Artifacts can emerge in spectra recorded with even the simplest of pulse schemes: an HMQC case study
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
With the development of sophisticated pulsed field gradient- and phase cycling-approaches for suppressing certain coherence transfer pathways and selecting for others it is sometimes easy to forget that the process is not flawless. In some cases artifacts can emerge because unwanted transfers are immune to the phase cycle or the application of gradients. We consider here a simple 1 H, 13 C HMQC pulse scheme and show that imperfections in the single 1 H 180° refocusing pulse can give rise to small artifacts in methyl spectra that cannot be eliminated through extensive phase cycling or the use of gradients, but that are easily removed when the pulse is of the composite variety.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Fourth, field inhomogeneity and pulse imperfections can significantly impact the sensitivity of the experiments even for simple spin operations27,28.”
From AI-designed NMR spectroscopy RF pulses for fast acquisition at high and ultra-high magnetic fields (2023) · cites this paper as [27]
Citations
Cites
Tugarinov, V., Hwang, P. M., Ollerenshaw, J. E., & Kay, L. E. (2003) · Journal of the American Chemical Society · doi:10.1021/ja030153x · Cited by 649
Self-citationDynamic Regulation of Archaeal Proteasome Gate Opening As Studied by TROSY NMR
Religa, T. L., Sprangers, R., & Kay, L. E. (2010) · Science · doi:10.1126/science.1184991 · Cited by 240
Self-citation
Research works printed but not linked: 19
- Bax A (1985) A spatially selective composite 90o radiofrequency pulse. J Mag Reson 65:142–145
- Bax A (1994) Multidimensional nuclear magnetic resonance methods for protein studies. Curr Opin Struct Biol 4:738–744 · DOI
- Bax A, Griffey RH, Hawkings BL (1983) Correlation of proton and nitrogen-15 chemical shifts by multiple quantum. NMR J Magn Reson 55:301–315
- Bax A, Clore GM, Driscoll PC, Gronenborn AM, Ikura M, Kay LE (1990) Practical aspects of proton-carbon-carbon-proton three-dimensional correlation spectroscopy of 13C-labeled proteins. J Magn Reson 87:620–627
- Bodenhausen G, Freeman R, Turner DL (1977) Suppression of artifacts in two-dimensional J spectroscopy. J Magn Reson 27:511–514
- Cavanagh J, Fairbrother WJ, Palmer AG, Skelton NJ (1996) Protein nmr spectroscopy: principles and practice. Academic Press, San Diego
- Ernst RR, Bodenhausen G, Wokaun A (1987) Principles of nuclear magnetic resonance in one and two dimensions. Oxford University Press, Oxford
- Freeman R, Keller J (1981) Suppression of artifacts in two-dimensional J Spectra. J Magn Reson 43:484–487
- Freeman R, Kempsell SP, Levitt MH (1980) Radiofrequency pulse sequences which compensate their own imperfections. J Magn Reson 38:453–479
- Huang R, Perez F, Kay LE (2017) Probing the cooperativity of Thermoplasma acidophilum proteasome core particle gating by NMR spectroscopy. Proc Natl Acad Sci USA 114:E9846–E9854. https://doi.org/10.1073/pnas.1712297114 · DOI
- Kay LE, Bax A (1990) New methods for the measurement of NH-CaH coupling constants in 15N-labeled proteins. J Magn Reson 86:110–126
- Kay LE, Prestegard JH (1987) Methyl group dynamics from relaxation of double quantum filtered NMR signals-application to deoxycholate. J Am Chem Soc 109:3829–3835 · DOI
- Kay LE, Torchia DA, Bax A (1989) Backbone dynamics of proteins as studied by 15N inverse detected heteronuclear NMR spectroscopy: application to staphylococcal nuclease. Biochemistry 28:8972–8979 · DOI · Paper page
- Kay LE, Bull TE, Nicholson LK, Griesinger C, Schwalbe H, Bax A, Torchia DA (1992) The measurement of heteronuclear transverse relaxation times in AX3 spin systems via polarization transfer techniques. J Magn Reson 100:538–558
- Levitt M, Freeman R (1978) NMR population inversion using a composite pulse. J Magn Reson 33:473–476
- Montelione GT, Wagner G (1990) Conformation-independent sequential NMR connections in isotope-enriched peptides by H-1C-13-N15 triple resonance experiments. J Magn Reson 87:183–188
- Mueller L (1979) Sensitivity enhanced detection of weak nuclei using heteronuclear multiple quantum coherence. J Am Chem Soc 101:4481–4484 · DOI
- Rosenzweig R, Kay LE (2014) Bringing dynamic molecular machines into focus by methyl-TROSY NMR. Annu Rev Biochem 83:291–315 · DOI · Paper page
- Sattler M, Schleucher J, Griesinger C (1999) Heteronuclear multidimensional NMR experiments for the structure determination of proteins in solution employing pulsed field gradients. Prog Nucl Magn Reson Spectrosc 34:93–158 · DOI · Paper page
Cited by
AI-designed NMR spectroscopy RF pulses for fast acquisition at high and ultra-high magnetic fields
Manu, V. S., Olivieri, C., & Veglia, G. (2023) · Nature Communications · doi:10.1038/s41467-023-39581-4 · Cited by 35
Manu, V. S., Pavuluri, K., Mullen, M., Garwood, M., & Veglia, G. (2021) · doi:10.21203/rs.3.rs-403351/v1 · Cited by 24
Metadata
- Authors
- Kay, L. E.
- Venue
- Journal of Biomolecular NMR
- Published
- 2019-02-23
- Volume
- 73
- Issue
- 8-9
- Pages
- 423-427
- ISSN
- 0925-2738
- 1573-5001
- Cited by
- 12
- References
- 2
- Language
- en
- Licence
- www.springer.com/tdm (tdm)
- Funders
- CIHR (1234)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.