Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 57 of the 57 references it cites were found in a registry or an index; none of the 10 sources its claims cite is checked for support yet.

Real-time PCR assay is superior to other methods for the detection of mycoplasma contamination in the cell lines of the National Cell Bank of Iran

Open access

Abstract

Mycoplasmas are the most important contaminants of cell cultures throughout the world. They are considered as a major problem in biological studies and biopharmaceutical economic issues. In this study, our aim was to find the best standard technique as a rapid method with high sensitivity, specificity and accuracy for the detection of mycoplasma contamination in the cell lines of the National Cell Bank of Iran. Thirty cell lines suspected to mycoplasma contamination were evaluated by five different techniques including microbial culture, indirect DNA DAPI staining, enzymatic mycoalert(®) assay, conventional PCR and real-time PCR. Five mycoplasma-contaminated cell lines were assigned as positive controls and five mycoplasma-free cell lines as negative controls. The enzymatic method was performed using the mycoalert(®) mycoplasma detection kit. Real-time PCR technique was conducted by PromoKine diagnostic kits. In the conventional PCR method, mycoplasma genus-specific primers were designed to analyze the sequences based on a fixed and common region on 16S ribosomal RNA with PCR product size of 425 bp. Mycoplasma contamination was observed in 60, 56.66, 53.33, 46.66 and 33.33 % of 30 different cell cultures by real-time PCR, PCR, enzymatic mycoalert(®), indirect DNA DAPI staining and microbial culture methods, respectively. The analysis of the results of the different methods showed that the real-time PCR assay was superior the other methods with the sensitivity, specificity, accuracy, predictive value of positive and negative results of 100 %. These values were 94.44, 100, 96.77, 100 and 92.85 % for the conventional PCR method, respectively. Therefore, this study showed that real-time PCR and PCR assays based on the common sequences in the 16S ribosomal RNA are reliable methods with high sensitivity, specificity and accuracy for detection of mycoplasma contamination in cell cultures and other biological products.

Overview

CoChat Summary

TL;DR

In 30 cell lines from the National Cell Bank of Iran, real-time PCR detected mycoplasma contamination in 60% (18/30), more than conventional PCR, MycoAlert, DAPI staining, and microbial culture. Real-time PCR had 100% sensitivity, specificity, accuracy, and positive/negative predictive values, and was ranked best among the five methods.

Key findings

  • Contamination was detected in 60% (18/30) by real-time PCR, 56.66% (17/30) by conventional PCR, 53.33% (16/30) by enzymatic MycoAlert, 46.66% (14/30) by indirect DNA DAPI staining, and 33.33% (10/30) by microbial culture.
  • Real-time PCR showed sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of 100%. Conventional PCR showed sensitivity 94.44%, specificity 100%, accuracy 96.77%, positive predictive value 100%, and negative predictive value 92.85%. DAPI staining had specificity 84.21%, accuracy 75%, positive predictive value 82.35%, and negative predictive value 69.56%.
  • The real-time PCR kit detected as low as 15 fg of mycoplasma DNA, corresponding to approximately 10–15 mycoplasmas per sample volume. In serial dilutions, real-time PCR detected 10⁻⁴ (3 pg) of *M. hyorhinis* DNA, while conventional PCR detected 10⁻³ (30 pg).
  • Friedman ranking placed real-time PCR first (mean rank 2.63), followed by PCR (2.72), MycoAlert (2.80), microbial culture (3.30), and DAPI staining (3.55); the Friedman test P value was 0.000.

Methods

  • Thirty human and animal cell lines from the National Cell Bank of Iran were evaluated, with five positive and five negative control cell lines. Each sample was tested by microbial culture (used as gold standard), indirect DNA DAPI staining, enzymatic MycoAlert, conventional PCR, and real-time PCR.
  • Conventional PCR used universal primers targeting a conserved 16S rRNA region, producing a 425 bp product. Real-time PCR used the PromoKine PCR Mycoplasma Test Kit I/RT (Variant B), with target amplification monitored in FAM and internal inhibition control in VIC.
  • Statistical analysis used IBM SPSS version 22. Sensitivity, specificity, accuracy, and predictive values were calculated against microbial culture; t tests and Friedman tests were used, with P < 0.05 considered significant.

Limitations

  • The paper does not include a dedicated limitations section. It states method-specific limitations: microbial culture is slow and difficult to interpret; DAPI staining can be difficult to interpret due to contaminating bacteria or nucleic acid decomposition; MycoAlert can produce false negatives from impaired enzyme function and cannot discriminate ureaplasma/mycoplasma species; and it recommends using at least 2–3 methods in parallel.
  • Evident from the text: only 30 cell lines from one cell bank were tested, so findings may not generalize. Microbial culture was used as the gold standard despite 8 false negatives (26.66%) and a reported sensitivity of 55.55%, making the reference standard imperfect and the accuracy estimates potentially unstable.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1007/s10616-015-9862-0

Cites

57 of 57 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Verification

Claims the paper makes

0 Valid · 0 Not valid · 5 Not checked · 48 Own results and interpretations

27 more claims

Create a free account to see all 53 claims and every source verdict.

See all claims — free account
  • It may state two separate claims as one. 17
  • The quote only partly states this claim. 1
  • Probably not a substantial claim. 7

Create a free account to see these claims.

Citations

Cites

Show all 55 references

Cited by

See all 20

Metadata

Authors
Molla Kazemiha, V., Bonakdar, S., Amanzadeh, A., Azari, S., Memarnejadian, A., Shahbazi, S., Shokrgozar, M. A., & Mahdian, R.
Affiliations
  • Pasteur Institute of Iran (IR)
  • Tarbiat Modares University (IR)
Corresponding author
  • Shokrgozar, Mohammad Ali
  • Mahdian, Reza
Venue
Cytotechnology
Published
2015-03-06
Volume
68
Issue
4
Pages
1063-1080
ISSN
  • 0920-9069 (ISSN-L)
  • 1573-0778
OpenAlex
W2005195066
Cited by
20
References
55
Citations by year
2026: 1 · 2025: 2 · 2024: 1 · 2023: 1 · 2022: 1 · 2021: 3 · 2020: 4 · 2019: 5 · 2017: 1 · 2015: 1
FWCI
0.46
Type
journal article
Language
en
Open access
Licence
www.springer.com/tdm (tdm)
Locations
  • Cytotechnology (publishedVersion)
  • Europe PMC (PubMed Central) (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
Funders
Pasteur Institute of Iran
Topics
  • Life Sciences › Immunology and Microbiology › Microbiology › Microbial infections and disease research
  • Health Sciences › Medicine › Microbiology (medical) › Bacterial Identification and Susceptibility Testing
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Molecular Biology Techniques and Applications
Keywords
mycoplasma contamination, cell culture contamination, real-time PCR, 16S rRNA, conventional PCR, DAPI staining, microbial cultivation, sensitivity and specificity, cell lines

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

A language model drew the claims from the paper on 2026-10-07, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-07 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Real-time PCR assay is superior to other methods for the detection of mycoplasma contamination in the cell lines of the National Cell Bank of Iran. https://app.cochat.ai/papers/10.1007/s10616-015-9862-0
The paper
Molla Kazemiha, V., Bonakdar, S., Amanzadeh, A., Azari, S., Memarnejadian, A., Shahbazi, S., Shokrgozar, M. A., & Mahdian, R. (2016). Real-time PCR assay is superior to other methods for the detection of mycoplasma contamination in the cell lines of the National Cell Bank of Iran. Cytotechnology. https://doi.org/10.1007/s10616-015-9862-0

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.