In vitro degradation behavior and cytocompatibility of Mg–Zn–Zr alloys
Open accessThe DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
Zinc and zirconium were selected as the alloying elements in biodegradable magnesium alloys, considering their strengthening effect and good biocompatibility. The degradation rate, hydrogen evolution, ion release, surface layer and in vitro cytotoxicity of two Mg-Zn-Zr alloys, i.e. ZK30 and ZK60, and a WE-type alloy (Mg-Y-RE-Zr) were investigated by means of long-term static immersion testing in Hank's solution, non-static immersion testing in Hank's solution and cell-material interaction analysis. It was found that, among these three magnesium alloys, ZK30 had the lowest degradation rate and the least hydrogen evolution. A magnesium calcium phosphate layer was formed on the surface of ZK30 sample during non-static immersion and its degradation caused minute changes in the ion concentrations and pH value of Hank's solution. In addition, the ZK30 alloy showed insignificant cytotoxicity against bone marrow stromal cells as compared with biocompatible hydroxyapatite (HA) and the WE-type alloy. After prolonged incubation for 7 days, a stimulatory effect on cell proliferation was observed. The results of the present study suggested that ZK30 could be a promising material for biodegradable orthopedic implants and worth further investigation to evaluate its in vitro and in vivo degradation behavior.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Magnesium and its alloys as orthopedic biomaterials: A review
Staiger, M. P., Pietak, A. M., Huadmai, J., & Dias, G. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.10.003 · Cited by 4,452
In vivo corrosion of four magnesium alloys and the associated bone response
Witte, F., Kaese, V., Haferkamp, H., Switzer, E., Meyer-Lindenberg, A., Wirth, C. J., & Windhagen, H. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.09.049 · Cited by 2,395 · cited 11×
“Mg OHð Þ2 sð Þ þ H2 gð Þ ð1Þ In a previous in vivo study, hydrogen evolving from WE43 during degradation was considered tolerable and could be dispersed by surrounding tissues [6].”
BackgroundResultInfluentialCorrosion Mechanisms of Magnesium Alloys
Song, G. L., & Atrens, A. (1999) · Advanced Engineering Materials · doi:10.1002/(sici)1527-2648(199909)1:1<11::aid-adem11>3.0.co;2-n · Cited by 2,365 · cited 3×
“Nevertheless, since the local concentration of Cl ions is one of the most important factors that determines the degradation rate of magnesium alloys when they are exposed to an aggressive electrolyte such as simulated body fluid or a NaCl solution [11], different behavior between different magnesium alloys in degradat…”
BackgroundInfluentialCalcium Phosphate Ceramics as Hard Tissue Prosthetics
JARCHO, M. (1981) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198106000-00037 · Cited by 2,014
Degradable biomaterials based on magnesium corrosion
Witte, F., Hort, N., Vogt, C., Cohen, S., Kainer, K. U., Willumeit, R., & Feyerabend, F. (2008) · Current Opinion in Solid State and Materials Science · doi:10.1016/j.cossms.2009.04.001 · Cited by 1,820 · cited 1×
“Most of the magnesium alloys that have so far been investigated as potential implant materials are rather complex in alloy composition and contain potentially toxic alloying elements [1, 4].”
BackgroundThe development of binary Mg–Ca alloys for use as biodegradable materials within bone
Li, Z., Gu, X., Lou, S., & Zheng, Y. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2007.12.021 · Cited by 1,593 · cited 1×
“In the present tests, after incubating at 37 C and in an atmosphere with 5% CO2 for one and 7 days [7, 27], 100 ll of the 0.”
MethodUse of an Aqueous Soluble Tetrazolium/Formazan Assay for Cell Growth Assays in Culture
Cory, A. H., Owen, T. C., Barltrop, J. A., & Cory, J. G. (1991) · Cancer Communications · doi:10.3727/095535491820873191 · Cited by 1,519 · cited 1×
“The number of viable cells was quantitatively assessed by the MTT test [26].”
MethodControl of biodegradation of biocompatable magnesium alloys
Song, G. (2007) · Corrosion Science · doi:10.1016/j.corsci.2007.01.001 · Cited by 1,514
In vitro corrosion and biocompatibility of binary magnesium alloys
Gu, X., Zheng, Y., Cheng, Y., Zhong, S., & Xi, T. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2008.10.021 · Cited by 1,343 · cited 4×
“WE43), controversy exists as to the biological effects of rare-earth elements in these alloys [6, 7].”
BackgroundMethodInfluentialResearch on an Mg–Zn alloy as a degradable biomaterial
Zhang, S., Zhang, X., Zhao, C., Li, J., Song, Y., Xie, C., Tao, H., Zhang, Y., He, Y., Jiang, Y., et al. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.06.028 · Cited by 1,336 · cited 2×
“implant and surrounding bone tissues due to rapid degradation, and (iv) good biocompatibility as evidenced by no negative effect of zinc release on the heart, kidney, liver and spleen [49].”
BackgroundResult
Cited by
Recent advances on the development of magnesium alloys for biodegradable implants
Chen, Y., Xu, Z., Smith, C., & Sankar, J. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.07.005 · Cited by 1,236
Park, J., Jiang, Q., Feng, D., Mao, L., & Zhou, H.-C. (2016) · Journal of the American Chemical Society · doi:10.1021/jacs.6b00007 · Cited by 915
Vojtěch, D., Kubásek, J., Šerák, J., & Novák, P. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.05.008 · Cited by 708
Kraus, T., Fischerauer, S. F., Hänzi, A. C., Uggowitzer, P. J., Löffler, J. F., & Weinberg, A. M. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.11.008 · Cited by 629
Ding, Y., Wen, C., Hodgson, P., & Li, Y. (2014) · J. Mater. Chem. B · doi:10.1039/c3tb21746a · Cited by 531
Mg and Mg alloys: How comparable are in vitro and in vivo corrosion rates? A review
Sanchez, A. H. M., Luthringer, B. J. C., Feyerabend, F., & Willumeit, R. (2015) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.11.048 · Cited by 503
Current status and outlook on the clinical translation of biodegradable metals
Han, H.-S., Loffredo, S., Jun, I., Edwards, J., Kim, Y.-C., Seok, H.-K., Witte, F., Mantovani, D., & Glyn-Jones, S. (2019) · Materials Today · doi:10.1016/j.mattod.2018.05.018 · Cited by 423
Magnesium biomaterials for orthopedic application: A review from a biological perspective
Walker, J., Shadanbaz, S., Woodfield, T. B. F., Staiger, M. P., & Dias, G. J. (2014) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.33113 · Cited by 352
Mechanical properties of magnesium alloys for medical application: A review
Chen, J., Tan, L., Yu, X., Etim, I. P., Ibrahim, M., & Yang, K. (2018) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2018.07.022 · Cited by 314
Biodegradable magnesium implants for orthopedic applications
Waizy, H., Seitz, J.-M., Reifenrath, J., Weizbauer, A., Bach, F.-W., Meyer-Lindenberg, A., Denkena, B., & Windhagen, H. (2013) · Journal of Materials Science · doi:10.1007/s10853-012-6572-2 · Cited by 297
Biodegradable Magnesium Alloys: A Review of Material Development and Applications
Persaud-Sharma, D., & McGoron, A. (2012) · Journal of Biomimetics, Biomaterials and Tissue Engineering · doi:10.4028/www.scientific.net/jbbte.12.25 · Cited by 287
Research on a Zn-Cu alloy as a biodegradable material for potential vascular stents application
Niu, J., Tang, Z., Huang, H., Pei, J., Zhang, H., Yuan, G., & Ding, W. (2016) · Materials Science and Engineering: C · doi:10.1016/j.msec.2016.06.082 · Cited by 280
Bairagi, D., & Mandal, S. (2022) · Journal of Magnesium and Alloys · doi:10.1016/j.jma.2021.09.005 · Cited by 272
Magnesium degradation under physiological conditions – Best practice
Gonzalez, J., Hou, R. Q., Nidadavolu, E. P. S., Willumeit-Römer, R., & Feyerabend, F. (2018) · Bioactive Materials · doi:10.1016/j.bioactmat.2018.01.003 · Cited by 262
In vivo degradation performance of micro-arc-oxidized magnesium implants: A micro-CT study in rats
Fischerauer, S. F., Kraus, T., Wu, X., Tangl, S., Sorantin, E., Hänzi, A. C., Löffler, J. F., Uggowitzer, P. J., & Weinberg, A. M. (2013) · Acta Biomaterialia · doi:10.1016/j.actbio.2012.09.017 · Cited by 229
“cellular blood composition [4–6].”
Surface modification of biodegradable magnesium and its alloys for biomedical applications
Tian, P., & Liu, X. (2015) · Regenerative Biomaterials · doi:10.1093/rb/rbu013 · Cited by 218
“Mg–Zn–Zr [58], Mg–Zn–Ag [59], Mg–Ca–Sr [60], Mg–Zn–Mn [61] and Mg–Nb–Zn–Zr [62, 63], etc.”
Magnesium-based biodegradable alloys: Degradation, application, and alloying elements
Pogorielov, M., Husak, E., Solodivnik, A., & Zhdanov, S. (2017) · Interventional Medicine and Applied Science · doi:10.1556/1646.9.2017.1.04 · Cited by 150
“%) were further alloyed by adding the third alloying elements, including Ca [96], Mn [97], Sr, Y, and Zr [98].”
Background
Metadata
- Authors
- Huan, Z. G., Leeflang, M. A., Zhou, J., Fratila-Apachitei, L. E., & Duszczyk, J.
- Venue
- Journal of Materials Science: Materials in Medicine
- Published
- 2010-06-09
- Volume
- 21
- Issue
- 9
- Pages
- 2623-2635
- ISSN
- 0957-4530 (ISSN-L)
- 1573-4838
- OpenAlex
- W1983702781
- Cited by
- 234
- References
- 34
- FWCI
- 4.88
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.