Cited by 19

The DOI matches its Crossref record.

Vacuum Radiance-Temperature Standard Facility for Infrared Remote Sensing at NIM

Hao, X. P., Song, J., Xu, M., Sun, J. P., Gong, L. Y., Yuan, Z. D., Lu, X. F.·2018·International Journal of Thermophysics

Overview

Integrity signals

Registry

Crossref · 10.1007/s10765-018-2396-x

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The reference radiation was directed into the spectrometer using an off-axis parabolic mirror in combination with a flat elliptical mirror, ensuring high-precision optical alignment and signal collection.

    “And the reference radiation was directed into the spectrometer using an off-axis parabolic mirror in combination with a flat elliptical mirror, ensuring high-precision optical alignment and signal collection.”
  • The evolution of radiometric methods reveals a trend in cooling methods from reliance on external cryogenic liquids (such as liquid nitrogen and liquid helium) to integrated refrigeration systems.

    “Initially, cooling methods evolved from reliance on external cryogenic liquids [17,44,49,55], such as liquid nitrogen and liquid helium, to integrated refrigeration system [37,54].”
  • The Hao et al. apparatus used a liquid-nitrogen cooled channel and Fourier-transform infrared spectrometry (FTIR) to measure emissivity above 190 K across the 1-1000 μm wavelength range.

    “Liquid-nitrogen cooled channel and Fourier-transform infrared spectrometry (FTIR) were employed to measure emissivity above 190 K across the 1-1000 µm wavelength range.”
  • Hao et al. (2018) from the Chinese Academy of Metrology developed a vacuum radiation temperature standard apparatus for calibrating meteorological satellite infrared remote sensors.

    “In 2018, Hao et al. [17] from the Chinese Academy of Metrology developed a vacuum radiation temperature standard apparatus for calibrating meteorological satellite infrared remote sensors.”
  • A liquid-nitrogen-cooled blackbody served as the FTIR radiation reference zero point in the Hao et al. system.

    “A liquid-nitrogen-cooled blackbody served as the FTIR radiation reference zero point.”

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 16

  1. G. Ohring, B. Wielicki, R. Spencer, B. Emery, R. Datla, Bull. Am. Meteorol. Soc. 86, 9 (2005) · DOI
  2. J.B. Flowler, B.C. Johnson, J.P. Rice, S.R. Lorentz, Metrologia 35, 4 (1998)
  3. A.C. Carter, R.U. Datla, T.M. Jung, A.W. Smith, J.A. Fedchak, Metrologia 43, 2 (2006) · DOI
  4. J.P. Rice, B.C. Johnson, Metrologia 35, 4 (1998)
  5. S. Mekhontsev, L. Hanssen, S. Lorentz, J. Rice, in Proceedings of 11th International Conference on New Developments and Applications in Optical Radiometry, 2011
  6. C. Monte, B. Gutschwager, S.P. Morozova, J. Hollandt, Int. J. Thermophys. 30, 203 (2009) · DOI
  7. C. Monte, B. Gutschwager, A. Adibekyan, M. Kehrt, A. Ebersoldt, F. Olschewski, J. Holl. Atmos. Meas. Tech. Discuss. 6, 3 (2013)
  8. C. Monte, B. Gutschwager, A. Adibekyan, M. Kehrt, F. Olschewski, P. Preusse, J. Ungermann, H. Oelhaf, F. Friedl-Vallon, J. Hollandt, in Proceeding of 12th International Conference on New Developments and Applications in Optical Radiometry, Finland: NEWRAD, 2014
  9. V.S. Ivanov, B.E. Lisiansky, S.P. Morozova, V.I. Sapritsky, U.A. Melenevsky, L.Y. Xi, L. Pei, Metrologia 37, 5 (2002)
  10. S.P. Morozova, N.A. Parfentiev, B.E. Lisiansky, U.A. Melenevsky, B. Gutschwager, C. Monte, J. Hollandt, Int. J. Thermophys. 31, 8 (2010) · DOI
  11. S.P. Morozova, N.A. Parfentiev, B.E. Lisiansky, U.A. Melenevsky, B. Gutschwager, C. Monte, J. Hollandt, Int. J. Thermophys. 29, 1 (2008) · DOI
  12. V.I. Sapritsky, A.A. Katysheva, V.N. Krutikov, B.E. Lisyansky, S.P. Morozova, S.A. Ogarev, A.S. Panfilov, N.A. Parfentyev, D.M. Karpunin, E.V. Makolkin, in Proceeding of 12th International Conference on New Developments and Applications in Optical Radiometry, Finland: NEWRAD, 2014
  13. X.P. Hao, J. Song, J.P. Sun, M. Xu, Z.D. Yuan, Z.L. Liu, Opt. Precis. Eng. 23, 7 (2015)
  14. A. Adibekyan, E. Kononogova, C. Monte, J. Hollandt, Int. J. Thermophys. 38, 89 (2017) · DOI
  15. S.P. Sapritsky, A.V. Prohorov, Metrologica 29, 1 (1992) · DOI
  16. A. Adibekyan, C. Monte, M. Kehrt, B. Gutschwager, J. Hollandt, Int. J. Thermophys. 36, 283 (2015) · DOI · Paper page

Cited by

Sorted by citations

Metadata

Authors
Hao, X. P., Song, J., Xu, M., Sun, J. P., Gong, L. Y., Yuan, Z. D., & Lu, X. F.
Venue
International Journal of Thermophysics
Published
2018-05-07
Volume
39
Issue
6
ISSN
  • 0195-928X
  • 1572-9567
Cited by
19
References
0
Language
en
Funders
  • National Natural Science Foundation of China (11475162, 51576181)
  • national high-tech R&D Program (2015AA123701)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review