An Activity Recognition System For Mobile Phones
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Training feedforward networks with the Marquardt algorithm
Hagan, M. T., & Menhaj, M. B. (1994) · IEEE Transactions on Neural Networks · doi:10.1109/72.329697 · Cited by 7,701 · cited 1×
“This method is a very accurate learning algorithm [ 8 ], but due to its O(n 2 ) memory and speed requirements it can only be”
MethodActivity Recognition from User-Annotated Acceleration Data
Bao, L., & Intille, S. S. (2004) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-24646-6_1 · Cited by 3,147 · cited 2×
“Bao and Intille conducted an extensive study [ 2 ] with twenty subjects using five wireless biaxial sensors.”
BackgroundActivity recognition from accelerometer data
Ravi, N., Dandekar, N., Mysore, P., & Littman, M. L. (2005) · Innovative Applications of Artificial Intelligence · Cited by 1,818
MIT encyclopedia of cognitive sciences
(1999) · Choice Reviews Online · doi:10.5860/choice.36-4243 · Cited by 1,014
The MIT encyclopedia of the cognitive sciences
(1999) · Choice Reviews Online · doi:10.5860/choice.37-1902 · Cited by 927
Activity Recognition and Monitoring Using Multiple Sensors on Different Body Positions
Maurer, U., Smailagic, A., Siewiorek, D. P., & Deisher, M. (2006) · International Workshop on Wearable and Implantable Body Sensor Networks (BSN'06) · doi:10.1109/bsn.2006.6 · Cited by 601 · cited 1×
“could further enhance the recognition method, as suggested by the experiments in [ 17 ].”
MethodActivity and location recognition using wearable sensors
Lee, S.-W., & Mase, K. (2002) · IEEE Pervasive Computing · doi:10.1109/mprv.2002.1037719 · Cited by 525 · cited 1×
“Lee and Mase [ 14 ] developed an activity and location recognition system using a combination of a biaxial accelerometer, compass, and gyroscope.”
BackgroundMyLifeBits: a personal database for everything
Gemmell, J., Bell, G., & Lueder, R. (2006) · Communications of the ACM · doi:10.1145/1107458.1107460 · Cited by 516 · cited 1×
“Many systems have been developed to collect data from a person’s everyday life for later retrieval (see, e.g., [ 7 , 21]).”
Background"Forget-me-not" Intimate Computing in Support of Human Memory
Lamming, M., & Flynn, M. (1994) · Cited by 416
Recognizing human motion with multiple acceleration sensors
Mantyjarvi, J., Himberg, J., & Seppanen, T. (2002) · 2001 IEEE International Conference on Systems, Man and Cybernetics. e-Systems and e-Man for Cybernetics in Cyberspace (Cat.No.01CH37236) · doi:10.1109/icsmc.2001.973004 · Cited by 323 · cited 1×
“Mantyjarvi et al. [ 16 ] also applied neural networks to human motion recognition.”
BackgroundMulti-sensor Activity Context Detection for Wearable Computing
Kern, N., Schiele, B., & Schmidt, A. (2003) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-39863-9_17 · Cited by 313 · cited 1×
“For human activity recognition, the deployment of multiple accelerometers not only improves the results but is rather mandatory, as noted by Kern et al. [ 10 ].”
MethodContext awareness by analysing accelerometer data
Randell, C., & Muller, H. (2002) · Digest of Papers. Fourth International Symposium on Wearable Computers · doi:10.1109/iswc.2000.888488 · Cited by 243 · cited 1×
“Randell and Muller [ 19 ] used a single biaxial accelerometer to calculate the rms and integrated values over the last two seconds for both axes.”
MethodWearable sensing to annotate meeting recordings
Kern, N., Schiele, B., Junker, H., Lukowicz, P., & Tröster, G. (2003) · Personal and Ubiquitous Computing · doi:10.1007/s00779-003-0242-y · Cited by 89 · cited 1×
“Kern et al. [ 9 ] annotated meeting recordings with motional activities such as standing and sitting to differentiate between presentation and discussion sessions.”
BackgroundRecognizing context for annotating a live life recording
Kern, N., Schiele, B., & Schmidt, A. (2006) · Personal and Ubiquitous Computing · doi:10.1007/s00779-006-0086-3 · Cited by 82 · cited 1×
“Further work [ 11 ] utilizes recognized activity and metainformation from audio for contextual cues in live life recording using a laptop and a wired sensor-based system.”
BackgroundNext-Generation Personal Memory Aids
Vemuri, S. N., & Bender, W. R. (2004) · BT Technology Journal · doi:10.1023/b:bttj.0000047591.29175.89 · Cited by 52 · cited 1×
“Many systems have been developed to collect data from a person’s everyday life for later retrieval (see, e.g., [7, 21 ]).”
Context awareness via a single device-attached accelerometer during mobile computing
Yi, J. S., Choi, Y. S., Jacko, J. A., & Sears, A. (2005) · International Conference on Human-Computer Interaction with Mobile Devices and Services (MobileHCI) · doi:10.1145/1085777.1085839 · Cited by 25 · cited 1×
“Ji Soo Yi et al. [ 22 ] conducted a context awareness study to detect changes in mobility under various lighting conditions using the output of a single tri-axial accelerometer attached to a handheld computer.”
MethodPattern Recognition and Feed-forward Networks
Bishop, C. (2004) · Cited by 13
A scalable mobile phone‐based system for multiple vital signs monitoring and healthcare
Chen, W., Wei, D., Ding, S., Cohen, M., Wang, H., Tokinoya, S., & Takeda, N. (2005) · International Journal of Pervasive Computing and Communications · doi:10.1108/17427370580000121 · Cited by 7 · cited 1×
“Chen et al. [ 4 ] implemented a mobile phone-based system for multiple vital signs monitoring.”
Background
Cited by
Activity recognition using cell phone accelerometers
Kwapisz, J. R., Weiss, G. M., & Moore, S. A. (2011) · ACM SIGKDD Explorations Newsletter · doi:10.1145/1964897.1964918 · Cited by 2,912
Window Size Impact in Human Activity Recognition
Banos, O., Galvez, J.-M., Damas, M., Pomares, H., & Rojas, I. (2014) · Sensors · doi:10.3390/s140406474 · Cited by 648
A Survey on Ambient Intelligence in Healthcare
Acampora, G., Cook, D. J., Rashidi, P., & Vasilakos, A. V. (2013) · Proceedings of the IEEE · doi:10.1109/jproc.2013.2262913 · Cited by 630
Activity recognition on streaming sensor data
Krishnan, N. C., & Cook, D. J. (2014) · Pervasive and Mobile Computing · doi:10.1016/j.pmcj.2012.07.003 · Cited by 488
“More recently researchers are exploring smart phones equipped with accelerometers and gyroscopes to recognize ambulatory movements and gesture patterns [14][15].”
BackgroundA survey on privacy in mobile participatory sensing applications
Christin, D., Reinhardt, A., Kanhere, S. S., & Hollick, M. (2011) · Journal of Systems and Software · doi:10.1016/j.jss.2011.06.073 · Cited by 427
Metadata
- Authors
- Győrbíró, N., Fábián, Á., & Hományi, G.
- Venue
- Mobile Networks and Applications
- Published
- 2008-11-07
- Volume
- 14
- Issue
- 1
- Pages
- 82-91
- ISSN
- 1383-469X (ISSN-L)
- 1572-8153
- OpenAlex
- W2041608059
- Cited by
- 234
- References
- 18
- FWCI
- 15.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.