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.12.026 · Cited by 233 · see citing works
Ocular delivery of proteins and peptides: Challenges and novel formulation approaches
Mandal, A., Pal, D., Agrahari, V., Trinh, H. M., Joseph, M. A., & Mitra, A. K. (2018) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2018.01.008 · Cited by 224 · see citing works
Corneal stromal repair and regeneration
Mohan, R. R., Kempuraj, D., D’Souza, S., & Ghosh, A. (2022) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2022.101090 · Cited by 213 · see citing works
Koivusalo, L., Kauppila, M., Samanta, S., Parihar, V. S., Ilmarinen, T., Miettinen, S., Oommen, O. P., & Skottman, H. (2019) · Biomaterials · doi:10.1016/j.biomaterials.2019.119516 · Cited by 212 · see citing works
Kim, H., Jang, J., Park, J., Lee, K., Lee, S., Lee, D.-M., Kim, K. H., Kim, H. K., & Cho, D. (2019) · Biofabrication · doi:10.1088/1758-5090/ab1a8b · Cited by 202 · see citing works
Complex mechanics of the heterogeneous extracellular matrix in cancer
Malandrino, A., Mak, M., Kamm, R. D., & Moeendarbary, E. (2018) · Extreme Mechanics Letters · doi:10.1016/j.eml.2018.02.003 · Cited by 192 · see citing works
Corneal stromal wound healing: Major regulators and therapeutic targets
Kamil, S., & Mohan, R. R. (2020) · The Ocular Surface · doi:10.1016/j.jtos.2020.10.006 · Cited by 192 · see citing works
Corneal Repair and Regeneration: Current Concepts and Future Directions
Mobaraki, M., Abbasi, R., Vandchali, S. O., Ghaffari, M. S., Moztarzadeh, F., & Mozafari, M. (2019) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2019.00135 · Cited by 180 · see citing works
Designing Scaffolds for Corneal Regeneration
Ahearne, M., Fernández‐Pérez, J., Masterton, S., Madden, P. W., & Bhattacharjee, P. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201908996 · Cited by 174 · see citing works
Yang, C., Nguyen, D. D., & Lai, J. (2023) · Advanced Science · doi:10.1002/advs.202302174 · Cited by 168 · see citing works
Regenerative therapy for the Cornea
Kumar, A., Yun, H., Funderburgh, M. L., & Du, Y. (2021) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2021.101011 · Cited by 162 · see citing works
Corneal injury: Clinical and molecular aspects
Barrientez, B., Nicholas, S. E., Whelchel, A. E., Sharif, R., Hjortdal, J., & Karamichos, D. (2019) · Experimental Eye Research · doi:10.1016/j.exer.2019.107709 · Cited by 156 · see citing works
Navas, A., Magaña‐Guerrero, F. S., Domínguez-López, A., Chávez-García, C., Partido, G., Graue-Hernández, E. O., García, F. J. S., & Garfias, Y. (2018) · Stem Cells Translational Medicine · doi:10.1002/sctm.18-0042 · Cited by 143 · see citing works
Bioprinting of Collagen: Considerations, Potentials, and Applications
Lee, J. M., Suen, S. K. Q., Ng, W. L., Cheung, W. L., & Yeong, W. Y. (2020) · Macromolecular Bioscience · doi:10.1002/mabi.202000280 · Cited by 143 · see citing works
Pathogenesis of Keratoconus: The intriguing therapeutic potential of Prolactin-inducible protein
Sharif, R., Bak‐Nielsen, S., Hjortdal, J., & Karamichos, D. (2018) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2018.05.002 · Cited by 129 · see citing works
Yang, W., Meyers, M. A., & Ritchie, R. O. (2019) · Progress in Materials Science · doi:10.1016/j.pmatsci.2019.01.002 · Cited by 125 · see citing works
Natural Biomaterials for Corneal Tissue Engineering, Repair, and Regeneration
Palchesko, R. N., Carrasquilla, S. D., & Feinberg, A. W. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201701434 · Cited by 115 · see citing works
Current Trends and Future Perspective of Mesenchymal Stem Cells and Exosomes in Corneal Diseases
Mansoor, H., Ong, H. S., Riau, A. K., Stanzel, T. P., Mehta, J. S., & Yam, G. H. (2019) · International Journal of Molecular Sciences · doi:10.3390/ijms20122853 · Cited by 114 · see citing works
Alternatives to eye bank native tissue for corneal stromal replacement
Brunette, I., Roberts, C. J., Vidal, F., Harissi‐Dagher, M., Lachaîne, J., Sheardown, H. D., Durr, G. M., Proulx, S., & Griffith, M. (2017) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2017.04.002 · Cited by 111 · see citing works
Liposomes as vehicles for topical ophthalmic drug delivery and ocular surface protection
López-Cano, J. J., González-Cela-Casamayor, M. A., Andrés‐Guerrero, V., Herrero‐Vanrell, R., & Molina-Martínez, I. T. (2021) · Expert Opinion on Drug Delivery · doi:10.1080/17425247.2021.1872542 · Cited by 115 · see citing works
Ng, W. L., Goh, M. H., Yeong, W. Y., & Naing, M. W. (2018) · Biomaterials Science · doi:10.1039/c7bm01015j · Cited by 111 · see citing works
Engineering Complex Anisotropic Scaffolds beyond Simply Uniaxial Alignment for Tissue Engineering
Xing, J., Liu, N., Xu, N., Chen, W., & Xing, D. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202110676 · Cited by 108 · see citing works
Ismail, E. H., & Paravina, R. D. (2021) · Journal of Esthetic and Restorative Dentistry · doi:10.1111/jerd.12843 · Cited by 105 · see citing works
Mechanisms of Collagen Crosslinking in Diabetes and Keratoconus
McKay, T. B., Priyadarsini, S., & Karamichos, D. (2019) · Cells · doi:10.3390/cells8101239 · Cited by 103 · see citing works
Supercritical Carbon Dioxide-Assisted Decellularization of Aorta and Cornea
Guler, S., Aslan, B., Hosseinian, P., & Aydın, H. M. (2017) · Tissue Engineering Part C Methods · doi:10.1089/ten.tec.2017.0090 · Cited by 101 · see citing works
3D bioprinting for artificial cornea: Challenges and perspectives
Zhang, B., Xue, Q., Li, J., Ma, L., Yao, Y., Ye, H., Cui, Z., & Yang, H. (2019) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2019.05.002 · Cited by 100 · see citing works
Dou, S., Wang, Q., Zhang, B., Wei, C., Wang, H., Liu, T., Duan, H., Jiang, H., Liu, M., Qi, X., et al. (2022) · Cell Discovery · doi:10.1038/s41421-022-00397-z · Cited by 100 · see citing works
Pitre, J. J., Kirby, M. A., Li, D. S., Shen, T. T., Wang, R. K., O’Donnell, M., & Pelivanov, I. (2020) · Scientific Reports · doi:10.1038/s41598-020-69909-9 · Cited by 96 · see citing works
Structurally anisotropic hydrogels for tissue engineering
Khuu, N., Kheiri, S., & Kumacheva, E. (2021) · Trends in Chemistry · doi:10.1016/j.trechm.2021.09.009 · Cited by 91 · see citing works
Mörö, A., Samanta, S., Honkamäki, L., Rangasami, V. K., Puistola, P., Kauppila, M., Narkilahti, S., Miettinen, S., Oommen, O. P., & Skottman, H. (2022) · Biofabrication · doi:10.1088/1758-5090/acab34 · Cited by 92 · see citing works
Structuring of Hydrogels across Multiple Length Scales for Biomedical Applications
Cooke, M. E., Jones, S. W., ter Horst, B., Moiemen, N. S., Snow, M., Chouhan, G., Hill, L. J., Esmaeli, M., Moakes, R. J. A., Holton, J., et al. (2018) · Advanced Materials · doi:10.1002/adma.201705013 · Cited by 91 · see citing works
Transparent silk/gelatin methacrylate (GelMA) fibrillar film for corneal regeneration
Farasatkia, A., Kharaziha, M., ASHRAFIZADEH, F., & Salehi, S. (2020) · Materials Science and Engineering C · doi:10.1016/j.msec.2020.111744 · Cited by 89 · see citing works
The hierarchical response of human corneal collagen to load
Bell, J. S., Hayes, S., Whitford, C., Sánchez-Weatherby, J., Shebanova, O. N., Vergari, C., Winlove, C. P., Terrill, N. J., Sørensen, T. L.-M., Elsheikh, A., et al. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.11.015 · Cited by 86 · see citing works
Self-citationXeroudaki, M., Thangavelu, M., Lennikov, A., Ratnayake, A., Bisevac, J., Petrovski, G., Fagerholm, P., Rafat, M., & Lagali, N. (2020) · Scientific Reports · doi:10.1038/s41598-020-73730-9 · Cited by 86 · see citing works
BCLA CLEAR - Anatomy and physiology of the anterior eye
Downie, L. E., Bandlitz, S., Bergmanson, J. P. G., Craig, J. P., Dutta, D., Maldonado‐Codina, C., Ngo, W., Siddireddy, J. S., & Wolffsohn, J. S. (2021) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2021.02.009 · Cited by 85 · see citing works
Fernández‐Pérez, J., Kador, K. E., Lynch, A. P., & Ahearne, M. (2019) · Materials Science and Engineering C · doi:10.1016/j.msec.2019.110415 · Cited by 84 · see citing works
Mechanistic investigations of diabetic ocular surface diseases
Zhou, Q., Yang, L., Wang, Q., Li, Y., Wei, C., & Xie, L. (2022) · Frontiers in Endocrinology · doi:10.3389/fendo.2022.1079541 · Cited by 81 · see citing works
Datta, P., Vyas, V., Dhara, S., Chowdhury, A. R., & Barui, A. (2019) · Journal of Bionic Engineering · doi:10.1007/s42235-019-0101-9 · Cited by 78 · see citing works
Koivusalo, L., Karvinen, J., Sorsa, E., Jönkkäri, I., Väliaho, J., Kallio, P. J., Ilmarinen, T., Miettinen, S., Skottman, H., & Kellomäki, M. (2017) · Materials Science and Engineering C · doi:10.1016/j.msec.2017.12.013 · Cited by 75 · see citing works
Corneal Endothelial Cells Over the Past Decade: Are We Missing the Mark(er)?
den Bogerd, B. V., Zakaria, N., Adam, B., Matthyssen, S., Koppen, C., & Dhubhghaill, S. N. (2019) · Translational Vision Science & Technology · doi:10.1167/tvst.8.6.13 · Cited by 75 · see citing works
Prospects and Challenges of Translational Corneal Bioprinting
Fuest, M., Yam, G. H., Mehta, J. S., & Campos, D. F. D. (2020) · Bioengineering · doi:10.3390/bioengineering7030071 · Cited by 76 · see citing works
Bioactive hierarchical silk fibers created by bioinspired self-assembly
Fan, L., Li, J., Cai, Z., & Wang, X. (2021) · Nature Communications · doi:10.1038/s41467-021-22673-4 · Cited by 74 · see citing works
Wu, J., Yun, Z., Song, W., Yu, T., Xue, W., Liu, Q., & Sun, X. (2024) · Theranostics · doi:10.7150/thno.89493 · Cited by 74 · see citing works
Mercatelli, R., Mattana, S., Capozzoli, L., Ratto, F., Rossi, F., Pini, R., Fioretto, D., Pavone, F. S., Caponi, S., & Cicchi, R. (2019) · Communications Biology · doi:10.1038/s42003-019-0357-y · Cited by 70 · see citing works
Confocal air-coupled ultrasonic optical coherence elastography probe for quantitative biomechanics
Zvietcovich, F., Nair, A. G., Ambekar, Y. S., Singh, M., Aglyamov, S. R., Twa, M. D., & Larin, K. V. (2020) · Optics Letters · doi:10.1364/ol.410593 · Cited by 69 · see citing works
Hsu, C., Li, Y., Jian, H., Harroun, S. G., Wei, S., Ravindranath, R., Lai, J., Huang, C., & Chang, H. (2018) · Nanoscale · doi:10.1039/c8nr00800k · Cited by 67 · see citing works
3D printing in Ophthalmology: From medical implants to personalised medicine
Tan, G., Ioannou, N., Mathew, E., Tagalakis, A. D., Lamprou, D. A., & Yu‐Wai‐Man, C. (2022) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2022.122094 · Cited by 67 · see citing works
Electrospun GelMA fibers and p(HEMA) matrix composite for corneal tissue engineering
Arica, T. A., Güzelgülgen, M., Yıldız, A. A., & Demir, M. M. (2020) · Materials Science and Engineering C · doi:10.1016/j.msec.2020.111720 · Cited by 65 · see citing works
Successful development and clinical translation of a novel anterior lamellar artificial cornea
Rico‐Sánchez, L., Garzón, I. J., González‐Andrades, M., Ruiz‐García, A., Punzano, M., Lizana-Moreno, A. M., Muñoz‐Ávila, J. I., Sánchez‐Quevedo, M. D. C., Martínez‐Atienza, J., Lopez‐Navas, L., et al. (2019) · Journal of Tissue Engineering and Regenerative Medicine · doi:10.1002/term.2951 · Cited by 65 · see citing works
Integrated 3D bioprinting-based geometry-control strategy for fabricating corneal substitutes
Zhang, B., Xue, Q., Hu, H., Yu, M., Gao, L., Luo, Y., Li, Y., Li, J., Ma, L., Yao, Y., et al. (2019) · Journal of Zhejiang University SCIENCE B · doi:10.1631/jzus.b1900190 · Cited by 64 · see citing works
3D printed artificial cornea for corneal stromal transplantation
Ulağ, S., Ilhan, E., Şahin, A., Karademir-Yilmaz, B., Kalaskar, D. M., Ekren, N., Kılıç, O., Oktar, F. N., & Gündüz, O. (2020) · European Polymer Journal · doi:10.1016/j.eurpolymj.2020.109744 · Cited by 62 · see citing works
Kumar, P., Satyam, A., Cigognini, D., Pandit, A. S., & Zeugolis, D. I. (2016) · Journal of Tissue Engineering and Regenerative Medicine · doi:10.1002/term.2283 · Cited by 61 · see citing works
Integrins: An Important Link between Angiogenesis, Inflammation and Eye Diseases
Mrugacz, M., Bryl, A., Falkowski, M., & Zorena, K. (2021) · Cells · doi:10.3390/cells10071703 · Cited by 57 · see citing works
Bhogal, M. S., Lwin, C. N., Seah, X.-Y., Peh, G. S. L., & Mehta, J. S. (2017) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.17-22106 · Cited by 57 · see citing works
Nanotechnology in regenerative ophthalmology
Sahle, F. F., Kim, S., Niloy, K. K., Tahia, F., Fili, C. V., Cooper, E., Hamilton, D. J., & Lowe, T. L. (2019) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2019.10.006 · Cited by 55 · see citing works
Dua, H. S., Faraj, L. A., Kenawy, M. B., Al-Taan, S. L. M., Elalfy, M., Katamish, T., & Said, D. G. (2017) · Acta Ophthalmologica · doi:10.1111/aos.13460 · Cited by 55 · see citing works
Protectively Decellularized Porcine Cornea versus Human Donor Cornea for Lamellar Transplantation
Shi, W., Zhou, Q., Gao, H., Li, S., Dong, M., Wang, T., Jia, Y., Dong, C., Wang, X., Guo, Z., et al. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201902491 · Cited by 55 · see citing works
3D in vitro corneal models: A review of current technologies
Shiju, T. M., de Oliveira, R. C., & Wilson, S. E. (2020) · Experimental Eye Research · doi:10.1016/j.exer.2020.108213 · Cited by 53 · see citing works
Two-Year Refractive Outcomes After Descemet Membrane Endothelial Keratoplasty
van Dijk, K., Rodríguez‐Calvo‐de‐Mora, M., Esch, H. V., Frank, L. E., Dapena, I., Baydoun, L., Oellerich, S., & Melles, G. R. J. (2016) · Cornea · doi:10.1097/ico.0000000000001022 · Cited by 54 · see citing works
Collagen cross-linking impact on keratoconus extracellular matrix
Sharif, R., Fowler, B., & Karamichos, D. (2018) · PLoS ONE · doi:10.1371/journal.pone.0200704 · Cited by 54 · see citing works
3D bioprinting of corneal models: A review of the current state and future outlook
Balters, L., & Reichl, S. (2023) · Journal of Tissue Engineering · doi:10.1177/20417314231197793 · Cited by 53 · see citing works
Giri, B. R., Jakka, D., Sandoval, M. A., Kulkarni, V. R., & Bao, Q. (2024) · Pharmaceutics · doi:10.3390/pharmaceutics16101325 · Cited by 57 · see citing works
Mesenchymal Stem Cells and Exosomes: A Novel Therapeutic Approach for Corneal Diseases
Bhujel, B., Oh, S., Kim, C., Yoon, Y.-J., Kim, Y.-J., Chung, H.-S., Ye, E., Lee, H., & Kim, J. Y. (2023) · International Journal of Molecular Sciences · doi:10.3390/ijms241310917 · Cited by 52 · see citing works
High-Resolution Bioprinting of Recombinant Human Collagen Type III
Gibney, R., Patterson, J., & Ferraris, E. (2021) · Polymers · doi:10.3390/polym13172973 · Cited by 51 · see citing works
Dendrimers in Corneal Drug Delivery: Recent Developments and Translational Opportunities
Dhull, A., Yu, C., Wilmoth, A. H., Chen, M., Sharma, A., & Yiu, S. C. (2023) · Pharmaceutics · doi:10.3390/pharmaceutics15061591 · Cited by 51 · see citing works
Yam, G. H., Fuest, M., Zhou, L., Liu, Y., Deng, L., Chan, A. S.-Y., Ong, H. S., Khor, W., Ang, M., & Mehta, J. S. (2019) · Scientific Reports · doi:10.1038/s41598-019-39182-6 · Cited by 51 · see citing works
Sharifi, R., Yang, Y., Adibnia, Y., Dohlman, C. H., Chodosh, J., & Gonzalez-Andrades, M. (2019) · Scientific Reports · doi:10.1038/s41598-018-38342-4 · Cited by 51 · see citing works
Han, K., Chang, J., & Azar, D. T. (2019) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.18-26277 · Cited by 51 · see citing works
Regenerative capacity of the corneal transition zone for endothelial cell therapy
Sie, N. M., Yam, G. H., Soh, Y. Q., Lovatt, M., Dhaliwal, D. K., Kocaba, V., & Mehta, J. S. (2020) · Stem Cell Research & Therapy · doi:10.1186/s13287-020-02046-2 · Cited by 51 · see citing works
Yang, B., Jan, N., Brazile, B. L., Voorhees, A. P., Lathrop, K. L., & Sigal, I. A. (2018) · Journal of Biophotonics · doi:10.1002/jbio.201700356 · Cited by 51 · see citing works
In vivo microscopic and optical coherence tomography classification of neurotrophic keratopathy
Mastropasqua, L., Nubile, M., Lanzini, M., Calienno, R., & Dua, H. S. (2018) · Journal of Cellular Physiology · doi:10.1002/jcp.27345 · Cited by 50 · see citing works
Thermo-Gelling Dendronized Chitosans as Biomimetic Scaffolds for Corneal Tissue Engineering
Feng, L., Liu, R., Zhang, X., Li, J., Zhu, L., Li, Z., Li, W., & Zhang, A. (2021) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.1c16087 · Cited by 50 · see citing works
Inhibition of matrix metalloproteinase-9 for the treatment of dry eye syndrome; a review study
Shoari, A., Kanavi, M. R., & Rasaee, M. J. (2021) · Experimental Eye Research · doi:10.1016/j.exer.2021.108523 · Cited by 49 · see citing works
Squishy matters – Corneal mechanobiology in health and disease
Thomasy, S. M., Leonard, B. C., Greiner, M. A., Skeie, J. M., & Raghunathan, V. K. (2024) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2023.101234 · Cited by 49 · see citing works
de Redín, I. L., Boiero, C., Recalde, S., Agüeros, M., Allemandi, D. A., Llabot, J. M., García‐Layana, A., & Irache, J. M. (2019) · Experimental Eye Research · doi:10.1016/j.exer.2019.107697 · Cited by 49 · see citing works
Quantitative structural imaging of keratoconic corneas using polarization-resolved SHG microscopy
Raoux, C., Schmeltz, M., Bied, M., Alnawaiseh, M., Hansen, U. J., Latour, G., & Schanne‐Klein, M. (2021) · Biomedical Optics Express · doi:10.1364/boe.426145 · Cited by 48 · see citing works
Raoux, C., Chessel, A., Mahou, P., Latour, G., & Schanne‐Klein, M. (2023) · Light Science & Applications · doi:10.1038/s41377-023-01224-0 · Cited by 48 · see citing works
Wnt Signaling Is Required for the Maintenance of Human Limbal Stem/Progenitor Cells In Vitro
González, S., Oh, D., Baclagon, E., Zheng, J., & Deng, S. X. (2019) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.18-25740 · Cited by 48 · see citing works
Decorin regulates collagen fibrillogenesis during corneal wound healing in mouse in vivo
Gupta, S., Buyank, F., Sinha, N. R., Grant, D. G., Sinha, P. R., Iozzo, R. V., Chaurasia, S. S., & Mohan, R. R. (2022) · Experimental Eye Research · doi:10.1016/j.exer.2022.108933 · Cited by 47 · see citing works
Arabpour, Z., Baradaran‐Rafii, A., Lotfibakhshaiesh, N., Ai, J., Ebrahimi‐Barough, S., Malekabadi, H. E., Nazeri, N., Vaez, A., Salehi, M., Sefat, F., et al. (2019) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.36742 · Cited by 47 · see citing works
Pham, T. L., & Bazán, H. E. P. (2020) · Journal of Lipid Research · doi:10.1194/jlr.tr120000954 · Cited by 47 · see citing works
The progress in corneal translational medicine
Hancox, Z., Keshel, S. H., Yousaf, S., Saeinasab, M., Shahbazi, M.-A., & Sefat, F. (2020) · Biomaterials Science · doi:10.1039/d0bm01209b · Cited by 46 · see citing works
Structural control of corneal transparency, refractive power and dynamics
Meek, K. M., Knupp, C., Lewis, P. N., Morgan, S. R., & Hayes, S. (2025) · Eye · doi:10.1038/s41433-024-02969-7 · Cited by 45 · see citing works
Self-citationExtracellular Vesicles in Corneal Fibrosis/Scarring
Yeung, V., Boychev, N., Farhat, W., Ntentakis, D. P., Hutcheon, A. E. K., Ross, A. E., & Ciolino, J. B. (2022) · International Journal of Molecular Sciences · doi:10.3390/ijms23115921 · Cited by 44 · see citing works
Multi‐Functional Gelatin‐Dithiolane Hydrogels for Tissue Engineering
Asim, S., Tuftee, C., Qureshi, A. T., Callaghan, R., Geary, M. L., Santra, M., Pal, V., Namlı, İ., Yam, G. H., Ozbolat, I. T., et al. (2024) · Advanced Functional Materials · doi:10.1002/adfm.202407522 · Cited by 44 · see citing works
Small leucine-rich repeat proteoglycans in corneal inflammation and wound healing
Frikeche, J., Maiti, G., & Chakravarti, S. (2016) · Experimental Eye Research · doi:10.1016/j.exer.2016.08.015 · Cited by 44 · see citing works
A Review of the Emerging Role of Silk for the Treatment of the Eye
Tran, S. H., WILSON, C. G., & Seib, F. P. (2018) · Pharmaceutical Research · doi:10.1007/s11095-018-2534-y · Cited by 44 · see citing works
Endogenous retinoic acid signaling is required for maintenance and regeneration of cornea
Kumar, S., Dollé, P., Ghyselinck, N. B., & Duester, G. (2016) · Experimental Eye Research · doi:10.1016/j.exer.2016.11.009 · Cited by 44 · see citing works
Effect of substrate topography on the regulation of human corneal stromal cells
Bhattacharjee, P., Cavanagh, B., & Ahearne, M. (2020) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2020.110971 · Cited by 43 · see citing works
Beeken, L. J., Ting, D. S. J., & Sidney, L. E. (2020) · Stem Cells Translational Medicine · doi:10.1002/sctm.20-0118 · Cited by 42 · see citing works
Zvietcovich, F., Nair, A. G., Singh, M., Aglyamov, S. R., Twa, M. D., & Larin, K. V. (2020) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.61.13.7 · Cited by 43 · see citing works
- Authors
- Meek, K. M., & Knupp, C.
- Affiliations
- Cardiff University (GB)
- Corresponding author
- Meek, Keith M.
- Venue
- Progress in Retinal and Eye Research
- Publisher
- Elsevier BV
- Published
- 2015-11
- Volume
- 49
- Pages
- 1-16
- ISSN
- 1350-9462 (ISSN-L)
- PMC
- PMC4655862
- OpenAlex
- W1954007937
- Semantic Scholar
- 3bb35dcc7f7012bba80682a274c794b4fcefef47
- Cited by
- 853
- References
- 166
- Citations by year
- 2026: 104 · 2025: 109 · 2024: 101 · 2023: 94 · 2022: 99 · 2021: 88 · 2020: 87 · 2019: 75 · 2018: 45 · 2017: 32 · 2016: 17 · 2015: 1 · 2013: 1
- FWCI
- 5.05
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Locations
- Progress in Retinal and Eye Research (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- ORCA Online Research @Cardiff (Cardiff University) (acceptedVersion)
- Funders
- MRC Programme (503626)
- Diamond Light Source
- ESRF
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Corneal surgery and disorders
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Corneal Surgery and Treatments
- Physical Sciences › Materials Science › Biomaterials › Collagen: Extraction and Characterization
- Keywords
- corneal stroma, corneal transparency, collagen fibrils, collagen lamellae, proteoglycans, corneal ultrastructure, optical transmittance, corneal refractive index
- MeSH terms
- Collagen, Cornea, Corneal Stroma, Crystallins, Humans, Microscopy, Electron, Proteoglycans, Extracellular Matrix Proteins
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Claims read by deepseek-v4.1-flash under definition version 3 (extract-v3) on 2026-11-02.
Classified by jev-1.13-20260917 (gold-guideline-v0.2) on 2026-11-02.
Cited sources are checked by gpt-6-sol.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review