Comparing MDI and DPI Aerosol Deposition Using In Vitro Experiments and a New Stochastic Individual Path (SIP) Model of the Conducting Airways
The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Human Respiratory Tract Model for Radiological Protection
Icrp (1994) · Annals of the ICRP · Cited by 1,767
Inhaling medicines: delivering drugs to the body through the lungs
Patton, J. S., & Byron, P. R. (2007) · Nature Reviews Drug Discovery · doi:10.1038/nrd2153 · Cited by 1,331 · cited 1×
“lung and deposition at these sites cannot be predicted based on total lung uptake (70,71).”
BackgroundModels of human lung airways and their application to inhaled particle deposition
Yeh, H.-C., & Schum, G. M. (1980) · Bulletin of Mathematical Biology · doi:10.1007/bf02460796 · Cited by 717
Models of the human bronchial tree.
Horsfield, K., Dart, G., Olson, D. E., Filley, G. F., & Cumming, G. (1971) · Journal of Applied Physiology · doi:10.1152/jappl.1971.31.2.207 · Cited by 685 · cited 1×
“(55), Asgharian and Price (56), and Yin et al.”
BackgroundRespiratory Drug Delivery (1989)
Byron, P. R. (2018) · CRC Press eBooks · doi:10.4324/9780203710456 · Cited by 449
Inhaled Corticosteroids for Asthma Therapy
Cochrane, M. G., Bala, M. V., Downs, K. E., Mauskopf, J., & Ben-Joseph, R. H. (2000) · Chest · doi:10.1378/chest.117.2.542 · Cited by 428
Particle Deposition in a Multiple-Path Model of the Human Lung
Asgharian, B., Hofmann, W., & Bergmann, R. (2001) · Aerosol Science and Technology · doi:10.1080/02786820119122 · Cited by 408
Evolution of dry powder inhaler design, formulation, and performance
NEWMAN, S. P., & BUSSE, W. W. (2002) · Respiratory Medicine · doi:10.1053/rmed.2001.1276 · Cited by 340 · cited 6×
“This is one factor in the increasing development and use of DPIs (4,6).”
BackgroundResultInfluentialImproved numerical simulation of aerosol deposition in an idealized mouth–throat
Matida, E. A., Finlay, W. H., Lange, C. F., & Grgic, B. (2004) · Journal of Aerosol Science · doi:10.1016/s0021-8502(03)00381-1 · Cited by 293 · cited 1×
“Previous studies have shown that the isotropic turbulence approximation, which is assumed with the LRN k-ω model, can over predict aerosol deposition (64).”
BackgroundTransport and Deposition of Micro-Aerosols in Realistic and Simplified Models of the Oral Airway
Xi, J., & Longest, P. W. (2007) · Annals of Biomedical Engineering · doi:10.1007/s10439-006-9245-y · Cited by 275 · cited 5×
“The inhalers are connected to a characteristic MT geometry based on the elliptical model originally proposed by Xi and Longest (43).”
MethodInfluentialSelf-citation
Cited by
In silico clinical trials: how computer simulation will transform the biomedical industry
Viceconti, M., Henney, A., & Morley-Fletcher, E. (2016) · International Journal of Clinical Trials · doi:10.18203/2349-3259.ijct20161408 · Cited by 289
Metadata
- Authors
- Longest, P. W., Tian, G., Walenga, R. L., & Hindle, M.
- Venue
- Pharmaceutical Research
- Published
- 2012-01-31
- Volume
- 29
- Issue
- 6
- Pages
- 1670-1688
- ISSN
- 0724-8741 (ISSN-L)
- 1573-904X
- OpenAlex
- W2078671329
- Cited by
- 182
- References
- 46
- FWCI
- 8.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparing MDI and DPI Aerosol Deposition Using In Vitro Experiments and a New Stochastic Individual Path (SIP) Model of the Conducting Airways. https://app.cochat.ai/papers/10.1007/s11095-012-0691-y
- The paper
- Longest, P. W., Tian, G., Walenga, R. L., & Hindle, M. (2012). Comparing MDI and DPI Aerosol Deposition Using In Vitro Experiments and a New Stochastic Individual Path (SIP) Model of the Conducting Airways. Pharmaceutical Research. https://doi.org/10.1007/s11095-012-0691-y
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.