RETRACTED ARTICLE: pH-responsive smart gels of block copolymer [pluronic F127-co-poly(acrylic acid)] for controlled delivery of Ivabradine hydrochloride: its toxicological evaluation
The DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“A comparative review of all results indicates that all the parameters tested for both the control and treated group were very close to each other and within the standard reference range proving that PAG-co-AA hydrogels are nontoxic in nature (Nasir et al., 2019).”
From A novel pH-responsive hydrogel system based on Prunus armeniaca gum and acrylic acid: Preparation and evaluation as a potential candidate for controlled drug delivery. (2023) · cites this paper as Nasir et al., 2019
Citations
Cites
Hydrogel: Preparation, characterization, and applications: A review
Ahmed, E. M. (2015) · Journal of Advanced Research · doi:10.1016/j.jare.2013.07.006 · Cited by 5,800
Higuchi, T. (1963) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.2600521210 · Cited by 4,884
Hydrogels in pharmaceutical formulations
Peppas, N. (2000) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/s0939-6411(00)00090-4 · Cited by 4,011
Analysis of Fickian and non-Fickian drug release from polymers.
Peppas, N. A. (1985) · PubMed · Cited by 2,139
Hydrogels: From controlled release to pH-responsive drug delivery
Gupta, P., Vermani, K., & Garg, S. (2002) · Drug Discovery Today · doi:10.1016/s1359-6446(02)02255-9 · Cited by 1,825 · cited 1×
“Smart gels possess rubbery and soft consistency thus resemble with body tissues [7, 8].”
Polymer microspheres for controlled drug release
Freiberg, S., & Zhu, X. X. (2004) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2004.04.013 · Cited by 1,336
In situ gelling hydrogels for pharmaceutical and biomedical applications
Van Tomme, S. R., Storm, G., & Hennink, W. E. (2008) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2008.01.057 · Cited by 626
Applications of thermo-reversible pluronic F-127 gels in pharmaceutical formulations.
Escobar‐Chávez, J. J., López-Cervantes, M., Naik, A., Kalia, Y. N., Quintanar‐Guerrero, D., & Ganem-Quintanar, A. (2006) · PubMed · Cited by 540
Elliott, J. E., Macdonald, M., Nie, J., & Bowman, C. N. (2004) · Polymer · doi:10.1016/j.polymer.2003.12.040 · Cited by 463 · cited 1×
“Equilibrium swelling of acrylic acid gel affected by ionic strength and pH of solution in which it swells [13].”
BackgroundWang, L., Wang, Z., Zhang, X., Shen, J., Chi, L., & Fuchs, H. (1997) · Macromolecular Rapid Communications · doi:10.1002/marc.1997.030180609 · Cited by 419
Research works printed but not linked: 2
- Sohail M et al (2014) Synthesis and characterization of graft PVA composites for controlled delivery of valsartan. Lat Am J Pharm 33(8):1237–1244
- Swapna G, Srikanth S, Rao UM (2015) Formulation and in-vitro evaluation of Ivabradine buccal tablets. Int J Trends Pharm Life Sci 1(4):457–470
Cited by
Mucoadhesive carriers for oral drug delivery
Kumar, R., Islam, T., & Nurunnabi, M. (2022) · Journal of Controlled Release · doi:10.1016/j.jconrel.2022.09.024 · Cited by 187
Shah, S. A., Sohail, M. F., Khan, S. A., & Kousar, M. (2021) · Materials Science and Engineering C · doi:10.1016/j.msec.2021.112169 · Cited by 127
Shah, S. A., Sohail, M. F., Karperien, M., Johnbosco, C., Mahmood, A., & Kousar, M. (2022) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2022.11.307 · Cited by 81
Shah, S. A., Sohail, M. F., Minhas, M. U., Khan, S., Hussain, Z., Mahmood, A., Kousar, M., Thu, H. E., Abbasi, M., & Kashif, M. U. R. (2021) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2021.06.119 · Cited by 75
Self-citationIjaz, U., Sohail, M. F., Minhas, M. U., Khan, S., Hussain, Z., Kazi, M., Shah, S. A., Mahmood, A., & Maniruzzaman, M. (2022) · Polymers · doi:10.3390/polym14030376 · Cited by 71
Self-citation
Metadata
- Authors
- Nasir, N., Ahmad, M., Minhas, M. U., Barkat, K., & Khalid, M. F.
- Affiliations
- Islamia University of Bahawalpur (PK)
- University of Sargodha (PK)
- University of Lahore (PK)
- Corresponding author
- Ahmad, Mahmood
- Venue
- Journal of Polymer Research
- Published
- 2019-08-10
- Volume
- 26
- Issue
- 9
- ISSN
- 1022-9760 (ISSN-L)
- 1572-8935
- OpenAlex
- W2967291581
- Cited by
- 52
- References
- 48
- Citations by year
- 2026: 3 · 2025: 6 · 2024: 5 · 2023: 8 · 2022: 19 · 2021: 7 · 2020: 4
- FWCI
- 2.60
- Type
- journal article
- Language
- en
- Status
- Retracted
- Update notices
- retraction (2026-05-13)
- Open access
- closed
- Licence
- www.springernature.com/gp/researchers/text-and-data-mining (tdm)
- www.springernature.com/gp/researchers/text-and-data-mining (vor)
- Locations
- Journal of Polymer Research (publishedVersion)
- Topics
- Physical Sciences › Materials Science › Biomaterials › Hydrogels: synthesis, properties, applications
- Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Pharmaceutical Science › Advanced Drug Delivery Systems
- Life Sciences › Agricultural and Biological Sciences › Agronomy and Crop Science › Polymer-Based Agricultural Enhancements
- Keywords
- Pluronic F127, poly(acrylic acid), block copolymers, ivabradine hydrochloride, controlled drug delivery, swelling behavior, drug release kinetics, Higuchi model, Korsmeyer-Peppas model, retracted article
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: RETRACTED ARTICLE: pH-responsive smart gels of block copolymer [pluronic F127-co-poly(acrylic acid)] for controlled delivery of Ivabradine hydrochloride: its toxicological evaluation. https://app.cochat.ai/papers/10.1007/s10965-019-1872-8
- The paper
- Nasir, N., Ahmad, M., Minhas, M. U., Barkat, K., & Khalid, M. F. (2019). RETRACTED ARTICLE: pH-responsive smart gels of block copolymer [pluronic F127-co-poly(acrylic acid)] for controlled delivery of Ivabradine hydrochloride: its toxicological evaluation. Journal of Polymer Research. https://doi.org/10.1007/s10965-019-1872-8
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.