Auto bi-level pressure relief–PAP is as effective as CPAP in OSA patients—a pilot study
The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
Purpose Continuous positive airway pressure (CPAP) is the therapy of choice for the treatment of obstructive sleep apnea (OSA). Not all patients can use CPAP therapy with adequate compliance. There is a need to develop more comfortable modes. Auto bi-level Pressure Relief-Positive Airway Pressure (ABPR-PAP) can be an alternative. We conducted a prospective double-blind, randomised trial to evaluate the efficacy and compliance of ABPR-PAP compared with CPAP in OSA patients. Methods We included 35 CPAP naive patients (age 53.3 ± 10.3 years, BMI 31.0 ± 5.0 kg/m(2), ESS 10.0 ± 4.2) diagnosed with moderate to severe OSA who underwent a successful CPAP titration. Patients were randomised into the CPAP or the ABPR-PAP treatment group. We used the same device (BIPAP® Auto, Philips Respironics) for CPAP or ABPR-PAP. Apnea-hypopnea index (AHI) was determined using polysomnography before (AHI 40.6 ± 18.3 per hour) and after treatment. Results Eighteen patients received CPAP and the remaining 17 received APBR-PAP. Groups were similar in terms of demographics and OSA severity. There were no serious adverse events during the trial. CPAP was fixed by a sleep expert and ABPR-PAP varied (range 5-15 cmH(2)O). AHI decreased in the CPAP group to 6.4 ± 5.7 per hour and in the ABPR-PAP group to 4.8 ± 3.6 per hour in the first night (N = 35). After 3 months, the AHI decreased in the CPAP group to 4.4 ± 5.3 per hour and in the ABPR-PAP group to 2.6 ± 3.8 per hour (N = 32). Differences between the gr…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In addition, in one other available study, 213 there was no difference between BPAP and CPAP treatment in sleep quality as assessed by the Pittsburgh Sleep Quality Index”
In the citing paper
“Metaanalysis of the 2 RCTs 210,213 did not demonstrate a clinically significant difference in residual AHI with treatment using BPAP compared to CPAP”
Citations
Cites
The Pittsburgh Sleep Quality Index: a new instrument for psychiatric practice and research
Buysse, D. J., Reynolds, C. F., Monk, T. H., Berman, S. R., & Kupfer, D. J. (1989) · Psychiatry Research · doi:10.1016/0165-1781(89)90047-4 · Cited by 35,234 · cited 1×
“The PSQI showed adequate reliability and good validity [15].”
BackgroundMcNicholas, W. T., Strohl, K. P., White, D. P., Levy, P. A., Schmidt, W., Wheatley, J. R., Redline, S. S., Carley, D. W., Buysse, D. J., Young, T. B., et al. (1999) · PubMed · Cited by 3,665
EEG Arousals: Scoring Rules and Examples
(1992) · Sleep · doi:10.1093/sleep/15.2.173 · Cited by 1,637
Objective Measurement of Patterns of Nasal CPAP Use by Patients with Obstructive Sleep Apnea
Kribbs, N. B., Pack, A. I., Kline, L. R., Smith, P. L., Schwartz, A. R., Schubert, N. M., Redline, S., Henry, J. N., Getsy, J. E., & Dinges, D. F. (1993) · American Review of Respiratory Disease · doi:10.1164/ajrccm/147.4.887 · Cited by 1,339 · cited 1×
“Despite the proven value of CPAP, compliance has been reported to be low [3, 4].”
BackgroundContinuous positive airways pressure for obstructive sleep apnoea in adults
Giles, T., Lasserson, T., Smith, B., White, J., Wright, J., & Cates, C. (2006) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd001106.pub2 · Cited by 1,001
Kushida, C. A., Littner, M. R., Hirshkowitz, M., Morgenthaler, T. I., Alessi, C. A., Bailey, D., Boehlecke, B., Brown, T. M., Coleman, J., Friedman, L., et al. (2006) · Sleep · doi:10.1093/sleep/29.3.375 · Cited by 775
Night-To-Night Variability in CPAP Use Over the First Three Months of Treatment
Weaver, T. E., Kribbs, N. B., Pack, A. I., Kline, L. R., Chugh, D. K., Maislin, G., Smith, P. L., Schwartz, A. R., Schubert, N. M., Gillen, K. A., et al. (1997) · Sleep · doi:10.1093/sleep/20.4.278 · Cited by 530 · cited 1×
“The 90-day follow-up may have been insufficient to determine longterm compliance benefits, however, in line with the data from other studies [23, 24].”
ResultMortality in Obstructive Sleep Apnea-Hypopnea Patients Treated With Positive Airway Pressure
Campos-Rodriguez, F., Peña-Griñan, N., Reyes-Nuñez, N., De la Cruz-Moron, I., Perez-Ronchel, J., De la Vega-Gallardo, F., & Fernandez-Palacin, A. (2005) · Chest · doi:10.1378/chest.128.2.624 · Cited by 408
Nasal CPAP: an objective evaluation of patient compliance.
Reeves-Hoche, M. K., Meck, R., & Zwillich, C. W. (1994) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.149.1.8111574 · Cited by 357 · cited 1×
“Despite the proven value of CPAP, compliance has been reported to be low [3, 4].”
BackgroundPiper, A. J., Wang, D., Yee, B. J., Barnes, D. J., & Grunstein, R. R. (2008) · Thorax · doi:10.1136/thx.2007.081315 · Cited by 323
Ayas, N. T., Patel, S. R., Malhotra, A., Schulzer, M., Malhotra, M., Jung, D., Fleetham, J., & White, D. P. (2004) · Sleep · doi:10.1093/sleep/27.2.249 · Cited by 255 · cited 2×
“Although these technologies have been shown to be safe and effective, no compliance or clinical benefits have been demonstrated in CPAP-naive patients [5–7].”
BackgroundDanker‐Hopfe, H., Kunz, D., Gruber, G., Klösch, G., Lorenzo, J. L., Himanen, S. L., Kemp, B., Penzel, T., Röschke, J., Dorn, H., et al. (2004) · Journal of Sleep Research · doi:10.1046/j.1365-2869.2003.00375.x · Cited by 217 · cited 1×
“Sleep stages were scored according to Rechtschaffen and Kales by two experts to minimize intrascorer variability [12].”
MethodSelf-citationTreatment Adherence and Outcomes in Flexible vs Standard Continuous Positive Airway Pressure Therapy
Aloia, M. S., Stanchina, M. L., Arnedt, J. T., Malhotra, A., & Millman, R. P. (2005) · CHEST Journal · doi:10.1378/chest.127.6.2085 · Cited by 162 · cited 1×
“7 h greater use per night [21]; however, this was not a randomised study as patients received the mode of therapy that was available at the time of therapy allocation.”
BackgroundHow Early in Treatment is PAP Adherence Established? Revisiting Night-to-Night Variability
Aloia, M. S., Arnedt, J. T., Stanchina, M., & Millman, R. P. (2007) · Behavioral Sleep Medicine · doi:10.1080/15402000701264005 · Cited by 125
JANSON, C., NÖGES, E., SVEDBERG-BRANDT, S., & LINDBERG, E. (2000) · Respiratory Medicine · doi:10.1053/rmed.1999.0703 · Cited by 121 · cited 1×
“Complaints of nasal and pharyngeal symptoms and lack of subjective perceived benefit from treatment tend to represent more common reasons for non-compliance [20].”
BackgroundPressure-Relief Continuous Positive Airway Pressure vs Constant Continuous Positive Airway Pressure
Nilius, G., Happel, A., Domanski, U., & Ruhle, K.-H. (2006) · Chest · doi:10.1378/chest.130.4.1018 · Cited by 99 · cited 2×
“Although these technologies have been shown to be safe and effective, no compliance or clinical benefits have been demonstrated in CPAP-naive patients [5–7].”
BackgroundFietze, I., Blau, A., Glos, M., Theres, H., Baumann, G., & Penzel, T. (2007) · Sleep Medicine · doi:10.1016/j.sleep.2007.09.008 · Cited by 98
Self-citationGay, P. C., Herold, D. L., & Olson, E. J. (2003) · Sleep · doi:10.1093/sleep/26.7.864 · Cited by 90 · cited 1×
“The residual AHI on ABPR-PAP is also similar to that reported on APAP [17, 18] and a Bi-Flex® precursor in a traditional bi-level device [19].”
ResultKushida, C. A., Nichols, D. A., Quan, S. F., Goodwin, J. L., White, D. P., Gottlieb, D. J., Walsh, J. K., Schweitzer, P. K., Guilleminault, C., Simon, R., et al. (2006) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.26588 · Cited by 80 · cited 1×
“CPAP eliminates nocturnal breathing difficulties, enhances sleep quality, reduces self-reported sleepiness, improves quality of life and reduces cardiovascular risk [1, 2].”
BackgroundBakker, J., Campbell, A., & Neill, A. (2010) · Sleep · doi:10.1093/sleep/33.4.523 · Cited by 55 · cited 1×
“Although these technologies have been shown to be safe and effective, no compliance or clinical benefits have been demonstrated in CPAP-naive patients [5–7].”
BackgroundMulgrew, A. T., Cheema, R., Fleetham, J., Ryan, C. F., & Ayas, N. T. (2007) · Sleep and Breathing · doi:10.1007/s11325-006-0078-6 · Cited by 53 · cited 1×
“A third study was recently published examining auto-titrating CPAP with and without pressure relief in experienced CPAP users [22] There was a subjective preference for the pressure relief mode in this group of patients but only a non-significant trend in terms of greater subjective comfort with the pressure relief mo…”
BackgroundBench testing of auto-adjusting positive airway pressure devices
Abdenbi, F., Chambille, B., & Escourrou, P. (2004) · European Respiratory Journal · doi:10.1183/09031936.04.00133703 · Cited by 49
Fietze, I., Glos, M., Moebus, I., Witt, C., Penzel, T., & Baumann, G. (2007) · Respiration · doi:10.1159/000100364 · Cited by 45 · cited 1×
“The residual AHI on ABPR-PAP is also similar to that reported on APAP [17, 18] and a Bi-Flex® precursor in a traditional bi-level device [19].”
ResultSelf-citationGentina, T., Fortin, F., Douay, B., Dernis, J.-M., Hérengt, F., Jc, B., & Lamblin, C. (2010) · Sleep And Breathing · doi:10.1007/s11325-009-0322-y · Cited by 38
Cited by
Patil, S. P., Ayappa, I. A., Caples, S. M., Kimoff, R. J., Patel, S. R., & Harrod, C. G. (2019) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.7638 · Cited by 721
“,213 One study employed the”
InfluentialIntegrating psychology and medicine in CPAP adherence – New concepts?
Crawford, M., Espie, C. A., Bartlett, D. J., & Grunstein, R. R. (2013) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2013.03.002 · Cited by 120
A multicenter evaluation of oral pressure therapy for the treatment of obstructive sleep apnea
Colrain, I. M., Black, J. E., Siegel, L. C., Bogan, R., Becker, P. M., Farid-Moayer, M., Goldberg, R., Lankford, D. A., Goldberg, A. N., & Malhotra, A. (2013) · Sleep Medicine · doi:10.1016/j.sleep.2013.05.009 · Cited by 84
Sharples, L., Glover, M., Clutterbuck-James, A., Bennett, M., Jordan, J., Chadwick, R., Pittman, M., East, C., Cameron, M., Davies, M., et al. (2014) · Health Technology Assessment · doi:10.3310/hta18670 · Cited by 63
Kennedy, B., Lasserson, T. J., Wozniak, D. R., & Smith, I. (2019) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd003531.pub4 · Cited by 47
Metadata
- Authors
- Blau, A., Minx, M., Peter, J. G., Glos, M., Penzel, T., Baumann, G., & Fietze, I.
- Affiliations
- Charité – Universitätsmedizin Berlin (DE)
- Corresponding author
- Blau, Alexander
- Venue
- Sleep and Breathing
- Published
- 2011-08-27
- Volume
- 16
- Issue
- 3
- Pages
- 773-779
- ISSN
- 1520-9512 (ISSN-L)
- 1522-1709
- OpenAlex
- W2025135842
- Semantic Scholar
- 603893d50e8ed3160333ffd7655423c4ad637102
- Cited by
- 32
- References
- 26
- Citations by year
- 2026: 2 · 2025: 1 · 2024: 1 · 2023: 3 · 2022: 1 · 2019: 4 · 2018: 3 · 2017: 2 · 2016: 4 · 2015: 5 · 2014: 4 · 2013: 2
- FWCI
- 1.31
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Sleep And Breathing (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Respiratory Support and Mechanisms
- Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
- Keywords
- obstructive sleep apnea, continuous positive airway pressure, CPAP adherence, apnea-hypopnea index, CPAP titration
- MeSH terms
- Adult, Aged, Double-Blind Method, Equipment Design, Female, Humans, Male, Middle Aged, Patient Compliance, Pilot Projects, Prospective Studies, Sleep Stages, Therapy, Computer-Assisted, Polysomnography, Sleep Apnea, Obstructive, Continuous Positive Airway Pressure
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).