Auto bi-level pressure relief–PAP is as effective as CPAP in OSA patients—a pilot study
The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
Purpose Continuous positive airway pressure (CPAP) is the therapy of choice for the treatment of obstructive sleep apnea (OSA). Not all patients can use CPAP therapy with adequate compliance. There is a need to develop more comfortable modes. Auto bi-level Pressure Relief-Positive Airway Pressure (ABPR-PAP) can be an alternative. We conducted a prospective double-blind, randomised trial to evaluate the efficacy and compliance of ABPR-PAP compared with CPAP in OSA patients. Methods We included 35 CPAP naive patients (age 53.3 ± 10.3 years, BMI 31.0 ± 5.0 kg/m(2), ESS 10.0 ± 4.2) diagnosed with moderate to severe OSA who underwent a successful CPAP titration. Patients were randomised into the CPAP or the ABPR-PAP treatment group. We used the same device (BIPAP® Auto, Philips Respironics) for CPAP or ABPR-PAP. Apnea-hypopnea index (AHI) was determined using polysomnography before (AHI 40.6 ± 18.3 per hour) and after treatment. Results Eighteen patients received CPAP and the remaining 17 received APBR-PAP. Groups were similar in terms of demographics and OSA severity. There were no serious adverse events during the trial. CPAP was fixed by a sleep expert and ABPR-PAP varied (range 5-15 cmH(2)O). AHI decreased in the CPAP group to 6.4 ± 5.7 per hour and in the ABPR-PAP group to 4.8 ± 3.6 per hour in the first night (N = 35). After 3 months, the AHI decreased in the CPAP group to 4.4 ± 5.3 per hour and in the ABPR-PAP group to 2.6 ± 3.8 per hour (N = 32). Differences between the gr…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In addition, in one other available study, 213 there was no difference between BPAP and CPAP treatment in sleep quality as assessed by the Pittsburgh Sleep Quality Index”
In the citing paper
“Metaanalysis of the 2 RCTs 210,213 did not demonstrate a clinically significant difference in residual AHI with treatment using BPAP compared to CPAP”
Citations
Cites
The Pittsburgh Sleep Quality Index: a new instrument for psychiatric practice and research
Buysse, D. J., Reynolds, C. F., Monk, T. H., Berman, S. R., & Kupfer, D. J. (1989) · Psychiatry Research · doi:10.1016/0165-1781(89)90047-4 · Cited by 35,234 · cited 1×
“The PSQI showed adequate reliability and good validity [15].”
BackgroundMcNicholas, W. T., Strohl, K. P., White, D. P., Levy, P. A., Schmidt, W., Wheatley, J. R., Redline, S. S., Carley, D. W., Buysse, D. J., Young, T. B., et al. (1999) · PubMed · Cited by 3,665
EEG Arousals: Scoring Rules and Examples
(1992) · Sleep · doi:10.1093/sleep/15.2.173 · Cited by 1,637
Objective Measurement of Patterns of Nasal CPAP Use by Patients with Obstructive Sleep Apnea
Kribbs, N. B., Pack, A. I., Kline, L. R., Smith, P. L., Schwartz, A. R., Schubert, N. M., Redline, S., Henry, J. N., Getsy, J. E., & Dinges, D. F. (1993) · American Review of Respiratory Disease · doi:10.1164/ajrccm/147.4.887 · Cited by 1,339 · cited 1×
“Despite the proven value of CPAP, compliance has been reported to be low [3, 4].”
BackgroundContinuous positive airways pressure for obstructive sleep apnoea in adults
Giles, T., Lasserson, T., Smith, B., White, J., Wright, J., & Cates, C. (2006) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd001106.pub2 · Cited by 1,001
Kushida, C. A., Littner, M. R., Hirshkowitz, M., Morgenthaler, T. I., Alessi, C. A., Bailey, D., Boehlecke, B., Brown, T. M., Coleman, J., Friedman, L., et al. (2006) · Sleep · doi:10.1093/sleep/29.3.375 · Cited by 775
Night-To-Night Variability in CPAP Use Over the First Three Months of Treatment
Weaver, T. E., Kribbs, N. B., Pack, A. I., Kline, L. R., Chugh, D. K., Maislin, G., Smith, P. L., Schwartz, A. R., Schubert, N. M., Gillen, K. A., et al. (1997) · Sleep · doi:10.1093/sleep/20.4.278 · Cited by 530 · cited 1×
“The 90-day follow-up may have been insufficient to determine longterm compliance benefits, however, in line with the data from other studies [23, 24].”
ResultMortality in Obstructive Sleep Apnea-Hypopnea Patients Treated With Positive Airway Pressure
Campos-Rodriguez, F., Peña-Griñan, N., Reyes-Nuñez, N., De la Cruz-Moron, I., Perez-Ronchel, J., De la Vega-Gallardo, F., & Fernandez-Palacin, A. (2005) · Chest · doi:10.1378/chest.128.2.624 · Cited by 408
Cited by
Patil, S. P., Ayappa, I. A., Caples, S. M., Kimoff, R. J., Patel, S. R., & Harrod, C. G. (2019) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.7638 · Cited by 721
“,213 One study employed the”
InfluentialIntegrating psychology and medicine in CPAP adherence – New concepts?
Crawford, M., Espie, C. A., Bartlett, D. J., & Grunstein, R. R. (2013) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2013.03.002 · Cited by 120
A multicenter evaluation of oral pressure therapy for the treatment of obstructive sleep apnea
Colrain, I. M., Black, J. E., Siegel, L. C., Bogan, R., Becker, P. M., Farid-Moayer, M., Goldberg, R., Lankford, D. A., Goldberg, A. N., & Malhotra, A. (2013) · Sleep Medicine · doi:10.1016/j.sleep.2013.05.009 · Cited by 84
Sharples, L., Glover, M., Clutterbuck-James, A., Bennett, M., Jordan, J., Chadwick, R., Pittman, M., East, C., Cameron, M., Davies, M., et al. (2014) · Health Technology Assessment · doi:10.3310/hta18670 · Cited by 63
Kennedy, B., Lasserson, T. J., Wozniak, D. R., & Smith, I. (2019) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd003531.pub4 · Cited by 47
Carlucci, A., Ceriana, P., Mancini, M., Cirio, S., Pierucci, P., Lupo, N. D., Gadaleta, F., Morrone, E., & Fanfulla, F. (2015) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.5008 · Cited by 46
Mohamed, B. A., Yarlagadda, K., Self, Z., Simon, A., Rigueiro, F., Sohooli, M., Eisenschenk, S. J., & Doré, S. (2023) · Translational Stroke Research · doi:10.1007/s12975-023-01123-x · Cited by 34
The intersection of obstructive lung disease and sleep apnea
Khatri, S. B., & Ioachimescu, O. C. (2016) · Cleveland Clinic Journal of Medicine · doi:10.3949/ccjm.83a.14104 · Cited by 33
Hoshino, T., Sasanabe, R., Tanigawa, T., Murotani, K., Arimoto, M., Ueda, H. H., & Shiomi, T. (2018) · Journal of International Medical Research · doi:10.1177/0300060518758583 · Cited by 29
Ishak, A., Ramsay, M., Hart, N., & Steier, J. S. (2019) · Respirology · doi:10.1111/resp.13674 · Cited by 33
“(22-25) Furthermore, standard BPAP was only used in one study included.”
BackgroundMethodZhu, K., Aouf, S., Roisman, G. L., & Escourrou, P. (2016) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.5590 · Cited by 25
Bilevel positive airway pressure for obstructive sleep apnea
Mansukhani, M. P., Kolla, B. P., Olson, E. J., Ramar, K., & Morgenthaler, T. I. (2014) · Expert Review of Medical Devices · doi:10.1586/17434440.2014.900435 · Cited by 24
Improvements in current treatments and emerging therapies for adult obstructive sleep apnea
Freedman, N. S. (2014) · F1000Prime Reports · doi:10.12703/p6-36 · Cited by 21
Álvarez, D., Gutiérrez‐Tobal, G. C., del Campo, F., & Hornero, R. (2015) · Expert Opinion on Therapeutic Patents · doi:10.1517/13543776.2015.1054094 · Cited by 14
“Although these technologies have been shown to be safe and effective, no compliance or clinical benefits have been demonstrated [16].”
BackgroundUse of autobilevel ventilation in patients with obstructive sleep apnea: An observational study
Baiamonte, P., Mazzuca, E., Gruttad’Auria, C. I., Castrogiovanni, A., Mariño, C., Nardo, D. L., Basile, M., Algeri, M., Battaglia, S. L., Marrone, O., et al. (2018) · Journal of Sleep Research · doi:10.1111/jsr.12680 · Cited by 12
“Adherence to AutoBi therapy was reported to be similar (Blau et al., 2012; Powell, Gay, Ojile, Litinski, & Malhotra, 2012) or better than to CPAP in patients with OSA (Ballard, Gay, & Strollo, 2007; Gentina et al.”
MethodHuang, X., Saha, G., Paul, A. R., Tahan, A., & Saha, S. C. (2025) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2025.104397 · Cited by 9
“…under various conditions: IPAP/EPAP settings of 12/8 cmH 2 O typically recommended for CSA and OSA (American Academy of Sleep Medicine et al., 2008; Blau et al., 2012); 16/6 cmH 2 O for COPD (Bhatt et al., 2013; Paone et al., 2014; Funk et al., 2011); and 18/8 cmH 2 O for OHS (Borel et al., 2012;…”
Hoshino, T., Sasanabe, R., Murotani, K., Arimoto, M., Inagawa, S., Tanigawa, T., Uchida, Y., Ogawa, T., Ueda, H. H., & Shiomi, T. (2016) · PubMed Central · doi:10.18999/nagjms.78.2.195 · Cited by 10
Raj, A., Bansal, S., Dhooria, S., Jain, D., Virk, R. S., & Panda, N. K. (2023) · Sleep And Breathing · doi:10.1007/s11325-023-02787-3 · Cited by 8
“In their study [14] comparing ABPR-PAP and CPAP, Blau et al. came to the conclusion that ABPR-PAP can be utilized as an appropriate substitute for CPAP.”
MethodWatanabe, N., Levri, J. M., Peng, V. T., Scharf, S. M., & Diaz‐Abad, M. (2022) · Sleep Science · doi:10.5935/1984-0063.20210015 · Cited by 4
HAKIM, T. S. (2015) · Journal of Lung Pulmonary & Respiratory Research · doi:10.15406/jlprr.2015.02.00065 · Cited by 4
“Indeed, most studies have shown that there is little difference between BiPAP and CPAP therapy, as far as benefits, comfort, and compliance [3,7-11].”
BackgroundObstructive Sleep Apnea and Modifications in Sedation
Weatherspoon, D. L., Sullivan, D., & Weatherspoon, C. A. (2016) · Critical Care Nursing Clinics of North America · doi:10.1016/j.cnc.2016.02.008 · Cited by 3
Advanced Positive Airway Pressure Modalities
Bierer, G. B., Ryden, A., & Aysola, R. (2015) · Current Sleep Medicine Reports · doi:10.1007/s40675-015-0031-y · Cited by 3
“Though multiple manufacturers offer BPAP devices, there has not been convincing evidence that BPAP improves adherence or outcomes when compared to CPAP [22, 67].”
BackgroundAssefa, S. Z., Diaz‐Abad, M., & Scharf, S. M. (2017) · InTech eBooks · doi:10.5772/66816 · Cited by 2
Vats, M. G. (2017) · InTech eBooks · doi:10.5772/62967 · Cited by 2
Simonelli, C., Vitacca, M., Salvi, B., Saleri, M., & Paneroni, M. (2023) · Monaldi Archives for Chest Disease · doi:10.4081/monaldi.2023.2673 · Cited by 2
“Continuous positive airway pressure (CPAP) is the first-line treatment for OSAS, as its positive effects on symptoms and respiratory and cardiovascular risks have been widely demonstrated [3-5].”
BackgroundMessineo, L., Bakker, J. P., Noah, W. H., & White, D. P. (2026) · EClinicalMedicine · doi:10.1016/j.eclinm.2026.103993 · Cited by 1
Modalities and Indications of Positive Airway Pressure in Sleep Apnea
Mun, S. J., & Cho, K. (2019) · Journal of Clinical Otolaryngology Head and Neck Surgery · doi:10.35420/jcohns.2019.30.1.25 · Cited by 1
Use of nNIV in Obstructive Sleep Apnea: Modes, Flexes, and More
Weingarten, J. A. (2015) · Springer eBooks · doi:10.1007/978-1-4899-7624-6_9 · Cited by 1
“In the only trial of auto-BPAP versus standard CPAP in patients with moderate to severe OSA requiring PAP for the first time, 35 patients were randomized and evaluated after using their respective device after 12 weeks [45].”
MethodContinuous Positive Airway Pressure Use and Mild Obstructive Sleep Apnea Syndrome (OSAS)
Nelson, M. (2014) · UWM Digital Commons (University of Wisconsin–Milwaukee) · Cited by 1
José Luis Carrillo, A., Salazar-Peña, C. M., Martha Guadalupe Torres, F., María Del Rocío Baños, F., & Luis Torre, B. (2018) · Revista chilena de enfermedades respiratorias · doi:10.4067/s0717-73482018000200089
BiPAP for OSA, OHS Overlap Syndrome and Nocturnal Enuresis: A Case Report
朱, 祥. (2024) · Journal of Clinical Personalized Medicine · doi:10.12677/jcpm.2024.31012
Évaluation sur banc d'essai des algorithmes des machines ventilatoires
Zhu, K. (2016) · theses.fr (ABES) · doi:10.70675/cc931d14zf343z4f06zb4e6za20fa6182322 · Cited by 3
Fietze, I., Dillmann, S., Salanitro, M., Toncar, T., Glos, M., Rosenblum, L., & Penzel, T. (2026) · Sleep Medicine · doi:10.1016/j.sleep.2026.109137
Self-citation
Metadata
- Authors
- Blau, A., Minx, M., Peter, J. G., Glos, M., Penzel, T., Baumann, G., & Fietze, I.
- Affiliations
- Charité – Universitätsmedizin Berlin (DE)
- Corresponding author
- Blau, Alexander
- Venue
- Sleep and Breathing
- Published
- 2011-08-27
- Volume
- 16
- Issue
- 3
- Pages
- 773-779
- ISSN
- 1520-9512 (ISSN-L)
- 1522-1709
- OpenAlex
- W2025135842
- Semantic Scholar
- 603893d50e8ed3160333ffd7655423c4ad637102
- Cited by
- 32
- References
- 26
- Citations by year
- 2026: 2 · 2025: 1 · 2024: 1 · 2023: 3 · 2022: 1 · 2019: 4 · 2018: 3 · 2017: 2 · 2016: 4 · 2015: 5 · 2014: 4 · 2013: 2
- FWCI
- 1.31
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Sleep And Breathing (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Respiratory Support and Mechanisms
- Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
- Keywords
- obstructive sleep apnea, continuous positive airway pressure, CPAP adherence, apnea-hypopnea index, CPAP titration
- MeSH terms
- Adult, Aged, Double-Blind Method, Equipment Design, Female, Humans, Male, Middle Aged, Patient Compliance, Pilot Projects, Prospective Studies, Sleep Stages, Therapy, Computer-Assisted, Polysomnography, Sleep Apnea, Obstructive, Continuous Positive Airway Pressure
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.