The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Advances in Fecal Occult Blood Tests: The FIT Revolution
Open accessAbstract
UNLABELLED: There is a wide choice of fecal occult blood tests (FOBTs) for colorectal cancer screening. GOAL: To highlight the issues applicable when choosing a FOBT, in particular which FOBT is best suited to the range of screening scenarios. Four scenarios characterize the constraints and expectations of screening programs: (1) limited colonoscopy resource with a need to constrain test positivity rate; (2) a priority for maximum colorectal neoplasia detection with little need to constrain colonoscopy workload; (3) an "adequate" endoscopy resource that allows balancing the benefits of detection with the burden of service provision; and (4) a need to maximize participation in screening. Guaiac-based FOBTs (gFOBTs) have significant deficiencies, and fecal immunochemical tests (FITs) for hemoglobin have emerged as better tests. gFOBTs are not sensitive to small bleeds, specificity can be affected by diet or drugs, participant acceptance can be low, laboratory quality control opportunities are limited, and they have a fixed hemoglobin concentration cutoff determining positivity. FITs are analytically more specific, capable of quantitation and hence provide flexibility to adjust cutoff concentration for positivity and the balance between sensitivity and specificity. FITs are clinically more sensitive for cancers and advanced adenomas, and because they are easier to use, acceptance rates are high. CONCLUSIONS: FOBT must be chosen carefully to meet the needs of the applicable screening scenario. Quantitative FIT can be adjusted to suit Scenarios 1, 2 and 3, and for each, they are the test of choice. FITs are superior to gFOBT for Scenario 4 and gFOBT is only suitable for Scenario 1.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Diagnostic tests 4: likelihood ratios
Deeks, J. J., & Altman, D. G. (2004) · BMJ · doi:10.1136/bmj.329.7458.168 · Cited by 1,600
Long-term colorectal-cancer incidence and mortality after lower endoscopy
Nishihara, R., Wu, K., Lochhead, P., Morikawa, T., Liao, X., Qian, Z. R., Inamura, K., Kim, S. A., Kuchiba, A., Yamauchi, M., et al. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1301969 · Cited by 1,483
Cited by
Wolf, A. M. D., Fontham, E. T. H., Church, T. R., Flowers, C. R., Guerra, C. E., LaMonte, S. J., Etzioni, R., McKenna, M. T., Oeffinger, K. C., Shih, Y. T., et al. (2018) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.21457 · Cited by 1,944
Colorectal cancer development and advances in screening
Balchen, V., & Simon, K. (2016) · Clinical Interventions in Aging · doi:10.2147/cia.s109285 · Cited by 665
Colorectal cancer screening: An updated review of the available options
Issa, I. A., & Noureddine, M. (2017) · World Journal of Gastroenterology · doi:10.3748/wjg.v23.i28.5086 · Cited by 572
Colorectal Cancer: Epidemiology, Risk Factors, and Prevention
Roshandel, G., Ghasemi-Kebria, F., & Malekzadeh, R. (2024) · Cancers · doi:10.3390/cancers16081530 · Cited by 431
Atkin, W., Cross, A. J., Kralj-Hans, I., MacRae, E., Piggott, C., Pearson, S., Wooldrage, K., Brown, J., Lucas, F., Prendergast, A., et al. (2019) · Health Technology Assessment · doi:10.3310/hta23010 · Cited by 129
Self-citation
Metadata
- Authors
- Young, G. P., Symonds, E. L., Allison, J. E., Cole, S. R., Fraser, C. G., Halloran, S. P., Kuipers, E. J., & Seaman, H. E.
- Venue
- Digestive Diseases and Sciences
- Published
- 2014-12-10
- Volume
- 60
- Issue
- 3
- Pages
- 609-622
- ISSN
- 0163-2116 (ISSN-L)
- 1573-2568
- OpenAlex
- W2050899028
- Cited by
- 193
- References
- 2
- FWCI
- 6.18
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.