Cited by 35Machine Learning in HealthcareNon-Invasive Vital Sign MonitoringHealthcare Technology and Patient Monitoring

Predicting vital sign deterioration with artificial intelligence or machine learning

Open access
Vistisen, Simon T., Johnson, Alistair E. W., Scheeren, Thomas W. L.·2019·Journal of Clinical Monitoring and Computing

Abstract

of authors shown on this cover page is limited to 10 maximum.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s10877-019-00343-7

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Multivariate regression-based models or AI-based early-warning systems have the potential to detect subtle trends in physiologic parameters over time to provide precision and reliability.

    “Multivariate regression-based models or AI-based early-warning systems have the potential to detect subtle trends in physiologic parameters over time to provide precision and reliability (38–41).”
  • Preventative measures may be taken earlier and with more accuracy if AI metrics are implemented as opposed to traditional risk-evaluation scores.

    “Preventative measures may be taken earlier and with more accuracy if AI metrics are implemented as opposed to the traditional risk-evaluation scores (40, 42).”
  • Vital sign monitoring and alarms are effective in alerting providers to discrete vital sign abnormalities in real time, but early or isolated vital sign abnormalities may fail to signal impending decompensation.

    “They are effective in alerting providers to discrete vital sign abnormalities in real time; however, early or isolated vital sign abnormalities also may fail to signal to providers an impending decompensation (40).”
  • Vital sign monitoring and associated alarms were one of the earliest methods to detect patient decompensation.

    “Vital sign monitoring and associated alarms were one of the earliest methods to detect patient decompensation (40).”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

1 of the 5 references couldn’t be matched to a known paper.

Cited by

Sorted by citations

Authors
Vistisen, S. T., Johnson, A. E. W., & Scheeren, T. W. L.
Affiliations
  • Aarhus University (DK)
  • Massachusetts Institute of Technology (US)
  • University Medical Center Groningen (NL)
Corresponding author
Scheeren, Thomas W. L.
Venue
Journal of Clinical Monitoring and Computing
Published
2019-06-28
Volume
33
Issue
6
Pages
949-951
ISSN
  • 1387-1307 (ISSN-L)
  • 1573-2614
OpenAlex
W2954704200
Cited by
35
References
5
Citations by year
2026: 2 · 2025: 4 · 2024: 4 · 2023: 5 · 2022: 5 · 2021: 7 · 2020: 7 · 2019: 1
Type
journal article
Language
en
Open access
Locations
  • Journal of Clinical Monitoring and Computing (publishedVersion, other-oa)
  • PubMed (publishedVersion)
  • University of Groningen research database (University of Groningen / Centre for Information Technology) (publishedVersion, other-oa)
  • DSpace@MIT (Massachusetts Institute of Technology) (submittedVersion, cc-by-nc)
  • University of Groningen research database (University of Groningen / Centre for Information Technology) (submittedVersion, other-oa)
Topics
  • Physical Sciences › Computer Science › Artificial Intelligence › Machine Learning in Healthcare
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Surgery › Healthcare Technology and Patient Monitoring
Keywords
early warning scores, machine learning, artificial intelligence, clinical deterioration prediction, patient monitoring
MeSH terms
Machine Learning, Artificial Intelligence, Humans, Intensive Care Units, Tachycardia

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review