CoChat

CPAP interface: satisfaction and side effects

The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.

Abstract

Purpose This study aimed to evaluate the care receiver's satisfaction with the continuous positive airway pressure (CPAP) interfaces. Methods A questionnaire with visual analog scales was sent to all our CPAP patients (0 = absolutely unsatisfied, 100 = very satisfied). From the ResMed ResScan program, we obtained the CPAP daily use and air leak values. Results We received 730 answers (70 % of participants); females comprised 22 %. A total of 391 patients had ResMed interfaces, 227 had Respironics, 87 had Fisher & Paykel (F&P), and 25 patients had other interfaces. Interfaces were nasal for 79 %, nasal pillows for 9 %, oronasal for 9 %, and unidentified for 3 % of cases. The mean ± SD satisfaction rate was 68 ± 25. No statistically significant differences were found regarding the type or brand of interface, previous interface experience, or the age or gender of the patient. Users of ResMed interfaces had significantly (p Conclusions The majority of patients consider the use of the CPAP interface disturbing even though the satisfaction rate is good with no differences between brands.

Overview

Integrity signals

Registry

Crossref · 10.1007/s11325-012-0740-0

Cites

23 of 23 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 23 references

Research works printed but not linked: 1

  1. Virkkula P, Rinne J, Bachour A (2008) Kuorsaajan nenä. Duodecim 124:641–648

Cited by

See all 74

Metadata

Authors
Bachour, A., Vitikainen, P., Virkkula, P., & Maasilta, P.
Affiliations
Helsinki University Hospital (FI)
Corresponding author
Bachour, Adel
Venue
Sleep and Breathing
Published
2012-07-05
Volume
17
Issue
2
Pages
667-672
ISSN
  • 1520-9512 (ISSN-L)
  • 1522-1709
OpenAlex
W2038795942
Cited by
68
References
23
Citations by year
2026: 2 · 2025: 3 · 2024: 3 · 2023: 2 · 2022: 2 · 2021: 20 · 2020: 4 · 2019: 9 · 2018: 2 · 2017: 4 · 2016: 8 · 2015: 2 · 2014: 5 · 2012: 2
FWCI
1.93
Type
journal article
Language
en
Open access
closed
Licence
www.springer.com/tdm (tdm)
Locations
  • Sleep And Breathing (publishedVersion)
  • PubMed (publishedVersion)
Funders
ResMed
Topics
  • Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Respiratory Support and Mechanisms
  • Health Sciences › Medicine › Anesthesiology and Pain Medicine › Airway Management and Intubation Techniques
Keywords
patient satisfaction, air leakage, CPAP adherence, CPAP side effects, obstructive sleep apnea
MeSH terms
Adult, Aged, Aged, 80 and over, Equipment Design, Equipment Failure, Female, Humans, Male, Middle Aged, Patient Compliance, Surveys and Questionnaires, Patient Satisfaction, Sleep Apnea, Obstructive, Continuous Positive Airway Pressure, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: CPAP interface: satisfaction and side effects. https://app.cochat.ai/papers/10.1007/s11325-012-0740-0
The paper
Bachour, A., Vitikainen, P., Virkkula, P., & Maasilta, P. (2013). CPAP interface: satisfaction and side effects. Sleep and Breathing. https://doi.org/10.1007/s11325-012-0740-0

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.