Abstract

Ultrafast magic angle spinning (MAS) technology and 1 H detection have dramatically enhanced the sensitivity of solid-state NMR (ssNMR) spectroscopy of biopolymers. We previously showed that, when combined with polarization optimized experiments (POE), these advancements enable the simultaneous acquisition of multi-dimensional 1 H- or 13 C-detected experiments using a single receiver. Here, we propose a new sub-class within the POE family, namely HC-DUMAS, HC-MEIOSIS, and HC-MAeSTOSO, that utilize dual receiver technology for the simultaneous detection of 1 H and 13 C nuclei. We also expand this approach to record 1 H-, 13 C-, and 15 N-detected homonuclear 2D spectra simultaneously using three independent receivers. The combination of POE and multi-receiver technology will further shorten the total experimental time of ssNMR experiments for biological solids.

Overview

CoChat Summary

TL;DR

The paper introduces multi-receiver polarization optimized experiments (POE) for solid-state NMR at ultrafast magic angle spinning, enabling simultaneous 1H-, 13C-, and 15N-detected 2D spectra. It demonstrates HC-DUMAS, HC-MEIOSIS, HC-MAeSTOSO, and HCN-DUMAS on GB1 and fMLF samples, with acquisition-time savings up to 62%.

Key findings

  • HC-DUMAS acquired 2D (H)CACO and (H)NH spectra simultaneously in 23 min (0.4 h); first-increment S/N values were 23 for CO and 213 for HN, with average line widths of 55 and 242 Hz, respectively.
  • HC-MEIOSIS recorded four 2D spectra in approximately 3 h versus an estimated 7.9 h for separate acquisitions, a 62% time saving; residual polarization was about 30% for 15N, 52% for 13Cα, and 74% for 13C side-chain atoms.
  • HC-MAeSTOSO-4 acquired four 2D spectra in 3 h versus 6.29 h separately, a 53% reduction; 1D integrated S/N values were 51, 22, 34, and 100 for (H)CXCX, (H)N(CACB)H, (H)N(CA)H, and (H)NH, respectively. HC-MAeSTOSO-10 acquired four 13C- and six 1H-detected experiments in five acquisition periods, with up to 62% time saving.
  • HCN-DUMAS with triple receiver acquired 2D HH, (H)CXCX, and N(HH)N spectra of fMLF in 1.4 h; at 1 ms SIM-CP, residual 1H intensity dropped to 32% for side-chain protons and 18% for protons resonating between 3 and 10 ppm.

Methods

  • Experiments were implemented on a Bruker 600 MHz spectrometer with a 1.3 mm fast MAS probe and Avance NEO console with multi-receiver technology, using TOPSPIN 4.0.2 at a MAS rate of 65 kHz; sample temperature was 25 °C with the RF coil set to −20 °C.
  • Samples were U-13C,15N-labeled microcrystalline GB1 (2–3 mg, crystal form A) and fMLF tripeptide; recycle delays were 2 s for GB1 and 3 s for fMLF.
  • Pulse sequences combined SIM-CP, SPECIFIC-CP, DREAM, TOCSY, RFDR, and NHHN transfers; 2D data were acquired in States mode and processed with NMRPipe and Sparky.

Limitations

  • As stated: the main drawback of multi-receiver experiments is the intrinsic low sensitivity of low-γ nuclei such as 13C and 15N, requiring high scan numbers; HCN-DUMAS needs highly concentrated samples for sufficient 15N-detected S/N; broad 1H linewidths (200–400 Hz) in fully protonated samples limit HH resolution, and perdeuteration may improve 1H linewidths but lowers SIM-CP efficiency.
  • As stated: HC-MAeSTOSO-4 and HC-MAeSTOSO-10 required dummy t2 acquisition periods for unexplained execution reasons, and the water peak was not completely suppressed in HC-MAeSTOSO-10 due to additional 1H pulses for RFDR; N(HH)N feasibility for proteins is limited by poor 15N-detection sensitivity.
  • Evident from the text: demonstrations are limited to two samples (GB1 and fMLF) at 600 MHz/65 kHz; no membrane-protein or perdeuterated-sample data are shown.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1007/s10858-020-00316-y

Cites

85 of 85 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Verification

Claims the paper makes

0 Valid · 0 Not valid · 20 Not checked · 81 Own results and interpretations

46 more claims

Create a free account to see all 101 claims and to verify the 42 references still open.

See all claims — free account
  • It may state two separate claims as one. 38
  • Probably not a substantial claim. 18

Create a free account to see these claims.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

3 of 3

Citations

Cites

Show all 86 references

Cited by

See all 14

Metadata

Authors
Gopinath, T., Weber, D. K., & Veglia, G.
Affiliations
University of Minnesota (US)
Corresponding author
Veglia, Gianluigi
Venue
Journal of Biomolecular NMR
Published
2020-04-24
Volume
74
Issue
4-5
Pages
267-285
ISSN
  • 0925-2738 (ISSN-L)
  • 1573-5001
OpenAlex
W3020168848
Cited by
14
References
86
Citations by year
2025: 2 · 2024: 1 · 2023: 3 · 2022: 3 · 2021: 4 · 2020: 1
FWCI
1.01
Type
journal article
Language
en
Open access
Licence
Locations
  • Journal of Biomolecular NMR (publishedVersion)
  • PubMed (publishedVersion)
  • PubMed Central (acceptedVersion)
Funders
  • National Institute of General Medical Sciences (GM 64742)
  • National Institutes of Health (1S10OD021536)
  • National Heart, Lung, and Blood Institute (HL 144130)
  • American Heart Association (19POST34420009)
Topics
  • Physical Sciences › Chemistry › Spectroscopy › Advanced NMR Techniques and Applications
  • Physical Sciences › Chemistry › Spectroscopy › Electron Spin Resonance Studies
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
MeSH terms
Carbon Isotopes, Hydrogen, Time Factors, Nuclear Magnetic Resonance, Biomolecular

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

A language model drew the claims from the paper on 2026-11-18, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-11-18 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Multi-receiver solid-state NMR using polarization optimized experiments (POE) at ultrafast magic angle spinning. https://app.cochat.ai/papers/10.1007/s10858-020-00316-y
The paper
Gopinath, T., Weber, D. K., & Veglia, G. (2020). Multi-receiver solid-state NMR using polarization optimized experiments (POE) at ultrafast magic angle spinning. Journal of Biomolecular NMR. https://doi.org/10.1007/s10858-020-00316-y

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.