Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.

Effects of fatigue induced damage on the longitudinal fracture resistance of cortical bone

Fletcher, Lloyd, Codrington, John, Parkinson, Ian · 2014 · Journal of Materials Science: Materials in Medicine

Abstract

As a composite material, cortical bone accumulates fatigue microdamage through the repetitive loading of everyday activity (e.g. walking). The accumulation of fatigue microdamage is thought to contribute to the occurrence of fragility fractures in older people. Therefore it is beneficial to understand the relationship between microcrack accumulation and the fracture resistance of cortical bone. Twenty longitudinally orientated compact tension fracture specimens were machined from a single bovine femur, ten specimens were assigned to both the control and fatigue damaged groups. The damaged group underwent a fatigue loading protocol to induce microdamage which was assessed via fluorescent microscopy. Following fatigue loading, non-linear fracture resistance tests were undertaken on both the control and damaged groups using the J-integral method. The interaction of the crack path with the fatigue induced damage and inherent toughening mechanisms were then observed using fluorescent microscopy. The results of this study show that fatigue induced damage reduces the initiation toughness of cortical bone and the growth toughness within the damage zone by three distinct mechanisms of fatigue-fracture interaction. Further analysis of the J-integral fracture resistance showed both the elastic and plastic component were reduced in the damaged group. For the elastic component this was attributed to a decreased number of ligament bridges in the crack wake while for the plastic component this was attributed to the presence of pre-existing fatigue microcracks preventing energy absorption by the formation of new microcracks.

Overview

Integrity signals

Registry

Crossref · 10.1007/s10856-014-5213-5

Cites

41 of 41 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 41 references

Cited by

See all 12

Metadata

Authors
Fletcher, L., Codrington, J., & Parkinson, I.
Affiliations
  • The University of Adelaide (AU)
  • South Australia Pathology (AU)
Corresponding author
Fletcher, Lloyd
Venue
Journal of Materials Science: Materials in Medicine
Published
2014-04-09
Volume
25
Issue
7
Pages
1661-1670
ISSN
  • 0957-4530 (ISSN-L)
  • 1573-4838
OpenAlex
W2049227705
Cited by
12
References
41
Citations by year
2024: 1 · 2022: 1 · 2021: 1 · 2020: 2 · 2018: 1 · 2015: 5 · 2014: 1
FWCI
2.07
Type
journal article
Language
en
Open access
closed
Licence
www.springer.com/tdm (tdm)
Locations
  • Journal of Materials Science Materials in Medicine (publishedVersion)
  • PubMed (publishedVersion)
  • Adelaide Research & Scholarship (AR&S) (University of Adelaide) (submittedVersion)
Topics
  • Physical Sciences › Engineering › Mechanics of Materials › Fatigue and fracture mechanics
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
Keywords
cortical bone, fatigue damage, fatigue microcracks, fracture resistance, compact tension specimens, J-integral, initiation toughness, crack wake, bovine femur, fragility fractures, energy absorption
MeSH terms
Animals, Biomechanical Phenomena, Bone and Bones, Cattle, Femur, Microscopy, Fluorescence, Stress, Mechanical, Fractures, Stress, Fractures, Bone

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effects of fatigue induced damage on the longitudinal fracture resistance of cortical bone. https://app.cochat.ai/papers/10.1007/s10856-014-5213-5
The paper
Fletcher, L., Codrington, J., & Parkinson, I. (2014). Effects of fatigue induced damage on the longitudinal fracture resistance of cortical bone. Journal of Materials Science: Materials in Medicine. https://doi.org/10.1007/s10856-014-5213-5

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.