Comparison of two devices using near-infrared spectroscopy for the measurement of tissue oxygenation during a vascular occlusion test in healthy volunteers (INVOS® vs. InSpectra™)
The DOI matches its Crossref record; 38 of the 39 references it cites were found in a registry or an index.
Abstract
The aim of this study was to compare tissue oxygen saturation as measured by INVOS® and InSpectra™ during a vascular occlusion test (VOT) in the same subject. Twenty healthy adults were investigated. The INVOS® and InSpectra™ probes were placed randomly on the right and left thenar eminence in the same participant and monitoring of tissue oxygen saturation (SrO2 from INVOS® and StO2 from InSpectra™) were begun. Pneumatic cuffs placed around each upper arm were inflated simultaneously to 30 mmHg above the initial systolic blood pressure and maintained until the tissue oxygen saturation had decreased to 40% or below. The cuff pressure was then released rapidly. The time to achieve initial stability, the baseline value, the time from the baseline value to 40%, the rate of deoxygenation, the rate of reoxygenation, and the hyperemic area under the curve were calculated from SrO2 and StO2. The baseline value by INVOS® was lower than that by InSpectra™ (75.6±8.2 vs. 81.8±3.4%, p<0.01). The time to reach stable baseline value was significantly longer for SrO2 than for StO2 (249±86 and 54±40 s respectively; p<0.01). SrO2 declined to 40% more rapidly than did the StO2 (147±38 vs. 199±41 s, p<0.01). The deoxygenation and reoxygenation rates were higher (p<0.01) and the reactive hyperemic area was more extensive for INVOS® than for InSpectra™ (p=0.015). In conclusion, the VOT on the thenar muscle using INVOS® was as clinically applicable as InSpectra™, but baseline values and dynamic cha…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Statistical normalization approaches, such as a physiological calibration, are then often used to address these problems.7,9,12”
From Near-infrared spectroscopy-derived muscle oxygen saturation on a 0% to 100% scale: reliability and validity of the Moxy Monitor (2019) · cites this paper as [9]
In the citing paper
“However, large manufacturer differences, including inter-optode distance, number of wavelengths used, spectral width, and algorithmic calculations, all raise questions about the scaling of SmO2 and TOI.7–9”
From Near-infrared spectroscopy-derived muscle oxygen saturation on a 0% to 100% scale: reliability and validity of the Moxy Monitor (2019) · cites this paper as [9]
In the citing paper
“While this advancement has helped in the scaling of NIRS, when looking at device comparison data from this experiment, or alternative studies,7–9 clearly a functional scale has not been determined.”
From Near-infrared spectroscopy-derived muscle oxygen saturation on a 0% to 100% scale: reliability and validity of the Moxy Monitor (2019) · cites this paper as [9]
In the citing paper
“Past studies comparing NIRS monitors have highlighted discrepancies in the values obtained at rest and during exercise in human 11 -14 and animal 15 systems.”
From Performance comparison of the MOXY and PortaMon near-infrared spectroscopy muscle oximeters at rest and during exercise (2018) · cites this paper as [12]
Citations
Cites
Near-infrared spectroscopy as an index of brain and tissue oxygenation
Murkin, J. M., & Arango, M. (2009) · British Journal of Anaesthesia · doi:10.1093/bja/aep299 · Cited by 877
Validation of near-infrared spectroscopy in humans
Mancini, D. M., Bolinger, L., Li, H., Kendrick, K., Chance, B., & Wilson, J. R. (1994) · Journal of Applied Physiology · doi:10.1152/jappl.1994.77.6.2740 · Cited by 669
Scheeren, T. W. L., Schober, P., & Schwarte, L. A. (2012) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-012-9348-y · Cited by 478
Duncan, A., Meek, J. H., Clemence, M., Elwell, C. E., Fallon, P., Tyszczuk, L., Cope, M., & Delpy, D. T. (1996) · Pediatric Research · doi:10.1203/00006450-199605000-00025 · Cited by 469
Lima, A. A. P., van Bommel, J., Jansen, T. C., İnce, C., & Bakker, J. (2009) · Critical Care · doi:10.1186/cc8011 · Cited by 437
Noninvasive monitoring of peripheral perfusion
Lima, A., & Bakker, J. (2005) · Intensive Care Medicine · doi:10.1007/s00134-005-2790-2 · Cited by 409
The prognostic value of muscle StO2 in septic patients
Creteur, J., Carollo, T., Soldati, G., Buchele, G., De Backer, D., & Vincent, J.-L. (2007) · Intensive Care Medicine · doi:10.1007/s00134-007-0739-3 · Cited by 355
Near‐infrared spectroscopy for monitoring muscle oxygenation
Boushel, R., & Piantadosi, C. A. (2000) · Acta Physiologica Scandinavica · doi:10.1046/j.1365-201x.2000.00713.x · Cited by 299
Cohn, S. M., Nathens, A. B., Moore, F. A., Rhee, P., Puyana, J. C., Moore, E. E., & Beilman, G. J. (2007) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/ta.0b013e31802eb817 · Cited by 294
McNeill, S., Gatenby, J. C., McElroy, S., & Engelhardt, B. (2011) · Journal of Perinatology · doi:10.1038/jp.2010.71 · Cited by 212
Cited by
McManus, C. J., Collison, J., & Cooper, C. E. (2018) · Journal of Biomedical Optics · doi:10.1117/1.jbo.23.1.015007 · Cited by 205
Feldmann, A., Schmitz, R. W., & Erlacher, D. (2019) · Journal of Biomedical Optics · doi:10.1117/1.jbo.24.11.115001 · Cited by 203
“Statistical normalization approaches, such as a physiological calibration, are then often used to address these problems.(7,9,12) The situation becomes even more complicated as no consensus “gold standard” for NIRS-derived values exists to compare against.”
MethodSteenhaut, K., Lapage, K., Bové, T., De Hert, S., & Moerman, A. (2017) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-016-9962-1 · Cited by 41
Niezen, C. K., Massari, D., Vos, J. J., & Scheeren, T. (2022) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-021-00779-w · Cited by 26
Scheeren, T. (2016) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-016-9846-4 · Cited by 22
The vascular occlusion test using multispectral imaging: a validation study
Bruins, A. A., Geboers, D. G. P. J., Bauer, J. R., Klaessens, J. H. G. M., Verdaasdonk, R. M., & Boer, C. (2020) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-019-00448-z · Cited by 19
Mitochondrial Oxygenation During Cardiopulmonary Bypass: A Pilot Study
Harms, F. A., Ubbink, R., de Wijs, C. J., Ligtenberg, M., ter Horst, M., & Mik, E. G. (2022) · Frontiers in Medicine · doi:10.3389/fmed.2022.785734 · Cited by 17
Scholkmann, F., & Vrana, A. (2020) · Advances in experimental medicine and biology · doi:10.1007/978-3-030-34461-0_32 · Cited by 17
Lee, J., Jang, Y., Song, I., Kim, E., Kim, H., & Kim, J. (2017) · Pediatric Critical Care Medicine · doi:10.1097/pcc.0000000000001386 · Cited by 15
Self-citationKeuler, J., Weiß, C., Klemm, K., Pochhammer, J., Schmidt, R., & Ilies, C. (2018) · European Journal of Anaesthesiology · doi:10.1097/eja.0000000000000871 · Cited by 13
Chung, J., Ji, S., Jang, Y., Kim, E., Lee, J., Kim, J., & Kim, H. (2020) · Journal of Vascular Research · doi:10.1159/000510072 · Cited by 12
Self-citationLee, Y. S., Kim, W. Y., Yoo, J. W., Jung, H. D., & Min, T. J. (2018) · Korean Journal of Anesthesiology · doi:10.4097/kja.d.17.00002 · Cited by 12
Cournoyer, A., Denault, A. Y., Cossette, S., Fortier, A., Daoust, R., Iseppon, M., Chauny, J., & Notebaert, É. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.9.097003 · Cited by 9
Cho, A.-R., Lee, H. J., Hong, J.-M., Kang, C., Kim, H. J., Kim, E.-J., Kim, M. S., Jeon, S., & Hwang, H. (2022) · Korean Journal of Anesthesiology · doi:10.4097/kja.22097 · Cited by 7
Self-citationCusack, R. A. F., Rodríguez, A. H., Cantan, B., Miskolci, O., Connolly, E. M., Zilahi, G., Coakley, J. D., & Martín‐Loeches, I. (2025) · Journal of Clinical Medicine · doi:10.3390/jcm14144982 · Cited by 6
Zanoletti, M., Yaqub, M. A., Cortese, L., Buttafava, M., García, J. M., Amendola, C., Carteano, T., Frabasile, L., García, D. S., Guadagno, C. N., et al. (2025) · Journal of Biomedical Optics · doi:10.1117/1.jbo.30.11.115004 · Cited by 3
Interplay Among Muscle Oxygen Saturation, Activation, and Power on a Swim-Bench
Coloretti, V., Quagliarotti, C., Gatta, G., Piacentini, M. F., Cortesi, M., & Fantozzi, S. (2025) · Sensors · doi:10.3390/s25134148 · Cited by 1
Circumferential compression of the lower limb and implications for soft exoskeleton design
Kermavnar, T. (2019) · Arrow@dit (Dublin Institute of Technology) · doi:10.34961/8582 · Cited by 1
Dietze, Z., von ASPERN, K., Haunschild, J., Oßmann, S., Borger, M. A., & Etz, C. D. (2022) · Research Square · doi:10.21203/rs.3.rs-1728216/v1
Ларин, И. В., Shchanitsyn, I. N., Толстокоров, А. С., Бажанов, С. П., & Кожевников, И. О. (2023) · Clinical Physiology of Circulation · doi:10.24022/1814-6910-2023-20-2-155-163
Guo, F., Jia, S., Wang, Q., Liu, Q., Hu, M., Wang, W., Liu, S., Li, Q., Lu, B., & Zheng, Y. (2021) · Research Square · doi:10.21203/rs.3.rs-903012/v1
Ökmen, K., Uçar, Ş. B., Yıldız, D. K., Uçar, M. H., & Doğan, A. K. (2025) · Journal of Laparoendoscopic & Advanced Surgical Techniques · doi:10.1089/lap.2025.0062
Оптическая тканевая оксиметрия: проблемы применения в функциональной диагностике
П., Т. А., И., Е. А., & В., Д. Д. (2017) · Medical alphabet
Aizimu, T., Adachi, M., Nakano, K., Ohnishi, T., Nakaguchi, T., Takahashi, N., Nakada, T., Oda, S., & Haneishi, H. (2018) · Optical Diagnostics and Sensing: Toward Point-of-Care Diagnostics · doi:10.1117/12.2291186
Panula, T., Mustajoki, I., Jaakola, T., Niemi, T. S., & Kaisti, M. (2025) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2025.118163
Karataş, S., Atlas, A., Şengel, A., Altay, N., & Büyükfırat, E. (2026) · Journal of Anesthesiology and Reanimation Specialists’ Society · doi:10.54875/jarss.2026.74507
Metadata
- Authors
- Lee, J.-H., Park, Y.-H., Kim, H.-S., & Kim, J.-T.
- Affiliations
- Seoul National University (KR)
- Chung-Ang University Hospital (KR)
- Corresponding author
- Kim, Jin-Tae
- Venue
- Journal of Clinical Monitoring and Computing
- Published
- 2014-07-09
- Volume
- 29
- Issue
- 2
- Pages
- 271-278
- ISSN
- 1387-1307 (ISSN-L)
- 1573-2614
- OpenAlex
- W2081435339
- Semantic Scholar
- e192e4fae3716668518bf48ffc9662cf0781ec09
- Cited by
- 20
- References
- 39
- Citations by year
- 2025: 5 · 2022: 3 · 2020: 2 · 2019: 2 · 2018: 4 · 2017: 1 · 2016: 3
- FWCI
- 1.04
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Journal of Clinical Monitoring and Computing (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Infrared Thermography in Medicine
- Keywords
- near-infrared spectroscopy, tissue oxygen saturation, vascular occlusion test, device comparison, reactive hyperemia, thenar muscles, cuff inflation
- MeSH terms
- Adult, Female, Humans, Male, Oximetry, Oxygen, Reference Values, Sensitivity and Specificity, Reproducibility of Results, Muscle, Skeletal, Spectroscopy, Near-Infrared
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.