The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Noninvasive continuous hemodynamic monitoring
Open accessAbstract
Monitoring of continuous blood pressure and cardiac output is important to prevent hypoperfusion and to guide fluid administration, but only few patients receive such monitoring due to the invasive nature of most of the methods presently available. Noninvasive blood pressure can be determined continuously using finger cuff technology and cardiac output is easily obtained using a pulse contour method. In this way completely noninvasive continuous blood pressure and cardiac output are available for clinical use in all patients that would otherwise not be monitored. Developments and state of art in hemodynamic monitoring are reviewed here, with a focus on noninvasive continuous hemodynamic monitoring form the finger.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Developed in collaboration with, European Heart Rhythm Association (EHRA), Heart Failure Association (HFA), and Heart Rhythm Society (HRS), societies, E. B. T. F., European Society of Emergency Medicine (EuSEM), European Federation of Internal Medicine (EFIM), European Union Geriatric Medicine Society (EUGMS), American Geriatrics Society (AGS), European Neurological Society (ENS), et al. (2009) · European Heart Journal · doi:10.1093/eurheartj/ehp298 · Cited by 2,040
Syncope, cerebral perfusion, and oxygenation
Van Lieshout, J. J., Wieling, W., Karemaker, J. M., & Secher, N. H. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00260.2002 · Cited by 365
Bur, A., Hirschl, M. M., Herkner, H., Oschatz, E., Kofler, J., Woisetschläger, C., & Laggner, A. N. (2000) · Critical Care Medicine · doi:10.1097/00003246-200002000-00014 · Cited by 154
Cited by
Noninvasive continuous cardiac output monitoring in perioperative and intensive care medicine
Saugel, B., Cecconi, M., Wagner, J. Y., & Reuter, D. A. (2015) · British Journal of Anaesthesia · doi:10.1093/bja/aeu447 · Cited by 268
Peter, L., Noury, N., & Cerny, M. (2014) · IRBM · doi:10.1016/j.irbm.2014.07.002 · Cited by 261
Metadata
- Authors
- Truijen, J., van Lieshout, J. J., Wesselink, W. A., & Westerhof, B. E.
- Venue
- Journal of Clinical Monitoring and Computing
- Published
- 2012-06-14
- Volume
- 26
- Issue
- 4
- Pages
- 267-278
- ISSN
- 1387-1307 (ISSN-L)
- 1573-2614
- OpenAlex
- W2053553510
- Cited by
- 161
- References
- 3
- FWCI
- 13.23
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Noninvasive continuous hemodynamic monitoring. https://app.cochat.ai/papers/10.1007/s10877-012-9375-8
- The paper
- Truijen, J., van Lieshout, J. J., Wesselink, W. A., & Westerhof, B. E. (2012). Noninvasive continuous hemodynamic monitoring. Journal of Clinical Monitoring and Computing. https://doi.org/10.1007/s10877-012-9375-8
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.