Design and Validation of a High-Temperature Comparative Thermal-Conductivity Measurement System
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Heat flow through MLI blankets can be calculated by using a calibrated rod provided that the cold boundary exchanges heat with the calibrated rod and 1st stage thermal shield only.
“As is shown in figure 1, heat flow through MLI blankets can be calculated by using a calibrated rod provided that the cold boundary exchange heat with calibrated rod and 1 st stage thermal shield only.”
From Design of a multi-layer insulation(MLI) measurement system with a G-M cryocooler (2019) · cites this paper as [9]
Cites
A frequency-domain thermoreflectance method for the characterization of thermal properties
Schmidt, A. J., Cheaito, R., & Chiesa, M. (2009) · Review of Scientific Instruments · doi:10.1063/1.3212673 · Cited by 543 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Xing, C., Folsom, C., Jensen, C., Ban, H., & Marshall, D. W. (2014) · Measurement Science and Technology · doi:10.1088/0957-0233/25/5/055602 · Cited by 9 · see citing works
Self-citationDesign of a multi-layer insulation(MLI) measurement system with a G-M cryocooler
Li, X., Xu, D., Shen, F., Liu, H., & Li, L. (2019) · IOP Conference Series: Materials Science and Engineering · doi:10.1088/1757-899x/502/1/012075 · Cited by 7 · see citing works
- Authors
- Jensen, C., Xing, C., Folsom, C., Ban, H., & Phillips, J.
- Affiliations
- Utah State University (US)
- Idaho National Laboratory (US)
- Corresponding author
- Jensen, C.
- Venue
- International Journal of Thermophysics
- Published
- 2012-01-31
- Volume
- 33
- Issue
- 2
- Pages
- 311-329
- ISSN
- 0195-928X (ISSN-L)
- 1572-9567
- OpenAlex
- W1995947142
- Cited by
- 31
- References
- 1
- Citations by year
- 2026: 1 · 2025: 1 · 2022: 1 · 2021: 1 · 2020: 1 · 2019: 3 · 2018: 1 · 2017: 3 · 2016: 5 · 2015: 1 · 2014: 9 · 2013: 3 · 2012: 1
- FWCI
- 2.06
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- International Journal of Thermophysics (publishedVersion)
- Digital Commons - USU (Utah State University) (submittedVersion)
- Funders
- U.S. Department of Energy
- Office of Nuclear Energy
- Idaho Operations Office, U.S. Department of Energy
- Nuclear Energy University Program
- Topics
- Physical Sciences › Materials Science › Materials Chemistry › Thermal properties of materials
- Physical Sciences › Materials Science › Materials Chemistry › Nuclear Materials and Properties
- Physical Sciences › Engineering › Computational Mechanics › Heat Transfer and Numerical Methods
- Keywords
- thermal conductivity measurement, high-temperature measurement, composite fuel, non-destructive measurement, measurement uncertainty evaluation, spent nuclear fuel, validation samples
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review