Efficacy and Safety of a New 20% Immunoglobulin Preparation for Subcutaneous Administration, IgPro20, in Patients With Primary Immunodeficiency
Open accessThe DOI matches its Crossref record.
Abstract
Subcutaneous human IgG (SCIG) therapy in primary immunodeficiency (PID) offers sustained IgG levels throughout the dosing cycle and fewer adverse events (AEs) compared to intravenous immunoglobulin (IVIG). A phase I study showed good local tolerability of IgPro20, a new 20% liquid SCIG stabilized with L-proline. A prospective, open-label, multicenter, single-arm, phase III study evaluated the efficacy and safety of IgPro20 in patients with PID over 15 months. Forty-nine patients (5-72 years) previously treated with IVIG received weekly subcutaneous infusions of IgPro20. The mean serum IgG level was 12.5 g/L. No serious bacterial infections were reported. There were 96 nonserious infections (rate 2.76/patient per year). The rate of days missed from work/school was 2.06/patient per year, and the rate of hospitalization was 0.2/patient per year. Ninety-nine percent of AEs were mild or moderate. No serious, IgPro20-related AEs were reported. IgPro20 effectively protected patients with PID against infections and maintained serum IgG levels without causing unexpected AEs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Update on the use of immunoglobulin in human disease: A review of evidence
Perez, E. E., Orange, J. S., Bonilla, F., Chinen, J., Chinn, I. K., Dorsey, M., El-Gamal, Y., Harville, T. O., Hossny, E., Mazer, B., et al. (2017) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2016.09.023 · Cited by 666
Self-citationJolles, S., Orange, J. S., Gardulf, A., Stein, M. R., Shapiro, R., Borte, M., & Berger, M. (2015) · Clinical and Experimental Immunology · doi:10.1111/cei.12485 · Cited by 179
Self-citationDoughty, D. V., Clawson, C. Z., Lambert, W., & Subramony, J. A. (2016) · Journal of Pharmaceutical Sciences · doi:10.1016/j.xphs.2016.04.009 · Cited by 74
Wasserman, R. L., Melamed, I., Stein, M. R., Engl, W., Sharkhawy, M., Leibl, H., Puck, J., Rubinstein, A., Kobrynski, L., Gupta, S., et al. (2016) · Journal of Clinical Immunology · doi:10.1007/s10875-016-0298-x · Cited by 52
“2 mL in a single infusion site was approximately 10- to 15-fold higher [23] and the median maximum infusion rate of 300 mL/h [23] was approximately 10- to 12-fold higher than the typical SC IgG infusion volume and rate [3, 12, 17, 30], rates of local AEs per infusion during IGHy treatment compare favorably with rates…”
ResultSelf-citationIgarashi, A., Kanegane, H., Kobayashi, M., Miyawaki, T., & Tsutani, K. (2014) · Clinical Therapeutics · doi:10.1016/j.clinthera.2014.08.007 · Cited by 25
Metadata
- Authors
- Hagan, J. B., Fasano, M. B., Spector, S., Wasserman, R. L., Melamed, I., Rojavin, M. A., Zenker, O., & Orange, J. S.
- Venue
- Journal of Clinical Immunology
- Published
- 2010-05-08
- Volume
- 30
- Issue
- 5
- Pages
- 734-745
- ISSN
- 0271-9142 (ISSN-L)
- 1573-2592
- OpenAlex
- W1982773941
- Cited by
- 131
- References
- 0
- FWCI
- 4.68
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Efficacy and Safety of a New 20% Immunoglobulin Preparation for Subcutaneous Administration, IgPro20, in Patients With Primary Immunodeficiency. https://app.cochat.ai/papers/10.1007/s10875-010-9423-4
- The paper
- Hagan, J. B., Fasano, M. B., Spector, S., Wasserman, R. L., Melamed, I., Rojavin, M. A., Zenker, O., & Orange, J. S. (2010). Efficacy and Safety of a New 20% Immunoglobulin Preparation for Subcutaneous Administration, IgPro20, in Patients With Primary Immunodeficiency. Journal of Clinical Immunology. https://doi.org/10.1007/s10875-010-9423-4
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.