The DOI matches its Crossref record.
Vacuum Radiance-Temperature Standard Facility for Infrared Remote Sensing at NIM
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The reference radiation was directed into the spectrometer using an off-axis parabolic mirror in combination with a flat elliptical mirror, ensuring high-precision optical alignment and signal collection.
“And the reference radiation was directed into the spectrometer using an off-axis parabolic mirror in combination with a flat elliptical mirror, ensuring high-precision optical alignment and signal collection.”
From Thermal Radiation Testing Methods at Cryogenic Temperatures: A Review (2026) · cites this paper as [17]
The evolution of radiometric methods reveals a trend in cooling methods from reliance on external cryogenic liquids (such as liquid nitrogen and liquid helium) to integrated refrigeration systems.
“Initially, cooling methods evolved from reliance on external cryogenic liquids [17,44,49,55], such as liquid nitrogen and liquid helium, to integrated refrigeration system [37,54].”
From Thermal Radiation Testing Methods at Cryogenic Temperatures: A Review (2026) · cites this paper as [17]
The Hao et al. apparatus used a liquid-nitrogen cooled channel and Fourier-transform infrared spectrometry (FTIR) to measure emissivity above 190 K across the 1-1000 μm wavelength range.
“Liquid-nitrogen cooled channel and Fourier-transform infrared spectrometry (FTIR) were employed to measure emissivity above 190 K across the 1-1000 µm wavelength range.”
From Thermal Radiation Testing Methods at Cryogenic Temperatures: A Review (2026) · cites this paper as [17]
Hao et al. (2018) from the Chinese Academy of Metrology developed a vacuum radiation temperature standard apparatus for calibrating meteorological satellite infrared remote sensors.
“In 2018, Hao et al. [17] from the Chinese Academy of Metrology developed a vacuum radiation temperature standard apparatus for calibrating meteorological satellite infrared remote sensors.”
From Thermal Radiation Testing Methods at Cryogenic Temperatures: A Review (2026) · cites this paper as [17]
A liquid-nitrogen-cooled blackbody served as the FTIR radiation reference zero point in the Hao et al. system.
“A liquid-nitrogen-cooled blackbody served as the FTIR radiation reference zero point.”
From Thermal Radiation Testing Methods at Cryogenic Temperatures: A Review (2026) · cites this paper as [17]
Cryogenic optical sensors and space calibration systems require high-absorptivity blackbody coatings to ensure accurate signal detection and measurement.
“whereas cryogenic optical sensors and space calibration systems require high-absorptivity blackbody coatings to ensure accurate signal detection and measurement [17].”
From Thermal Radiation Testing Methods at Cryogenic Temperatures: A Review (2026) · cites this paper as [17]
There has been a transition in the arrangement of key optical paths from external detectors to fully integrated designs.
“Secondly, there has been a transition in the arrangement of key optical paths from external detectors [17,37,49,55] to fully integrated designs [54].”
From Thermal Radiation Testing Methods at Cryogenic Temperatures: A Review (2026) · cites this paper as [17]
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 16
- G. Ohring, B. Wielicki, R. Spencer, B. Emery, R. Datla, Bull. Am. Meteorol. Soc. 86, 9 (2005) · DOI
- J.B. Flowler, B.C. Johnson, J.P. Rice, S.R. Lorentz, Metrologia 35, 4 (1998)
- A.C. Carter, R.U. Datla, T.M. Jung, A.W. Smith, J.A. Fedchak, Metrologia 43, 2 (2006) · DOI
- J.P. Rice, B.C. Johnson, Metrologia 35, 4 (1998)
- S. Mekhontsev, L. Hanssen, S. Lorentz, J. Rice, in Proceedings of 11th International Conference on New Developments and Applications in Optical Radiometry, 2011
- C. Monte, B. Gutschwager, S.P. Morozova, J. Hollandt, Int. J. Thermophys. 30, 203 (2009) · DOI
- C. Monte, B. Gutschwager, A. Adibekyan, M. Kehrt, A. Ebersoldt, F. Olschewski, J. Holl. Atmos. Meas. Tech. Discuss. 6, 3 (2013)
- C. Monte, B. Gutschwager, A. Adibekyan, M. Kehrt, F. Olschewski, P. Preusse, J. Ungermann, H. Oelhaf, F. Friedl-Vallon, J. Hollandt, in Proceeding of 12th International Conference on New Developments and Applications in Optical Radiometry, Finland: NEWRAD, 2014
- V.S. Ivanov, B.E. Lisiansky, S.P. Morozova, V.I. Sapritsky, U.A. Melenevsky, L.Y. Xi, L. Pei, Metrologia 37, 5 (2002)
- S.P. Morozova, N.A. Parfentiev, B.E. Lisiansky, U.A. Melenevsky, B. Gutschwager, C. Monte, J. Hollandt, Int. J. Thermophys. 31, 8 (2010) · DOI
- S.P. Morozova, N.A. Parfentiev, B.E. Lisiansky, U.A. Melenevsky, B. Gutschwager, C. Monte, J. Hollandt, Int. J. Thermophys. 29, 1 (2008) · DOI
- V.I. Sapritsky, A.A. Katysheva, V.N. Krutikov, B.E. Lisyansky, S.P. Morozova, S.A. Ogarev, A.S. Panfilov, N.A. Parfentyev, D.M. Karpunin, E.V. Makolkin, in Proceeding of 12th International Conference on New Developments and Applications in Optical Radiometry, Finland: NEWRAD, 2014
- X.P. Hao, J. Song, J.P. Sun, M. Xu, Z.D. Yuan, Z.L. Liu, Opt. Precis. Eng. 23, 7 (2015)
- A. Adibekyan, E. Kononogova, C. Monte, J. Hollandt, Int. J. Thermophys. 38, 89 (2017) · DOI
- S.P. Sapritsky, A.V. Prohorov, Metrologica 29, 1 (1992) · DOI
- A. Adibekyan, C. Monte, M. Kehrt, B. Gutschwager, J. Hollandt, Int. J. Thermophys. 36, 283 (2015) · DOI · Paper page
Cited by
Sorted by citations
Thermal Radiation Testing Methods at Cryogenic Temperatures: A Review
Li, B., & Shen, F. (2026) · Cryo · doi:10.3390/cryo2010004 · Cited by 1
Metadata
- Authors
- Hao, X. P., Song, J., Xu, M., Sun, J. P., Gong, L. Y., Yuan, Z. D., & Lu, X. F.
- ORCID
- Hao, X. P.
- Venue
- International Journal of Thermophysics
- Published
- 2018-05-07
- Volume
- 39
- Issue
- 6
- ISSN
- 0195-928X
- 1572-9567
- Cited by
- 19
- References
- 0
- Language
- en
- Licence
- www.springer.com/tdm (tdm)
- Funders
- National Natural Science Foundation of China (11475162, 51576181)
- national high-tech R&D Program (2015AA123701)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review