Taylor Dispersion Analysis Compared to Dynamic Light Scattering for the Size Analysis of Therapeutic Peptides and Proteins and Their Aggregates
Open accessThe DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
PURPOSE: To evaluate Taylor dispersion analysis (TDA) as a novel method for determination of hydrodynamic radius of therapeutic peptides and proteins in non-stressed and stressed formulations and to compare it with dynamic light scattering (DLS). METHODS: The hydrodynamic radius of oxytocin, bovine serum albumin, various monoclonal antibodies (type IgG) and etanercept at concentrations between 0.05 and 50 mg/ml was determined by TDA and DLS. IgGs and etanercept were stressed (elevated temperatures) and analyzed by TDA, DLS and HP-SEC. RESULTS: TDA and DLS were comparable in sizing non-stressed peptides and proteins in a concentration range of about 0.5 to 50 mg/ml. TDA performed well even at lower concentrations, where DLS tends to provide theoretically high values of the Z-average radius. However, because of differences in the detection physics, DLS was more weighted towards the detection of aggregates in stressed formulations than TDA. Advantageously, TDA was also able to size the small peptide oxytocin, which was not feasible by DLS. CONCLUSION: TDA allows the accurate determination of the hydrodynamic radius of peptides and proteins over a wide concentration range, with little interference from excipients present in the sample. It is marginally less sensitive than DLS in detecting size increase for stressed protein samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dispersion of soluble matter in solvent flowing slowly through a tube
Taylor, G. I. (1953) · Proceedings of the Royal Society of London. Series A. Mathematical and Physical Sciences · doi:10.1098/rspa.1953.0139 · Cited by 5,109 · cited 1×
“The method, sometimes termed Taylor-Aris dispersion, was first described by Taylor in 1953 (9) and developed further by Aris in 1956 (10).”
MethodOn the dispersion of a solute in a fluid flowing through a tube
Aris, R. (1956) · Proceedings of the Royal Society of London. Series A. Mathematical and Physical Sciences · doi:10.1098/rspa.1956.0065 · Cited by 2,835
Filipe, V., Hawe, A., & Jiskoot, W. (2010) · Pharmaceutical Research · doi:10.1007/s11095-010-0073-2 · Cited by 1,885 · cited 2×
“coefficient of individual particles by a microscope and camera (8).”
BackgroundMethodSelf-citationProtein aggregation: Pathways, induction factors and analysis
Mahler, H.-C., Friess, W., Grauschopf, U., & Kiese, S. (2009) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.21566 · Cited by 901 · cited 2×
“protein aggregation analysis still lack comparison to more established methods (19).”
MethodResultCarpenter, J. F., Randolph, T. W., Jiskoot, W., Crommelin, D. J. A., Russell Middaugh, C., Winter, G., Fan, Y.-X., Kirshner, S., Verthelyi, D., Kozlowski, S., et al. (2009) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.21530 · Cited by 595
Self-citationWen, J., Arakawa, T., & Philo, J. S. (1996) · Analytical Biochemistry · doi:10.1006/abio.1996.0345 · Cited by 504 · cited 1×
“The combination of HPSEC and FFF with multi-angle laser light scattering detection (4,5) and analytical ultracentrifugation allows for the determination of both the molar mass and size without relying on molecular weight standards.”
MethodLiu, J., Nguyen, M. D. H., Andya, J. D., & Shire, S. J. (2005) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.20347 · Cited by 436 · cited 1×
“The slightly larger radius (7.5–8.3 nm) for the concentrated 50 mg/ml sample can be explained by reversible self-association, which is often observed for monoclonal antibody formulations at high concentrations ( 28 ).”
BackgroundInfluentialJachimska, B., Wasilewska, M., & Adamczyk, Z. (2008) · Langmuir · doi:10.1021/la800548p · Cited by 377 · cited 1×
“DLS resulted in similar results for the hydrodynamic radius of BSA of3.8 to4.3 nm (Fig.1b), which is in good agreement with the theoretical size of 3.3 to 4.3 nm ( 23 ).”
ResultInfluentialMeasuring sub nanometre sizes using dynamic light scattering
Kaszuba, M., McKnight, D., Connah, M. T., McNeil-Watson, F. K., & Nobbmann, U. (2008) · Journal of Nanoparticle Research · doi:10.1007/s11051-007-9317-4 · Cited by 358 · cited 1×
“sucrose, DLS typically measures two peaks corresponding to radii of about 0.5 nm and 100–200 nm ( 29 ).”
BackgroundInfluentialIs any measurement method optimal for all aggregate sizes and types?
Philo, J. S. (2006) · The AAPS Journal · doi:10.1208/aapsj080365 · Cited by 245 · cited 1×
“The hydrodynamic radius is then derived from the diffusion coefficient by the Stokes Einstein equation (2,6,7).”
Method
Cited by
DLS and zeta potential – What they are and what they are not?
Bhattacharjee, S. (2016) · Journal of Controlled Release · doi:10.1016/j.jconrel.2016.06.017 · Cited by 4,702
Nanomedicine in cancer therapy: Challenges, opportunities, and clinical applications
Wicki, A., Witzigmann, D., Balasubramanian, V., & Huwyler, J. (2015) · Journal of Controlled Release · doi:10.1016/j.jconrel.2014.12.030 · Cited by 1,901
Wevers, N. R., Kasi, D. G., Gray, T., Wilschut, K. J., Smith, B., van Vught, R., Shimizu, F., Sano, Y., Kanda, T., Marsh, G., et al. (2018) · Fluids and Barriers of the CNS · doi:10.1186/s12987-018-0108-3 · Cited by 353
Particles in Therapeutic Protein Formulations, Part 1: Overview of Analytical Methods
Zölls, S., Tantipolphan, R., Wiggenhorn, M., Winter, G., Jiskoot, W., Friess, W., & Hawe, A. (2012) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.23001 · Cited by 230
Self-citationAntibody stability: A key to performance - Analysis, influences and improvement
Ma, H., Ó’Fágáin, C., & O’Kennedy, R. (2020) · Biochimie · doi:10.1016/j.biochi.2020.08.019 · Cited by 184
Purifying biopharmaceuticals: knowledge-based chromatographic process development
Hanke, A. T., & Ottens, M. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2014.02.001 · Cited by 176
Filipe, V., Jiskoot, W., Basmeleh, A. H., Halim, A., Schellekens, H., & Brinks, V. (2012) · mAbs · doi:10.4161/mabs.22066 · Cited by 158
Self-citationProteins behaving badly: emerging technologies in profiling biopharmaceutical aggregation
Hamrang, Z., Rattray, N. J. W., & Pluen, A. (2013) · Trends in Biotechnology · doi:10.1016/j.tibtech.2013.05.004 · Cited by 75
Hulse, W. L., Gray, J., & Forbes, R. T. (2013) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2013.05.062 · Cited by 31
Self-citation
Metadata
- Authors
- Hawe, A., Hulse, W. L., Jiskoot, W., & Forbes, R. T.
- Venue
- Pharmaceutical Research
- Published
- 2011-05-11
- Volume
- 28
- Issue
- 9
- Pages
- 2302-2310
- ISSN
- 0724-8741 (ISSN-L)
- 1573-904X
- OpenAlex
- W2083221204
- Cited by
- 221
- References
- 27
- FWCI
- 4.23
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.