Cited by 669Optical Imaging and Spectroscopy TechniquesCardiovascular and exercise physiologyNon-Invasive Vital Sign Monitoring

Validation of near-infrared spectroscopy in humans

Mancini, D. M., Bolinger, L., Li, H., Kendrick, K., Chance, B., Wilson, J. R.·1994·Journal of Applied Physiology

Abstract

Near-infrared (NIR) spectroscopy is a noninvasive technique that uses the differential absorption properties of hemoglobin to evaluate skeletal muscle oxygenation. Oxygenated and deoxygenated hemoglobin absorb light equally at 800 nm, whereas at 760 nm absorption is primarily from deoxygenated hemoglobin. Therefore, monitoring these two wavelengths provides an index of deoxygenation. To investigate whether venous oxygen saturation and absorption between 760 and 800 nm (760-800 nm absorption) are correlated, both were measured during forearm exercise. Significant correlations were observed in all subjects (r = 0.92 +/- 0.07; P < 0.05). The contribution of skin flow to the changes in 760-800 nm absorption was investigated by simultaneous measurement of skin flow by laser flow Doppler and NIR recordings during hot water immersion. Changes in skin flow but not 760-800 nm absorption were noted. Intra-arterial infusions of nitroprusside and norepinephrine were performed to study the effect of alteration of muscle perfusion on 760-800 nm absorption. Limb flow was measured with venous plethysmography. Percent oxygenation increased with nitroprusside and decreased with norepinephrine. Finally, the contribution of myoglobin to the 760-800 nm absorption was assessed by using 1H-magnetic resonance spectroscopy. At peak exercise, percent NIR deoxygenation during exercise was 80 +/- 7%, but only one subject exhibited a small deoxygenated myoglobin signal. In conclusion, 760-800 nm absorpti…

Integrity signals

Registry

Crossref · 10.1152/jappl.1994.77.6.2740

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

No citation lists for this paper

No citation lists for this paper yet — checked again daily.

Cited by 669

Authors
Mancini, D. M., Bolinger, L., Li, H., Kendrick, K., Chance, B., & Wilson, J. R.
Affiliations
Hospital of the University of Pennsylvania (US)
Venue
Journal of Applied Physiology
Published
1994-12-01
Volume
77
Issue
6
Pages
2740-2747
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W1914691075
Cited by
669
References
0
Citations by year
2026: 7 · 2025: 11 · 2024: 14 · 2023: 16 · 2022: 17 · 2021: 17 · 2020: 20 · 2019: 28 · 2018: 14 · 2017: 31 · 2016: 28 · 2015: 24 · 2014: 25 · 2013: 36 · 2012: 36
FWCI
8.80
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Applied Physiology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
  • Health Sciences › Medicine › Complementary and alternative medicine › Cardiovascular and exercise physiology
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
Keywords
near-infrared spectroscopy, skeletal muscle oxygenation, deoxyhemoglobin, venous oxygen saturation, skin blood flow, limb perfusion, sodium nitroprusside, norepinephrine, myoglobin, forearm exercise, hot water immersion
MeSH terms
Absorption, Adult, Forearm, Hemoglobins, Humans, Infrared Rays, Myoglobin, Magnetic Resonance Spectroscopy, Oxygen, Regional Blood Flow, Skin, Veins, Muscle, Skeletal

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›