Accuracy of oscillometric blood pressure measurement according to the relation between cuff size and upper-arm circumference in critically ill patients
Abstract
OBJECTIVE: To evaluate the accuracy of oscillometric blood pressure measurement according to the relation between cuff size and upper-arm circumference in critically ill patients. DESIGN: Prospective data collection. SETTING: Emergency department in a 2,000-bed inner city hospital. PATIENTS: Thirty-eight patients categorized into three groups according to their upper-arm circumference (group I: 18-25 cm; group II: 25.1-33 cm; and group III: 33.1-47.5 cm) were enrolled in the study protocol. INTERVENTIONS: In each patient, all three cuff sizes (Hewlett-Packard Cuff 40401 B, C, and D) were used to perform an oscillometric blood pressure measurement at least within 3 mins until ten to 20 measurements for each cuff size were achieved. Invasive mean arterial blood pressure measurement was done by cannulation of the contralateral radial artery with direct transduction of the systemic arterial pressure waveform. The corresponding invasive blood pressure value was obtained at the end of each oscillometric measurement. MEASUREMENT AND MAIN RESULTS: Overall, 1,494 pairs of simultaneous oscillometric and invasive blood pressure measurements were collected in 38 patients (group I, n = 5; group II, n = 23; and group III, n = 10) over a total time of 72.3 hrs. Mean arterial blood pressure ranged from 35 to 165 mm Hg. The overall discrepancy between oscillometric and invasive blood pressure measurement was -6.7+/-9.7 mm Hg (p<.0001), if the recommended cuff size according to the upper-arm circumference was used (539 measurements). Of all the blood pressure measurements, 26.4% (n = 395) had a discrepancy of > or =10 mm Hg and 34.2% (n = 512) exhibited a discrepancy of > or =20 mm Hg. No differences between invasive and noninvasive blood pressure measurements were noted in patients either with or without inotropic support (-6.6 + 7.2 vs. -8.6 + 6.8 mm Hg; not significant). CONCLUSION: The oscillometric blood pressure measurement significantly underestimates arterial blood pressure and exhibits a high number of measurements out of the clinically acceptable range. The relation between cuff size and upper-arm circumference contributes substantially to the inaccuracy of the oscillometric blood pressure measurement. Therefore, oscillometric blood pressure measurement does not achieve adequate accuracy in critically ill patients.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Specialist consultation appears to be associated with improved patient outcomes for a variety of infectious syndromes.
“Specialist consultation appears to be associated with improved patient outcomes for a variety of infectious syndromes (295-300).”
From Surviving Sepsis Campaign: International Guidelines for Management of Sepsis and Septic Shock 2021. (2021) · cites this paper as [300]
Non-invasive cuff blood pressure estimation tends to be inaccurate, with discrepancy more pronounced in shock states.
“Estimation of blood pressure using a non-invasive cuff tends to be inaccurate and the discrepancy more pronounced in shock states [375–379].”
From Surviving sepsis campaign: international guidelines for management of sepsis and septic shock 2021 (2021) · cites this paper as [376]
Cites
Knaus, W. A., Draper, E. A., Wagner, D. P., & Zimmerman, J. E. (1985) · Critical Care Medicine · doi:10.1097/00003246-198510000-00009 · Cited by 15,333 · see citing works
APACHE II-A Severity of Disease Classification System
Knaus, W. A., Draper, E. A., Wagner, D. P., & Zimmerman, J. E. (1986) · Critical Care Medicine · doi:10.1097/00003246-198608000-00028 · Cited by 13,379 · see citing works
Direct Blood Pressure Measurement —Dynamic Response Requirements
Gardner, R. M. (1981) · Anesthesiology · doi:10.1097/00000542-198103000-00010 · Cited by 522 · see citing works
On the Safety of Radial Artery Cannulation
Slogoff, S., Keats, A. S., & Arlund, C. (1983) · Anesthesiology · doi:10.1097/00000542-198307000-00008 · Cited by 361 · see citing works
Comparison of Indirect and Direct Methods of Measuring Arterial Blood Pressure
BERGEN, F. H. V., WEATHERHEAD, D. S., Treloar, A. E., Dobkin, A. B., & Buckley, J. J. (1954) · Circulation · doi:10.1161/01.cir.10.4.481 · Cited by 193 · see citing works
INVASIVE V. NON-INVASIVE MEASUREMENT OF ARTERIAL PRESSURE
van Egmond, J., Hasenbos, M. A. W. M., & Crul, J. F. (1985) · British Journal of Anaesthesia · doi:10.1093/bja/57.4.434 · Cited by 129 · see citing works
The Accuracy of Finapres™ Noninvasive Mean Arterial Pressure Measurements in Anesthetized Patients
Gibbs, N. M., Larach, D. R., & Derr, J. A. (1991) · Anesthesiology · doi:10.1097/00000542-199104000-00004 · Cited by 65 · see citing works
Imai, Y., Abe, K., Miura, Y., et al. (1988) · Journal of Hypertension · doi:10.1097/00004872-198801000-00003 · Cited by 57 · see citing works
Runcie, C. J., Reeve, W., Reidy, J., & Dougall, J. (1990) · Anaesthesia · doi:10.1111/j.1365-2044.1990.tb14393.x · Cited by 51 · see citing works
Bur, A., Müllner, M., Sterz, F. R., et al. (1997) · PubMed · Cited by 42 · see citing works
Self-citationCohen, A., Reyes, R., KIRK, M., et al. (1984) · Critical Care Medicine · doi:10.1097/00003246-198412000-00017 · Cited by 37 · see citing works
Hirschl, M. M., Binder, M., Herkner, H., et al. (1996) · Critical Care Medicine · doi:10.1097/00003246-199610000-00014 · Cited by 36 · see citing works
Self-citationPost-cannulation radial artery aneurysm — a rare complication
McEllistrem, R. F., O’Toole, D. P., & Keane, P. (1990) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03006633 · Cited by 35 · see citing works
Arterial occlusion after cannulation.
Evans, P. J., & Kerr, J. (1975) · BMJ · doi:10.1136/bmj.3.5977.197 · Cited by 35 · see citing works
Accuracy of four indirect methods of blood pressure measurement, with hemodynamic correlations
Gravlee, G. P., & Brockschmidt, J. K. (1990) · Journal of Clinical Monitoring and Computing · doi:10.1007/bf02842488 · Cited by 35 · see citing works
Gevers, M., van Genderingen, H. R., Lafeber, H. N., & Hack, W. W. M. (1996) · Intensive Care Medicine · doi:10.1007/bf01712244 · Cited by 32 · see citing works
A Comparison of Two Automated Indirect Arterial Blood Pressure Meters
Nyström, E. E. L., REID, K. H., BENNETT, R., et al. (1985) · Anesthesiology · doi:10.1097/00000542-198504000-00030 · Cited by 32 · see citing works
CARDIOVASCULAR MONITORING IN PATIENTS WITH VASCULAR DISEASE
Prys-Roberts, C. (1981) · British Journal of Anaesthesia · doi:10.1093/bja/53.7.767 · Cited by 26 · see citing works
A comparison of intra-arterial and auscultatory blood pressure readings.
Chyun, D. (1985) · PubMed · Cited by 15 · see citing works
[Isovolemic hemodilution in coronary heart disease--clinical and hemodynamic effects].
Neubaur, T., Peters, A., Schöbel, F. C., et al. (1996) · PubMed · Cited by 15 · see citing works
A quantitative evaluation of the Hewlett-Packard 78354A noninvasive blood pressure meter
Whalen, P., & Ream, A. K. (1988) · Journal of Clinical Monitoring and Computing · doi:10.1007/bf01618104 · Cited by 9 · see citing works
Zur Me�sicherheit der oszillometrischen Blutdruckme�ger�te Dinamap 1846 und HP M-1008B
Papadopoulos, G., Mieke, S., Kuhn, H.-J., et al. (1996) · Der Anaesthesist · doi:10.1007/s001010050280 · Cited by 8 · see citing works
Mean blood pressure algorithms
Ream, A. K. (1985) · The Journal of Clinical Monitoring · doi:10.1007/bf02832203 · Cited by 8 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Surviving Sepsis Campaign: International Guidelines for Management of Sepsis and Septic Shock 2021.
Evans, L., Rhodes, A., Alhazzani, W., Antonelli, M., Coopersmith, C. M., French, C., Machado, F. R., Mcintyre, L., Ostermann, M., Prescott, H. C., et al. (2021) · Critical Care Medicine · doi:10.1097/ccm.0000000000005337 · Cited by 2,935 · see citing works
Methods of Blood Pressure Measurement in the ICU*
Lehman, L.-W. H., Saeed, M., Talmor, D., Mark, R., & Malhotra, A. (2013) · Critical Care Medicine · doi:10.1097/ccm.0b013e318265ea46 · Cited by 224 · see citing works
Surviving sepsis campaign: international guidelines for management of sepsis and septic shock 2021
Evans, L., Rhodes, A., Alhazzani, W., Antonelli, M., Coopersmith, C. M., French, C., Machado, F. R., Mcintyre, L., Ostermann, M., Prescott, H. C., et al. (2021) · Intensive Care Medicine · doi:10.1007/s00134-021-06506-y · Cited by 5,082 · see citing works
Arterial blood pressure monitoring in overweight critically ill patients: invasive or noninvasive?
Araghi, A., Bander, J. J., & Guzman, J. A. (2006) · Critical Care · doi:10.1186/cc4896 · Cited by 115 · see citing works
Surviving Sepsis campaign: international guidelines for Management of Sepsis and Septic Shock 2026
Prescott, H. C., Antonelli, M., Alhazzani, W., Møller, M. H., Alshamsi, F., Azevedo, L. C. P., Belley-Cote, E., De Waele, J., Derde, L., Dionne, J. C., et al. (2026) · Critical Care Medicine · doi:10.1097/ccm.0000000000007075 · Cited by 117 · see citing works
Riley, L. E., Chen, G. J., & Latham, H. E. (2017) · Blood Pressure Monitoring · doi:10.1097/mbp.0000000000000258 · Cited by 43 · see citing works
- Authors
- Bur, A., Hirschl, M. M., Herkner, H., Oschatz, E., Kofler, J., Woisetschläger, C., & Laggner, A. N.
- Affiliations
- Vienna General Hospital (AT)
- Venue
- Critical Care Medicine
- Published
- 2000-02
- Volume
- 28
- Issue
- 2
- Pages
- 371-376
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W1968250575
- Cited by
- 154
- References
- 23
- Citations by year
- 2026: 4 · 2025: 7 · 2024: 4 · 2023: 5 · 2022: 8 · 2021: 9 · 2020: 5 · 2019: 7 · 2018: 7 · 2017: 7 · 2016: 9 · 2015: 4 · 2014: 11 · 2013: 7 · 2012: 10
- FWCI
- 1.42
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Critical Care Medicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- oscillometric blood pressure measurement, cuff size, upper arm circumference, measurement accuracy, critically ill patients, invasive blood pressure, mean arterial pressure, inotropic support, non-invasive blood pressure monitoring, emergency department patients, radial artery cannulation, hemodynamic monitoring, in-hospital mortality, length of hospital stay
- MeSH terms
- Adolescent, Adult, Aged, Aged, 80 and over, Anthropometry, Arm, Blood Pressure Determination, Equipment Design, Equipment Failure, Female, Humans, Male, Middle Aged, Monitoring, Physiologic, Oscillometry, Prospective Studies, Reproducibility of Results, Bias, Linear Models, Critical Illness
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review