The DOI matches its Crossref record; 142 of the 142 references it cites were found in a registry or an index.
Smart Health Monitoring Systems: An Overview of Design and Modeling
Abstract
Health monitoring systems have rapidly evolved during the past two decades and have the potential to change the way health care is currently delivered. Although smart health monitoring systems automate patient monitoring tasks and, thereby improve the patient workflow management, their efficiency in clinical settings is still debatable. This paper presents a review of smart health monitoring systems and an overview of their design and modeling. Furthermore, a critical analysis of the efficiency, clinical acceptability, strategies and recommendations on improving current health monitoring systems will be presented. The main aim is to review current state of the art monitoring systems and to perform extensive and an in-depth analysis of the findings in the area of smart health monitoring systems. In order to achieve this, over fifty different monitoring systems have been selected, categorized, classified and compared. Finally, major advances in the system design level have been discussed, current issues facing health care providers, as well as the potential challenges to health monitoring field will be identified and compared to other similar systems.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Based on the literature, most monitoring applications which consider home settings or remote monitoring deal predominantly with prediction and anomaly detection whereas the applications in clinical settings are typically focused on diagnosis [10,21].”
From Data Mining for Wearable Sensors in Health Monitoring Systems: A Review of Recent Trends and Challenges (2013) · cites this paper as [10]
Citations
Cites
Measuring balance in the elderly: preliminary development of an instrument
Berg, K. (1989) · Physiotherapy Canada · doi:10.3138/ptc.41.6.304 · Cited by 2,746
A Survey on Wearable Sensor-Based Systems for Health Monitoring and Prognosis
Pantelopoulos, A., & Bourbakis, N. G. (2010) · IEEE Transactions on Systems Man and Cybernetics Part C (Applications and Reviews) · doi:10.1109/tsmcc.2009.2032660 · Cited by 2,296
Balance in elderly patients: the "get-up and go" test.
Mathias, S., Nayak, U. S., & Isaacs, B. (1986) · PubMed · Cited by 1,539
The costs of fatal and non-fatal falls among older adults
Stevens, J. A., Corso, P. S., Finkelstein, E. A., & Miller, T. R. (2006) · Injury Prevention · doi:10.1136/ip.2005.011015 · Cited by 1,494
Masud, T., & Morris, R. O. (2001) · Age and Ageing · doi:10.1093/ageing/30.suppl_4.3 · Cited by 939
Wootton, R. (2001) · BMJ · doi:10.1136/bmj.323.7312.557 · Cited by 715
Security and Privacy Issues in Wireless Sensor Networks for Healthcare Applications
Ameen, M. A., Liu, J., & Kwak, K. (2010) · Journal of Medical Systems · doi:10.1007/s10916-010-9449-4 · Cited by 671
Monitoring Motor Fluctuations in Patients With Parkinson's Disease Using Wearable Sensors
Patel, S., Lorincz, K., Hughes, R., Huggins, N., Growdon, J., Standaert, D., Akay, M., Dy, J., Welsh, M., & Bonato, P. (2009) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2033471 · Cited by 623
Elderly persons’ perception and acceptance of using wireless sensor networks to assist healthcare
Steele, R., Lo, A., Secombe, C., & Wong, Y. K. (2009) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2009.08.001 · Cited by 508
Smart Vest: Wearable multi-parameter remote physiological monitoring system
Pandian, P. S., Mohanavelu, K., Safeer, K. P., Kotresh, T. M., Shakunthala, D. T., Gopal, P., & Padaki, V. C. (2007) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2007.05.014 · Cited by 420
Research works printed but not linked: 2
- Williams, J., Wireless in Healthcare: A Study Tracking the Use of RFID, Wireless Sensor Solutions, and Telemetry Technologies by Medical Device Manufacturers and Healthcare Providers. The FocalPoint Group, USA, 2004.
- Logan, A. G., McIsaac, W. J., Tisler, A., Irvine, M. J., Saunders, A., Dunai, A., Rizo, C. A., Feig, D. S., Hamill, M., and Trudel, M., Mobile phone-based remote patient monitoring system for management of hypertension in diabetic patients. Am. J. Hypertens. 20(9):942–948, 2007. · DOI
Cited by
Sorted by citations
The use of photoplethysmography for assessing hypertension
Elgendi, M., Fletcher, R., Liang, Y., Howard, N., Lovell, N. H., Abbott, D., Lim, K., & Ward, R. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0136-7 · Cited by 625
Remote patient monitoring: a comprehensive study
Malasinghe, L. P., Ramzan, N., & Dahal, K. (2019) · Journal of Ambient Intelligence and Humanized Computing · doi:10.1007/s12652-017-0598-x · Cited by 534
Banaee, H., Ahmed, M., & Loutfi, A. (2013) · Sensors · doi:10.3390/s131217472 · Cited by 452
Baig, M. M., GholamHosseini, H., Moqeem, A. A., Mirza, F., & Lindén, M. (2017) · Journal of Medical Systems · doi:10.1007/s10916-017-0760-1 · Cited by 351
Self-citationSmart health: Big data enabled health paradigm within smart cities
Pramanik, M. I., Lau, R. Y. K., Demirkan, H., & Azad, M. A. K. (2017) · Expert Systems with Applications · doi:10.1016/j.eswa.2017.06.027 · Cited by 341
Metadata
- Authors
- Baig, M. M., & Gholamhosseini, H.
- Affiliations
- Auckland University of Technology (NZ)
- Corresponding author
- Baig, Mirza Mansoor
- Venue
- Journal of Medical Systems
- Published
- 2013-01-15
- Volume
- 37
- Issue
- 2
- Pages
- 9898-9898
- ISSN
- 0148-5598 (ISSN-L)
- 1573-689X
- OpenAlex
- W2019110265
- Cited by
- 396
- References
- 141
- Citations by year
- 2026: 14 · 2025: 12 · 2024: 21 · 2023: 27 · 2022: 26 · 2021: 38 · 2020: 39 · 2019: 52 · 2018: 42 · 2017: 43 · 2016: 30 · 2015: 26 · 2014: 21 · 2013: 5
- FWCI
- 26.97
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Journal of Medical Systems (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Surgery › Healthcare Technology and Patient Monitoring
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Physical Sciences › Computer Science › Computer Networks and Communications › Wireless Sensor Networks for Data Analysis
- Keywords
- patient monitoring, remote patient monitoring, clinical acceptability, system design, system modeling, health care delivery
- MeSH terms
- Confidentiality, Humans, Telemedicine, Monitoring, Ambulatory, Remote Sensing Technology, Wireless Technology
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review