Hybridization of TEDOR and NCX MAS solid-state NMR experiments for simultaneous acquisition of heteronuclear correlation spectra and distance measurements
Open accessThe DOI matches its Crossref record; 66 of the 66 references it cites were found in a registry or an index; 7 of the 62 sources its claims cite were checked for support.
Abstract
Magic angle spinning (MAS) solid-state NMR (ssNMR) spectroscopy is a major technique for the characterization of the structural dynamics of biopolymers at atomic resolution. However, the intrinsic low sensitivity of this technique poses significant limitations to its routine application in structural biology. Here we achieve substantial savings in experimental time using a new subclass of Polarization Optimized Experiments (POEs) that concatenate TEDOR and SPECIFIC-CP transfers into a single pulse sequence. Specifically, we designed new 2D and 3D experiments (2D TEDOR-NCX, 3D TEDOR-NCOCX, and 3D TEDOR-NCACX) to obtain distance measurements and heteronuclear chemical shift correlations for resonance assignments using only one experiment. We successfully tested these experiments on N-Acetyl-Val-Leu dipeptide, microcrystalline U-13C,15N ubiquitin, and single- and multi-span membrane proteins reconstituted in lipid membranes. These pulse sequences can be implemented on any ssNMR spectrometer equipped with standard solid-state hardware using only one receiver. Since these new POEs speed up data acquisition considerably, we anticipate their broad application to fibrillar, microcrystalline, and membrane-bound proteins.
Overview
CoChat Summary
TL;DR
The paper introduces hybrid TEDOR-NCX MAS solid-state NMR pulse sequences that concatenate TEDOR and SPECIFIC-CP transfers to acquire heteronuclear correlation spectra and distance measurements simultaneously in one experiment. It demonstrates 2D and 3D variants on NAVL dipeptide, microcrystalline ubiquitin, and the membrane proteins sarcolipin (SLN) and SatP, reporting substantial time savings and signal gains.
Key findings
- New 2D TEDOR-NCX, 3D TEDOR-NCOCX, and 3D TEDOR-NCACX experiments combine TEDOR distance measurements with NCX chemical-shift correlations in a single pulse sequence, implementable on standard ssNMR hardware with one receiver.
- For U-13C,15N SLN, 2D TEDOR-NCA acquisition took 27.8 h; adding the second acquisition increased time by only 16 min, whereas conventional 2D TEDOR alone would have taken 27.5 h. Summing TEDOR and NCA gave an average net signal-intensity increase of 32%; normalized 1D 13Cα intensities were 1.00 (TEDOR) and 0.99 (TEDOR-NCA), 13CO were 1.00 and 0.94, and second-acquisition NCA 13Cα was 0.95; adding the spectra increased S/N by 38%.
- For U-13C,15N SatP, 1D NCA intensities were about 10–30% higher than TEDOR, 2D NCA was ~30% higher than TEDOR, and the sum of TEDOR and NCA gave a 60% signal gain over TEDOR alone. For U-13C,15N ubiquitin, integrated 2D NCA and NCO intensities were 1.2 and 0.7 times the TEDOR intensity.
- 3D TEDOR on NAVL yielded distances of 2.7 Å for Val N–Val Cβ and 3.5 Å for Leu N–Val Cβ, close to literature values. NCACX DARR cross-peaks showed Val Cα–Cβ highest at 50 ms, while inter-residue Val Cα–Leu Cα required 150 ms to build up. TEDOR detected Pro residues more efficiently than NCA because of inefficient 15N CP from the absence of directly bound protons to Pro imino groups.
Methods
- Design: hybrid polarization optimized experiments (POEs) concatenating TEDOR and SPECIFIC-CP transfers; coherence transfer pathways described with product operator formalism; 2D TEDOR-NCX, 3D TEDOR-NCOCX, 3D TEDOR-NCACX, and pseudo-3D TEDOR-NCACX-NCOCX sequences.
- Samples and instrumentation: U-13C,15N NAVL dipeptide, microcrystalline ubiquitin, SLN reconstituted into DMPC at lipid-to-protein ratio 100 (0.6 mg SLN/12 mg DMPC), and SatP reconstituted into DMPC at ratio 40 (8 mg SatP/12 mg DMPC). Experiments used Agilent and Bruker spectrometers at 600 MHz 1H Larmor frequency, MAS 12.5 kHz, 3.2 mm scroll coil for SLN/ubiquitin/NAVL and 1.3 mm Bruker probe for SatP, 3 s recycle delay, 500 μs CP/SIM-CP, TEDOR tmix 1.28 ms for 1D/2D and arrayed 1.28–17.92 ms for 3D, with SPINAL-64 1H decoupling.
- Analysis: integrated intensities normalized to TEDOR spectra to quantify signal gains; TEDOR peak intensities fit to simulated curves using equations from reference 19; DARR intensities normalized to the Val Cα NCA peak; temperature series acquired above and below the DMPC phase transition.
Limitations
- Stated: longer SPECIFIC-CP transfer periods (3–6 ms) may cause inefficient polarization transfer due to fast T1ρ relaxation and/or RF inhomogeneity; TEDOR relies on 180° pulse efficiency and T2 relaxation of antiphase spin operators, which is relatively short for biomolecular solids. Performance may depend mostly on sample heterogeneity and protein dynamics, with NCA more efficient than TEDOR for SatP. Multiple acquisitions may increase RF duty cycles, though the sequences remained within power limits for commercial E-free or low-E MAS probes.
- Stated: the NAVL crystal contained 100% U-13C,15N labeled molecules, which may cause slight deviations from theoretical TEDOR curves due to inter-molecular dipolar couplings. DARR peak intensities are less quantitative than TEDOR, so the authors advise acquiring multiple DARR spectra at different mixing times and classifying distances up to 10 Å. In the 3D experiment, initial polarization of NCACX and NCOCX can differ slightly due to 180° pulses on 15N z-magnetization during TEDOR mixing, with less than 10% intensity loss even at longer mixing times.
- Evident from the text: demonstrations are limited to NAVL, ubiquitin, SLN, and SatP, and no new high-resolution structures are reported; the authors present these experiments as complementary to, not replacements for, existing sensitivity-enhancement methods.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
1 Valid · 1 Not valid · 23 Not checked · 48 Own results and interpretations
None of the sources cited for this claim have been checked yet.
In the paper
“As shown previously, 30–35% of signal intensity is retained by the residual 15N polarization after the NCA transfer 8,37”
§ Hybridization of TEDOR and NCX MAS solid-state NMR experiments for simultaneous acquisition of heteronuclear correlation spectra and distance measurements > RESULTS > Simultaneous acquisition of TEDOR, NCA, and NCO correlation experiments.
What the sources say
- Not checked yetcites [8] Buck B Overexpression, purification, and characterization of recombinant Ca-ATPase regulators for high-resolution solution and solid-state NMR studies. Protein Expression and Purification 30, 253– 261 (2003). 12880775 source
- Could not verifycites [37] Manu VS & Veglia G Optimization of identity operation in NMR spectroscopy via genetic algorithm: Application to the TEDOR experiment. J Magn Reson 273, 40– 46 (2016). 27744147 PMC5423402 sourceExperimental — accuracy not yet measured
Our copy of Manu & Veglia (2016) covers GA-optimized identity/π-pulse phase modulations for the 13C–15N GMO-TEDOR recoupling, reporting sensitivity enhancements over XY8 (10.2–15.9% offset-averaged, up to 27.7–28.4% maximum; Results and discussion) and general 'severe loss of signal during the REDOR recoupling' — but it never mentions an NCA transfer step or a residual 15N polarization retaining 30–35% of signal intensity. Its TEDOR experiment starts with a 1H→13C CP transfer (Results and discussion), not a preceding NCA transfer, so the specific quantity the claim attributes to this source is absent. Searched: 'residual 15N polarization after NCA transfer', 'NCA amide carbon nitrogen transfer prior to TEDOR', 'percentage of signal lost / 30% 35%' — no passage addresses the claim's point, and none contradicts it. (LLM, conf=0.68)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
The cited sources that could be checked couldn’t confirm or dispute this claim.
In the paper
“Note that in equation 1, the spin coherences such as [Cx·cos(ω·tmix/2)], [2CyNz·sin (ω·tmix/2) ·cos(ω·tmix/2)], and other multiple quantum terms (not shown) created by homonuclear 13C-13C J-couplings are eliminated by 15N phase cycling (ϕ2) and Δ periods as shown in Figures 1A and 1B 19.”
§ Hybridization of TEDOR and NCX MAS solid-state NMR experiments for simultaneous acquisition of heteronuclear correlation spectra and distance measurements > RESULTS > Simultaneous acquisition of TEDOR and NCX experiments.
What the sources say
- Could not verifycites [19] Gopinath T & Veglia G Orphan spin operators enable the acquisition of multiple 2D and 3D magic angle spinning solid-state NMR spectra. J Chem Phys 138, 184201 (2013). 23676036 PMC3663853 sourceExperimental — accuracy not yet measured
Our copy's THEORY section models only a two-spin 15N-13Cα system under the recoupled dipolar Hamiltonian (Eqs. 1-12, 'Encoding four independent polarization pathways'); its Eq. (1) is ρ(t1=0) ∝ a_Cα·Cαx + b_N·Nx and contains no 13C-13C J-coupling terms, no tmix-dependent terms such as [Cx·cos(ω·tmix/2)] or [2CyNz·sin(ω·tmix/2)·cos(ω·tmix/2)], and no Δ periods. The paper does define a 15N phase cycle φ2 = (x, x, -x, -x)2 (Fig. 1 caption / Methods), but there it is used to encode the four pathways with +x/-x 15N spin-lock phases for Hadamard decoding, not to cancel homonuclear J coherences; the only multi-spin attenuation factors named are the 13C and 15N homo- and hetero-nuclear dipolar coupling network, 1H decoupling, T1ρ and RF inhomogeneity (same section). Searches for 'homonuclear 13C-13C J coupling', 'scalar coupling', 'multiple quantum terms eliminated', 'delta periods' and 'phase cycling φ2' returned no passage addressing the claim, so our copy neither supports nor contradicts it. (LLM, conf=0.68)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Could not verify
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Here, we expanded the POE toolkit 18 by hybridizing transferred echo double resonance (TEDOR) 19–22 and spectrally induced filtering in combination with cross-polarization (SPECIFIC-CP) 23 transfer elements to record 13C-15N correlation experiments in the first and subsequence multiple acquisitions.”
§ Hybridization of TEDOR and NCX MAS solid-state NMR experiments for simultaneous acquisition of heteronuclear correlation spectra and distance measurements > INTRODUCTION
What the sources say
- Partly supportedcites [18] Gopinath T & Veglia G 3D DUMAS: simultaneous acquisition of three-dimensional magic angle spinning solid-state NMR experiments of proteins. J Magn Reson 220, 79– 84 (2012). 22698806 PMC3487463 sourceExperimental — accuracy not yet measured
Our copy supports the SPECIFIC-CP half of the claim and the 'first and subsequent multiple acquisitions' part: the INTRODUCTION states the SIM-CP block creates initial polarization for 13C and 15N 'combined with specific-CP between 15N and 13C to generate two independent pathways ... resulting in two separate 3D experiments', and the RESULTS ('3D DUMAS experiments', Figure 1C) describe the first acquisition (NCACX) followed by the second acquisition (CANCO) of 13C-15N correlations. However, no passage in our copy mentions TEDOR (searched: TEDOR, transferred echo double resonance); the element hybridized with specific-CP in this paper is simultaneous cross-polarization (SIM-CP) from 1H to 13C/15N, plus DARR mixing. The TEDOR attribution is therefore not supported by this source. (LLM, conf=0.78)
- Partly supportedcites [19] Gopinath T & Veglia G Orphan spin operators enable the acquisition of multiple 2D and 3D magic angle spinning solid-state NMR spectra. J Chem Phys 138, 184201 (2013). 23676036 PMC3663853 sourceExperimental — accuracy not yet measured
Our copy supports most of the sentence: the 'CO magnetization of NCO/CON is about 40%' section states 'The MEIOSIS method was developed using the POE philosophy,' and the THEORY / 'Encoding four independent polarization pathways' sections describe a specific-CP 15N-13C element whose four pathways are read out in a 1st and 2nd acquisition (Eq. 9-10), i.e. an expanded POE toolkit recording 13C-15N correlations in successive acquisitions. However, no passage in our copy mentions TEDOR or any dipolar-recoupling-based heteronuclear transfer being hybridized with specific-CP; the implemented hybrid is SIM-CP + bidirectional specific-CP + DARR homonuclear spin exchange (MATERIALS AND METHODS; INTRODUCTION), and other 15N-13C transfer schemes (symmetry-based, PAIN-CP, optimal-control) are only anticipated as future extensions, not demonstrated. The TEDOR half of the attribution is therefore not supported by this source. (LLM, conf=0.78)
- Partly supportedcites [20] Gopinath T & Veglia G Multiple acquisition of magic angle spinning solid-state NMR experiments using one receiver: application to microcrystalline and membrane protein preparations. J Magn Reson 253, 143– 53 (2015). 25797011 PMC4399235 sourceExperimental — accuracy not yet measured
Our copy supports the SPECIFIC-CP half of the attribution: Section 3 ('Bidirectional Specific-CP and Residual Polarization') describes SIM-CP followed by bidirectional specific-CP giving NCA/CAN (and NCO/CON) 13C-15N transfers, with the CA polarization detected in the first acquisition and the stored 15N polarization transferred for a second acquisition, and Sections 6-8 extend this to multiple (up to four) simultaneous acquisitions. However, no passage of our copy mentions TEDOR or any transferred-echo/double-resonance element being hybridized with SPECIFIC-CP; the paper's own expansion of the POE family (Discussion, Sec. 10) credits 1H-detected fast-MAS experiments, Traaseth's afterglow, Meier's PAIN/PAR and dipolar-edited DUMAS variants, not TEDOR. The TEDOR component of the claim is therefore not supported by this source. (LLM, conf=0.72)
- Partly supportedcites [21] Gopinath T & Veglia G Multiple acquisitions via sequential transfer of orphan spin polarization (MAeSTOSO): How far can we push residual spin polarization in solid-state NMR? J Magn Reson 267, 1– 8 (2016). 27039168 PMC4862926 sourceExperimental — accuracy not yet measured
Our copy supports most of the attribution: the Conclusions state 'we added a new strategy (MAeSTOSO) to the class of POE', and the Results (Multidimensional CC and NC correlation experiments using MAeSTOSO-4) describe recording a 2D CC experiment in the first acquisition and 15N-edited NC experiments in the subsequent three, with the heteronuclear 13C-15N transfer 'obtained using the specific-CP sequence' (also Material and Methods, NCA/NCO specific-CP settings). However, no passage of our copy mentions TEDOR (searched: TEDOR, transferred echo double resonance, echo double resonance); the hybridized elements are SIM-CP plus bidirectional specific-CP, with DARR/DREAM for homonuclear 13C-13C mixing. The 'TEDOR' component of the claim is therefore not supported by this source. (LLM, conf=0.72)
- Partly supportedcites [22] Gopinath T & Veglia G Orphan Spin Polarization: A Catalyst for High-Throughput Solid-State NMR Spectroscopy of Proteins. Annual Reports on NMR Spectroscopy 89, 103– 21 (2016). PMC6800253 31631914 sourceExperimental — accuracy not yet measured
Our copy confirms the POE framework and its Specific-CP-based multi-acquisition expansion: the MEIOSIS section states that 'the combination of SIM-CP and Specific-CP creates four polarization pathways that can be used for recording four different experiments utilizing two acquisitions per scan', with 13C-15N (NCA/CAN) pathways decoded in the first and second acquisitions (Deconvolution section, Fig. 6A–D), and MAeSTOSO extending this to four acquisitions ('How far can we push the residual polarization?'). However, no passage of our copy mentions TEDOR or a TEDOR/SPECIFIC-CP hybrid — the transfer element the chapter attributes to the 13C-15N steps is Specific-CP combined with SIM-CP — so that part of the claim is not supported by this source. (LLM, conf=0.75)
- Not checked yetcites [23] Gopinath T & Veglia G Experimental Aspects of Polarization Optimized Experiments (POE) for Magic Angle Spinning Solid-State NMR of Microcrystalline and Membrane-Bound Proteins. Methods Mol Biol 1688, 37– 53 (2018). 29151203 source
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Rests on 2 assumptions not shown here.
- Partly supported
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“After summing the TEDOR and NCA data sets, we obtained an average net increase in signal intensity of 32% (Figure 3C).”
§ Hybridization of TEDOR and NCX MAS solid-state NMR experiments for simultaneous acquisition of heteronuclear correlation spectra and distance measurements > RESULTS > Simultaneous acquisition of TEDOR and NCX experiments.
plainstates a causeSingle case- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim have been checked yet.
In the paper
“The peak positions of U-13C,15N SLN match our previous resonance assignments obtained with the 3D-DUMAS-NCACX-CANCO experiment 10,36.”
§ Hybridization of TEDOR and NCX MAS solid-state NMR experiments for simultaneous acquisition of heteronuclear correlation spectra and distance measurements > RESULTS > Simultaneous acquisition of TEDOR and NCX experiments.
What the sources say
- Not checked yetcites [10] Das BB & Opella SJ Simultaneous cross polarization to (13)C and (15)N with (1)H detection at 60kHz MAS solid-state NMR. J Magn Reson 262, 20– 26 (2016). 26705905 PMC4716881 source
- Not checked yetcites [36] Jaroniec CP, Filip C & Griffin RG 3D TEDOR NMR experiments for the simultaneous measurement of multiple carbon-nitrogen distances in uniformly (13)C,(15)N-labeled solids. J Am Chem Soc 124, 10728– 42 (2002). 12207528 source
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
35 more claims
Create a free account to see all 73 claims and to verify the 55 references still open.
- It may state two separate claims as one. 16
- Probably not a substantial claim. 21
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“All of these pulse sequences were tested with both crystalline preparations of globular proteins and single and/or multi-span membrane proteins such as sarcolipin (SLN), phospholamban (PLN), and SatP.52”
From Solid-State NMR of Membrane Proteins in Lipid Bilayers: To Spin or Not To Spin? (2021) · cites this paper as [52]
In the citing paper
“POE can also take advantage of the afterglow phenomenon, introduced by Traaseth and co-workers,53 which can be incorporated into Transferred Echo DOuble Resonance (TEDOR)-NCX-based pulse sequences.52”
From Solid-State NMR of Membrane Proteins in Lipid Bilayers: To Spin or Not To Spin? (2021) · cites this paper as [52]
In the citing paper
“Along with auxiliary developments made by other research groups, the POE family now includes 1H-detected experiments under fast MAS conditions, afterglow, dipolar-edited versions of DUMAS pulse sequences, and, more recently, hybrid pulse sequences combining CP and INEPT transfer periods27–34.”
From Multi-receiver solid-state NMR using polarization optimized experiments (POE) at ultrafast magic angle spinning (2020) · cites this paper as [34]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Hybridization of TEDOR and NCX MAS solid-state NMR experiments for simultaneous acquisition of heteronuclear correlation spectra and distance measurements > RESULTS > Simultaneous acquisition of TEDOR, NCA, and NCO correlation experiments.
“30–35% of signal intensity is retained by the residual 15N polarization after the NCA transfer”
§ Hybridization of TEDOR and NCX MAS solid-state NMR experiments for simultaneous acquisition of heteronuclear correlation spectra and distance measurements > RESULTS > Simultaneous acquisition of TEDOR, NCA, and NCO correlation experiments.
“hence the third spectrum is typically 30–35 % less intense than the second spectrum.”
Citations
Cites
Nuclear Double Resonance in the Rotating Frame
Hartmann, S. R., & Hahn, E. L. (1962) · Physical Review · doi:10.1103/physrev.128.2042 · Cited by 2,236
An Improved Broadband Decoupling Sequence for Liquid Crystals and Solids
Fung, B. M., Khitrin, A. K., & Ermolaev, K. (2000) · Journal of Magnetic Resonance · doi:10.1006/jmre.1999.1896 · Cited by 1,987
– dipolar-assisted rotational resonance in magic-angle spinning NMR
Takegoshi, K., Nakamura, S., & Terao, T. (2001) · Chemical Physics Letters · doi:10.1016/s0009-2614(01)00791-6 · Cited by 1,012
Pines, A., Gibby, M. G., & Waugh, J. S. (1972) · The Journal of Chemical Physics · doi:10.1063/1.1677439 · Cited by 952
Structure of a protein determined by solid-state magic-angle-spinning NMR spectroscopy
Castellani, F., van Rossum, B., Diehl, A., Schubert, M., Rehbein, K., & Oschkinat, H. (2002) · Nature · doi:10.1038/nature01070 · Cited by 910
New, compensated Carr-Purcell sequences
Gullion, T., Baker, D. B., & Conradi, M. S. (1990) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(90)90331-3 · Cited by 724
BALDUS, M., PETKOVA, A. T., HERZFELD, J., & GRIFFIN, R. G. (1998) · Molecular Physics · doi:10.1080/00268979809483251 · Cited by 588
Rotational-echo double-resonance NMR
Gullion, T., & Schaefer, J. (2011) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2011.09.003 · Cited by 548
Rotational-echo double-resonance NMR
Gullion, T., & Schaefer, J. (1989) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(89)90280-1 · Cited by 504
Transferred-echo double-resonance NMR
Hing, A. W., Vega, S., & Schaefer, J. (1992) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(92)90305-q · Cited by 418
Cited by
Liang, L., Ji, Y., Chen, K., Gao, P., Zhao, Z., & Hou, G. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00779 · Cited by 57
Multiplexing experiments in NMR and multi-nuclear MRI
Kupče, E., Mote, K. R., WEBB, A. G., Madhu, P. K., & Claridge, T. D. W. (2021) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2021.03.001 · Cited by 37
Solid-State NMR of Membrane Proteins in Lipid Bilayers: To Spin or Not To Spin?
Gopinath, T., Weber, D., Wang, S., Larsen, E., & Veglia, G. (2021) · Accounts of Chemical Research · doi:10.1021/acs.accounts.0c00670 · Cited by 32
Self-citationSharma, K., Madhu, P. K., Agarwal, V., & Mote, K. R. (2020) · Journal of Biomolecular NMR · doi:10.1007/s10858-019-00292-y · Cited by 24
Reddy, U. V., Weber, D. K., Wang, S., Larsen, E. K., Gopinath, T., De Simone, A., Robia, S., & Veglia, G. (2021) · doi:10.1101/2021.05.05.442831 · Cited by 21
Self-citationGopinath, T., & Veglia, G. (2020) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2019.106664 · Cited by 18
Self-citationGopinath, T., Weber, D. K., & Veglia, G. (2020) · Journal of Biomolecular NMR · doi:10.1007/s10858-020-00316-y · Cited by 14
Self-citationAliev, A. E. (2020) · Royal Society of Chemistry eBooks · doi:10.1039/9781788010665-00139 · Cited by 11
V. S., M., Gopinath, T., Wang, S., & Veglia, G. (2019) · Scientific Reports · doi:10.1038/s41598-019-44461-3 · Cited by 9
Self-citation(2021) · Annual Reports on NMR Spectroscopy · doi:10.1016/bs.arnmr.2020.10.003 · Cited by 5
Self-citationTaware, P. P., Raran‐Kurussi, S., & Mote, K. R. (2022) · The Journal of Physical Chemistry B · doi:10.1021/acs.jpcb.2c00775 · Cited by 5
Multiple Acquisition Strategies
Traaseth, N. J. (2023) · Wiley eBooks · doi:10.1002/9781119806721.ch8 · Cited by 1
Structural and Functional Investigations of Transmembrane Signaling Histidine Kinase Using NMR
Zhang, X. (2022) · eDiss (Georg-August-Universität Göttingen) · doi:10.53846/goediss-9526
Veglia, G. (2025) · Elsevier eBooks · doi:10.1016/b978-0-323-99507-8.00011-1
Self-citation
Metadata
- Authors
- Gopinath, T., Wang, S., Lee, J., Aihara, H., & Veglia, G.
- Affiliations
- University of Minnesota (US)
- Corresponding author
- Veglia, Gianluigi
- Venue
- Journal of Biomolecular NMR
- Published
- 2019-02-25
- Volume
- 73
- Issue
- 3-4
- Pages
- 141-153
- ISSN
- 0925-2738 (ISSN-L)
- 1573-5001
- PMC
- PMC6526076
- OpenAlex
- W2915309993
- Semantic Scholar
- d9a14268a2ad86cccb6a53606c6b7aaf99885409
- Cited by
- 14
- References
- 66
- Citations by year
- 2025: 1 · 2023: 1 · 2022: 3 · 2021: 4 · 2020: 3 · 2019: 2
- FWCI
- 1.15
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- www.springer.com/tdm (tdm)
- www.springer.com/tdm (vor)
- Locations
- Journal of Biomolecular NMR (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Institute of General Medical Sciences (GM 64742, GM118047)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Advanced NMR Techniques and Applications
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Protein Structure and Dynamics
- Physical Sciences › Chemistry › Spectroscopy › Electron Spin Resonance Studies
- Keywords
- distance measurement, chemical shift assignment, ubiquitin, membrane proteins, microcrystalline proteins, fibrillar proteins
- MeSH terms
- Algorithms, Membrane Proteins, Models, Theoretical, Magnetic Resonance Spectroscopy, Proteins, Nuclear Magnetic Resonance, Biomolecular
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-11-18, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-18 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (qwen3.8-omni-flash).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.