Effects of sample handling and storage on quantitative lipid analysis in human serum
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
There is sparse information about specific storage and handling protocols that minimize analytical error and variability in samples evaluated by targeted metabolomics. Variance components that affect quantitative lipid analysis in a set of human serum samples were determined. The effects of freeze-thaw, extraction state, storage temperature, and freeze-thaw prior to density-based lipoprotein fractionation were quantified. The quantification of high abundance metabolites, representing the biologically relevant lipid species in humans, was highly repeatable (with coefficients of variation as low as 0.01 and 0.02) and largely unaffected by 1-3 freeze-thaw cycles (with 0-8% of metabolites affected in each lipid class). Extraction state had effects on total lipid class amounts, including decreased diacylglycerol and increased phosphatidylethanolamine in thawed compared with frozen samples. The effects of storage temperature over 1 week were minimal, with 0-4% of metabolites affected by storage at 4 degrees C, -20 degrees C, or -80 degrees C in most lipid classes, and 19% of metabolites in diacylglycerol affected by storage at -20 degrees C. Freezing prior to lipoprotein fractionation by density ultracentrifugation decreased HDL free cholesterol by 37% and VLDL free fatty acid by 36%, and increased LDL cholesterol ester by 35% compared with fresh samples. These findings suggest that density-based fractionation should preferably be undertaken in fresh serum samples because up to 37% variability in HDL and LDL cholesterol could result from a single freeze-thaw cycle. Conversely, quantitative lipid analysis within unfractionated serum is minimally affected even with repeated freeze-thaw cycles.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zivkovic, A. M., Wiest, M. M., Nguyen, U., Nording, M. L., Watkins, S. M., & German, J. B. (2009) · Metabolomics · doi:10.1007/s11306-008-0136-0 · Cited by 63 · cited 1×
“biological variability among individuals, which is a topic of great interest in the clinical research community, and which has been studied previously (Ruhli et al. 2008; Zivkovic et al. 2008 ).”
BackgroundSelf-citation
Cited by
Zhou, B., Xiao, J. F., Tuli, L., & Ressom, H. W. (2011) · Molecular BioSystems · doi:10.1039/c1mb05350g · Cited by 639
Kuehnbaum, N. L., & Britz-McKibbin, P. (2013) · Chemical Reviews · doi:10.1021/cr300484s · Cited by 354
Quality assurance procedures for mass spectrometry untargeted metabolomics. a review
Dudzik, D., Barbas-Bernardos, C., García, A., & Barbas, C. (2018) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2017.07.044 · Cited by 344
Burla, B., Arita, M., Arita, M., Bendt, A. K., Cazenave-Gassiot, A., Dennis, E. A., Ekroos, K., Han, X., Ikeda, K., Liebisch, G., et al. (2018) · Journal of Lipid Research · doi:10.1194/jlr.s087163 · Cited by 312
Sarafian, M. H., Gaudin, M., Lewis, M. R., Martin, F.-P., Holmes, E., Nicholson, J. K., & Dumas, M.-E. (2014) · Analytical Chemistry · doi:10.1021/ac500317c · Cited by 301
Metadata
- Authors
- Zivkovic, A. M., Wiest, M. M., Nguyen, U. T., Davis, R., Watkins, S. M., & German, J. B.
- Venue
- Metabolomics
- Published
- 2009-08-05
- Volume
- 5
- Issue
- 4
- Pages
- 507-516
- ISSN
- 1573-3882 (ISSN-L)
- 1573-3890
- OpenAlex
- W2105537689
- Cited by
- 154
- References
- 1
- FWCI
- 2.04
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effects of sample handling and storage on quantitative lipid analysis in human serum. https://app.cochat.ai/papers/10.1007/s11306-009-0174-2
- The paper
- Zivkovic, A. M., Wiest, M. M., Nguyen, U. T., Davis, R., Watkins, S. M., & German, J. B. (2009). Effects of sample handling and storage on quantitative lipid analysis in human serum. Metabolomics. https://doi.org/10.1007/s11306-009-0174-2
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.