Influence of QuEChERS modifications on recovery and matrix effect during the multi-residue pesticide analysis in soil by GC/MS/MS and GC/ECD/NPD
Open accessThe DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
A QuEChERS extraction followed by GC/MS/MS and GC-μECD/NPD for 216 pesticide and metabolites determination in soil simultaneously were developed and compared. Volume of water, volume and polarity of solvent, and cleanup sorbents (C18, GCB, PSA) were optimized. The QuEChERS with and without purification step were applied to estimate effectiveness of the method. The recovery and matrix effect (ME) were critical parameters within each tested procedure. The optimal method without cleanup was validated. Accuracy (expressed as recovery), precision (expressed as RSD), linearity, LOQ, and uncertainty were determined. The recoveries at the three spiking levels using matrix-matched standards ranged between 65 and 116% with RSD ≤17 and 60-112% with RSD ≤18% for MS/MS and μEC/NP, respectively. The LOQ ranged from 0.005-0.01 mg/kg for MS/MS to 0.05 mg/kg for μEC/NP. The ME for most of pesticides resulted in enhancement of the signal and depended on the analyte and detection system: MS/MS showed ME from -25 to 74%, while μEC/NP from -45 to 96%. A principal component analysis was performed to explain the relationships between physicochemical parameters and ME of 216 pesticides. The QuEChERS protocol without the cleanup step is a promising option to make the method less expensive and faster. This methodology was applied in routine analysis of 263 soil samples in which p,p' DDT was the most frequently detected (23.5% of samples) and pendimethalin with the highest concentration (1.63 mg/kg).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Anastassiades, M., Lehotay, S. J., Štajnbaher, D., & Schenck, F. J. (2003) · Journal of AOAC INTERNATIONAL · doi:10.1093/jaoac/86.2.412 · Cited by 5,670 · cited 3×
“It is typical for the GC to observe an enhancement effect resulting from blocking of active column sites by matrix components; thus, more pesticide particles can reach the detector (Anastassiades et al. 2003).”
BackgroundMethodLehotay, S. J., Son, K. A., Kwon, H., Koesukwiwat, U., Fu, W., Mastovska, K., Hoh, E., & Leepipatpiboon, N. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2010.01.044 · Cited by 886 · cited 2×
“Gas chromatography”
BackgroundEvaluation of analyte protectants to improve gas chromatographic analysis of pesticides
Anastassiades, M., Maštovská, K., & Lehotay, S. J. (2003) · Journal of Chromatography A · doi:10.1016/s0021-9673(03)01208-1 · Cited by 368 · cited 2×
“Numerous methods have been proposed to correct its effects, including the use of analyte protestants (Anastassiades et al. 2013), coated inlet liners, compensation factors, different injection techniques, dilution, internal standards, extensive sample cleanup, GC priming, and labeled internal…”
MethodMatrix effects in pesticide multi-residue analysis by liquid chromatography–mass spectrometry
Kruve, A., Künnapas, A., Herodes, K., & Leito, I. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.01.077 · Cited by 322 · cited 1×
“Matrix interferences are one of the major problems of pesticide residue analysis in different matrices because it can suppress or enhance the chromatographic signals (Kruve et al. 2008, Zhang et al. 2011).”
BackgroundBruzzoniti, M. C., Checchini, L., De Carlo, R. M., Orlandini, S., Rivoira, L., & Del Bubba, M. (2014) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-014-7798-4 · Cited by 301 · cited 1×
“Therefore, an existing knowledge needs to be filled (Vera et al. 2013; Bruzzoniti et al. 2014) by finding cheaper and faster method for the simultaneous analysis of pesticides covering a wide range of polarities in complex matrix such as soil that has been carried out.”
MethodCurrent trends in sample preparation for growth promoter and veterinary drug residue analysis
Kinsella, B., O’Mahony, J., Malone, E., Moloney, M., Cantwell, H., Furey, A., & Danaher, M. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.09.005 · Cited by 197
LESUEUR, C. (2008) · Talanta · doi:10.1016/j.talanta.2007.11.031 · Cited by 186 · cited 2×
“Gas chromatography”
MethodHe, Z., Wang, L., Peng, Y., Luo, M., Wang, W., & Liu, X. (2015) · Food Chemistry · doi:10.1016/j.foodchem.2014.07.102 · Cited by 173 · cited 2×
“Gas chromatography”
BackgroundKolberg, D. I., Prestes, O. D., Adaime, M. B., & Zanella, R. (2011) · Food Chemistry · doi:10.1016/j.foodchem.2010.10.041 · Cited by 162 · cited 1×
“In extraction of target pesticides from solid sample, the extraction solvent must be characterized by a high dissolving ability for pesticides and good permeability into the matrix, especially for dry samples (Kolberg et al. 2011).”
BackgroundLozano, A., Rajski, Ł., Belmonte-Valles, N., Uclés, A., Uclés, S., Mezcua, M., & Fernández-Alba, A. R. (2012) · Journal of Chromatography A · doi:10.1016/j.chroma.2012.10.013 · Cited by 159 · cited 1×
“…matrix sample preparations such as: cereals (He et al. 2015), fruit and vegetables (Lehotay et al. 2010), honey (Bargańska et al. 2013), tea (Lozano et al. 2012) and tobacco (Łozowicka et al. 2015), because of its simplicity, low cost, amenability to high throughput, and high efficiency…”
BackgroundMasiá, A. R., Vásquez, K., Campo, J., & Picó, Y. (2014) · Journal of Chromatography A · doi:10.1016/j.chroma.2014.11.079 · Cited by 157 · cited 3×
“Gas chromatography”
BackgroundČajka, T., Sandy, C., Bachanová, V., Drábová, L., Kalachová, K., Pulkrábová, J., & Hajšlová, J. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.06.051 · Cited by 153 · cited 2×
“According to Cajka et al. (2012), adding water to the sample is a key to achieve maximum extraction yield and accurate results.”
BackgroundMethodRashid, A., Nawaz, S., Barker, H., Ahmad, I., & Ashraf, M. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2010.02.060 · Cited by 148 · cited 3×
“…of sensitive detectors such as electron capture (EC) and nitrogen phosphorus (NP) (Łozowicka et al. 2012), mass spectrometry (MS) (Rouvière et al. 2012; Wu and Hu 2014), tandem mass spectrometry (MS/MS) (Rashid et al. 2010) are techniques usually utilized in pesticide residue analysis in soils.”
BackgroundMethodAsensio‐Ramos, M., Hernández‐Borges, J., Ravelo‐Pérez, L. M., & Rodríguez‐Delgado, M. Á. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-009-3440-2 · Cited by 148 · cited 2×
“Asensio-Ramos et al. (2010) observed significant ME for 11 pesticides (buprofezin, chlorpyrifos, chlorpyrifos-methyl, diazinon, dimethoate, ethoprofos, fenirothion, malaoxon, malathion, and phosmet) and in this study no ME was achieved for these substances.”
BackgroundMol, H. G. J., Rooseboom, A., van Dam, R., Roding, M., Arondeus, K., & Sunarto, S. (2007) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1357-1 · Cited by 144 · cited 2×
“These solvents were chosen, because they are commonly used for multi-residue analysis for a wide range of pesticides in different food matrices such as fruit and vegetables (Mol et al. 2007), olive (Moreno López et al.”
MethodLi, Y., Dong, F., Liu, X., Xu, J., Li, J., Kong, Z., Chen, X., Liang, X., & Zheng, Y. (2011) · Journal of Chromatography A · doi:10.1016/j.chroma.2011.12.044 · Cited by 141 · cited 3×
“Gas chromatography”
BackgroundUltrasonic solvent extraction of organochlorine pesticides from soil
Tor, A., Aydın, M. E., & Özcan, S. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.11.078 · Cited by 124 · cited 3×
“Other methods, such as accelerated solvent (ASE) (Rouvière et al. 2012), dispersive liquid-liquid microextraction (DLLME) (Pastor-Belda et al. 2015), matrix solid phase dispersion (MSPD) (Łozowicka et al. 2012), ultrasonic solvent (USE) (Tor et al. 2006), microwave assisted (MAE) (Guo and Lee 2013; Fuentes et al. 2007…”
BackgroundMethodPesticide residues levels in honey from apiaries located of Northern Poland
Bargańska, Ż., Ślebioda, M., & Namieśnik, J. (2012) · Food Control · doi:10.1016/j.foodcont.2012.09.049 · Cited by 115 · cited 2×
“Gas chromatography”
Zhang, K., Wong, J. W., Yang, P., Tech, K., DiBenedetto, A. L., Lee, N. S., Hayward, D. G., Makovi, C. M., Krynitsky, A. J., Banerjee, K., et al. (2011) · Journal of Agricultural and Food Chemistry · doi:10.1021/jf2010723 · Cited by 103
Correia‐Sá, L., Fernandes, V. C., Carvalho, M. M., Calhau, C., Domingues, V. F., & Delerue-Matos, C. M. (2012) · Journal of Separation Science · doi:10.1002/jssc.201200087 · Cited by 103 · cited 3×
“(Asensio-Ramos et al. 2010; Correia-Sá et al. 2012; Li et al. 2012; Fernandes et al. 2013;Mantzos et al. 2013; Masiá et al. 2015).”
ResultNaeeni, M. H., Yamini, Y., & Rezaee, M. B. (2011) · The Journal of Supercritical Fluids · doi:10.1016/j.supflu.2011.03.005 · Cited by 102 · cited 3×
“…et al. 2007), pressurized liquid (PLE) (Martinez Vidal et al. 2010; Masiá et al. 2015), solid phase microextraction (SPME) (Moreno et al. 2006), supercritical fluid extraction (SFE) (Naeeni et al. 2011) have been developed to reduce the amount of reagents and time provided on sample preparation.”
BackgroundFernandes, V. C., Domingues, V. F., Mateus, N. F. D. C. B., & Delerue-Matos, C. M. (2012) · Journal of Separation Science · doi:10.1002/jssc.201200673 · Cited by 90 · cited 3×
“Fernandes et al. (2013) observed ME for 12 pesticides (α- and β-HCH, HCB, endrin, o,p-DDT, bupirimate, chlorpyrifos, fludioxonil, iprodione, malathion, methiocarb, and pendimetaline) from a group of 36 pesticides.”
Arias, J. L. D. O., Rombaldi, C., Caldas, S. S., & Prímel, E. G. (2014) · Journal of Chromatography A · doi:10.1016/j.chroma.2014.07.082 · Cited by 90 · cited 1×
“PE values near 100% indicated recoveries and low matrix effect (Arias et al. 2014).”
BackgroundCaldas, S. S., Bolzan, C. M., Cerqueira, M. B. R., Tomasini, D., Badiale–Furlong, E., Fagundes, C. A., & Prímel, E. G. (2011) · Journal of Agricultural and Food Chemistry · doi:10.1021/jf202878s · Cited by 83
Rouvière, F., Buleté, A., Cren‐Olivé, C., & Arnaudguilhem, C. (2012) · Talanta · doi:10.1016/j.talanta.2012.02.048 · Cited by 80 · cited 5×
“2012), mass spectrometry (MS) (Rouvière et al. 2012; Wu and Hu 2014), tandem mass spectrometry (MS/MS) (Rashid et al.”
BackgroundMethodInfluentialŁozowicka, B., Ilyasova, G., Kaczyński, P., Jankowska, M., Rutkowska, E., Hrynko, I., Mojsak, P., & Szabuńko, J. (2016) · Talanta · doi:10.1016/j.talanta.2016.01.020 · Cited by 74 · cited 1×
“These solvents were chosen, because they are commonly used for multi-residue analysis for a wide range of pesticides in different food matrices such as fruit and vegetables (Mol et al. 2007), olive (Moreno López et al. 2014), sugar beets, and beet molasses (Łozowicka et al. 2016).”
MethodSelf-citationPinto, C. G., Martín, S. H., Pavón, J. L. P., & Cordero, B. M. (2011) · Analytica Chimica Acta · doi:10.1016/j.aca.2011.01.023 · Cited by 63
Fuentes, E., Báez, M. E., & Labra, R. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.08.064 · Cited by 59 · cited 3×
“2006), microwave assisted (MAE) (Guo and Lee 2013; Fuentes et al. 2007), pressurized liquid (PLE) (Martinez Vidal et al.”
BackgroundKaczyński, P., Łozowicka, B., Jankowska, M., & Hrynko, I. (2016) · Talanta · doi:10.1016/j.talanta.2016.02.001 · Cited by 55 · cited 2×
“Gas chromatography”
BackgroundSelf-citationGuo, L., & Lee, H. K. (2013) · Journal of Chromatography A · doi:10.1016/j.chroma.2013.02.067 · Cited by 51 · cited 3×
“Gas chromatography”
BackgroundPastor‐Belda, M., Garrido, I., Campillo, N., Viñas, P., Hellín, P., Flores, P., & Fenoll, J. (2015) · Journal of Chromatography A · doi:10.1016/j.chroma.2015.03.032 · Cited by 45 · cited 3×
“Other methods, such as accelerated solvent (ASE) (Rouvière et al. 2012), dispersive liquid-liquid microextraction (DLLME) (Pastor-Belda et al. 2015), matrix solid phase dispersion (MSPD) (Łozowicka et al. 2012), ultrasonic solvent (USE) (Tor et al. 2006), microwave assisted (MAE) (Guo and Lee 2013; Fuentes et al. 2007…”
BackgroundMethodQuEChERS and soil analysis. An Overview.
Vera, J., Correia‐Sá, L., Paíga, P., Bragança, I., Fernandes, V. C., Domingues, V. F., & Delerue-Matos, C. M. (2013) · Sample Preparation · doi:10.2478/sampre-2013-0006 · Cited by 45 · cited 1×
“Therefore, an existing knowledge needs to be filled (Vera et al. 2013; Bruzzoniti et al. 2014) by finding cheaper and faster method for the simultaneous analysis of pesticides covering a wide range of polarities in complex matrix such as soil that has been carried out.”
MethodVarga, R., Somogyvári, I., Eke, Z., & Torkos, K. (2010) · Talanta · doi:10.1016/j.talanta.2010.11.030 · Cited by 41 · cited 1×
“Another useful parameter in assessing the effectiveness of cleaning by PSA and its combinations of a purification step and without cleanup step and help to choice the most appropriate method was process efficiency (PE) introduced by Varga et al. (2011).”
MethodVidal, J. L. M., Padilla‐Sánchez, J. A., Plaza‐Bolaños, P., Frenich, A. G., & Romero‐González, R. (2010) · Journal of AOAC International · doi:10.1093/jaoac/93.6.1715 · Cited by 40 · cited 3×
“Besides GC, which has some limitation, a perfect complement is high or ultra-high pressure liquid chromatography (HPLC, UHPLC) (Martinez Vidal et al. 2010; Moreno et al. 2006), liquid chromatography–mass spectrometry (LC/MS) (Chen et al. 2010) or tandem mass spectrometry (LC/MS/MS) (Kaczyński et…”
BackgroundSanghi, R., & Kannamkumarath, S. S. (2004) · Journal of Analytical Chemistry · doi:10.1023/b:janc.0000047004.71892.0e · Cited by 36
Moawed, E. A., Abulkibash, A. B., & El-Shahat, M. F. (2015) · Environmental Nanotechnology Monitoring & Management · doi:10.1016/j.enmm.2015.02.001 · Cited by 26
Vega-Moreno, D., Sosa‐Ferrera, Z., & Santana‐Rodríguez, J. J. (2006) · Journal of Agricultural and Food Chemistry · doi:10.1021/jf0614544 · Cited by 13
A method for the simultaneous extraction of seven pesticides from soil and sediment
Harrison, R., Bull, I. D., & Michaelides, K. (2013) · Analytical Methods · doi:10.1039/c3ay26413k · Cited by 9 · cited 1×
“…Laboratory of Pesticide Residues, Chelmonskiego 22, Postal code: 15-195 Bialystok, Poland (LSE) (Durović et al. 2012), solid phase extraction (SPE) (Dąbrowska et al. 2003), ultrasonication in acetone (Harrison et al. 2013), and in soxhlet apparatus extraction (Sanghi and Kannamkumarath 2004).”
Background
Cited by
Narenderan, S. T., Meyyanathan, S. N., & Babu, B. (2020) · Food Research International · doi:10.1016/j.foodres.2020.109141 · Cited by 413
Umapathi, R., Sonwal, S., Lee, M. J., Mohana Rani, G., Lee, E.-S., Jeon, T.-J., Kang, S.-M., Oh, M.-H., & Huh, Y. S. (2021) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2021.214061 · Cited by 349
Santana-Mayor, Á., Socas-Rodríguez, B., Herrera-Herrera, A. V., & Rodríguez-Delgado, M. Á. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.04.018 · Cited by 202
Advancement and New Trends in Analysis of Pesticide Residues in Food: A Comprehensive Review
Wahab, S., Muzammil, K., Nasir, N., Khan, M. S., Ahmad, M. F., Khalid, M., Ahmad, W., Dawria, A., Reddy, L. K. V., & Busayli, A. M. (2022) · Plants · doi:10.3390/plants11091106 · Cited by 191
“Electron capturing detectors (ECD) [127], flame photometric detectors (FPD) [128], nitrogen phosphorus detectors (NPD), and mass selective detectors (MSD) [127] are utilized due to their sensitivity.”
Background
Metadata
- Authors
- Łozowicka, B., Rutkowska, E., & Jankowska, M.
- Venue
- Environmental Science and Pollution Research
- Published
- 2017-01-16
- Volume
- 24
- Issue
- 8
- Pages
- 7124-7138
- ISSN
- 0944-1344 (ISSN-L)
- 1614-7499
- OpenAlex
- W2571920825
- Cited by
- 176
- References
- 38
- FWCI
- 13.14
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.