Routine coagulation tests in newborn and young infants
Abstract
Background The diagnostic approach to haemostatic defects in the newborn is challenging and requires appropriate interpretation of coagulation tests according to reference values dependent on the postnatal age.Methods This investigation was designed to study the postnatal development of the human coagulation system in newborn infants and to develop appropriate reference ranges for prothrombin time (PT), activated partial thromboplastin time (APTT) and fibrinogen (FBG) according at the day of birth and for the following postnatal period (days 1, 2, 3, 4, 5, 6, from 7 to 10 and from 11 to 44).Results The mean FBG value was already within the adult reference range in newborns at birth, the mean PT value fell within the adult reference range in infants aged 4 days or more, whereas the mean APTT value was still higher than the upper limit of the adult reference range in infants aged between 11 and 20 days. The prevalence of infants with pathological values according to the actual adult reference ranges was limited for FBG (from 24 to 7%), decreased from 92 to 8% in infants aged 0 and 11-20 days for PT, but remained elevated throughout the observational period for APTT (from 94 to 71%).Conclusions The results of the present investigation demonstrate that the actual adult reference ranges for coagulation screening tests, especially PT and APTT, cannot be applied to newborns and young infants.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Excess thyroid hormone activity results in a procoagulant state, with increased VWF, FVIII, fibrinogen, and D-dimer in subclinical hyperthyroidism and elevations in fibrinogen, fibronectin, VWF, thrombomodulin, and PAI-1, with decreased t-PA in overt endogenous hyperthyroidism.
“Excess thyroid hormone activity results in a procoagulant state, with increased VWF, FVIII, fibrinogen, and D-dimer in subclinical hyperthyroidism and elevations in fibrinogen, fibronectin, VWF, thrombomodulin, and PAI-1, with decreased t-PA in overt, endogenous hyperthyroidism”
From Pharmacodynamic and Therapeutic Actions of Levothyroxine (2021) · cites this paper as [112]
Cites
Development of the human coagulation system in the full-term infant
Andrew, M., Paes, B. A., MILNER, R. A., et al. (1987) · Blood · doi:10.1182/blood.v70.1.165.165 · Cited by 1,187 · see citing works
Maturation of the hemostatic system during childhood
Andrew, M., Vegh, P., Johnston, M., Bowker, J., Ofosu, F. A., & Mitchell, L. (1992) · Blood · doi:10.1182/blood.v80.8.1998.1998 · Cited by 923 · see citing works
Development of the human coagulation system in the healthy premature infant
Andrew, M., Paes, B. A., MILNER, R. A., et al. (1988) · Blood · doi:10.1182/blood.v72.5.1651.1651 · Cited by 737 · see citing works
Development of the Hemostatic System in the Neonate and Young Infant
Andrew, M. E., Paes, B. A., & Johnston, M. (1990) · Journal of Pediatric Hematology/Oncology · doi:10.1097/00043426-199021000-00019 · Cited by 532 · see citing works
Phlebotomy in the intensive care unit: strategies for blood conservation.
Barie, P. S. (2004) · Critical Care · doi:10.1186/cc2454 · Cited by 265 · see citing works
Coagulation Studies in Extremely Premature Infants
Barnard, D., Simmons, M. A., & Hathaway, W. E. (1979) · Pediatric Research · doi:10.1203/00006450-197912000-00006 · Cited by 76 · see citing works
Coagulation Studies in Very Low-Birthweight Infants
Seguin, J., & Topper, W. H. (1994) · American Journal of Perinatology · doi:10.1055/s-2007-994529 · Cited by 17 · see citing works
Coagulation profile in healthy Nigerian neonates.
Okunade, M. A., & Essien, E. M. (1999) · PubMed · Cited by 6 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Pharmacodynamic and Therapeutic Actions of Levothyroxine
Hennessey, J. V. (2021) · 70 Years of Levothyroxine · doi:10.1007/978-3-030-63277-9_3 · Cited by 4 · see citing works
- Authors
- Lippi, G., Salvagno, G. L., Rugolotto, S., Chiaffoni, G. P., Padovani, E. M., Franchini, M., & Guidi, G. C.
- Affiliations
- University of Verona (IT)
- Azienda Ospedaliera Universitaria Integrata Verona (IT)
- Corresponding author
- Lippi, Giuseppe
- Venue
- Journal of Thrombosis and Thrombolysis
- Published
- 2007-05-18
- Volume
- 24
- Issue
- 2
- Pages
- 153-155
- ISSN
- 0929-5305 (ISSN-L)
- 1573-742X
- OpenAlex
- W1982177271
- Cited by
- 28
- References
- 8
- Citations by year
- 2026: 1 · 2024: 1 · 2023: 1 · 2022: 2 · 2021: 2 · 2019: 2 · 2018: 2 · 2017: 1 · 2016: 1 · 2015: 3 · 2012: 1
- FWCI
- 2.13
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Journal of Thrombosis and Thrombolysis (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Hematology › Blood Coagulation and Thrombosis Mechanisms
- Health Sciences › Medicine › Physiology › Clinical Laboratory Practices and Quality Control
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Blood properties and coagulation
- Keywords
- neonates, infants, coagulation tests, prothrombin time, activated partial thromboplastin time, fibrinogen, reference values, coagulation screening
- MeSH terms
- Adult, Blood Coagulation, Blood Coagulation Tests, Fibrinogen, Humans, Infant, Infant, Newborn, Mass Screening, Partial Thromboplastin Time, Prothrombin Time, Reference Values
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review