Potentiometric polyphenol oxidase biosensor for sensitive determination of phenolic micropollutant in environmental samples
The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Abstract
The present study demonstrates the development of polyphenol oxidase (PPO) biosensor for the detection of catechol using strontium copper oxide (SrCuO 2) and polypyrrole nanotubes (PPyNT) matrix. The SrCuO 2 micro-seeds, a perovskite compound, are synthesized by co-precipitation under pH 8.0. The as-synthesized micro-seeds are characterized by scanning electron microscopy (SEM), field emission scanning electron microscopy (FE-SEM), energy-dispersive X-ray spectroscopy (EDX), and X-ray diffraction spectroscopy (XRD). The proposed sensor is fabricated on pencil graphite (P-Gr) by successive deposition of PPyNT, SrCuO 2, and PPO enzyme. The developed PPO/SrCuO 2/PPyNT/P-Gr sensor is characterized by cyclic voltammetry (CV), differential pulse voltammetry (DPV), and electrochemical impedance spectroscopy (EIS) techniques. The PPO/SrCuO 2/PPyNT/P-Gr displayed excellent electrocatalytic activity towards the oxidation and detection of catechol. The as-developed sensor showed sensitive response ascribing to limit of detection (LOD) of 0.15 μM and sensitivity of 15.60 μA μM-1 cm-2. The fabricated sensor exhibited excellent repeatability and longer shelf life. The proposed biosensor finds its application within the broad linear range of 1-50 μM. Real sample analysis of mineral water, tap water, and domestic wastewater using developed sensor showed acceptable recovery. Hence, the biosensor endeavors its application in environmental monitoring and protection.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“For instance, Yashas et al. [84] constructed a polyphenol oxidase biosensor for catechol detection utilizing a SrCuO 2 and polypyrrole nanotube matrix.The sensor demonstrated high sensitivity, with a detection limit of 0.15 μM and a sensitivity of 15.60 μA/(μM•cm 2 ).It also exhibited excellent repeatability and extended shelf life, making it suitable for environmental monitoring and protection.”
From Design Strategies and Emerging Applications of Perovskite-Based Sensors (2025) · cites this paper as [84]
In the citing paper
“In these sensors, perovskite materials act as electrodes or sensing interfaces, forming the sensitive layer of the sensor in conjunction with the enzyme [84].”
From Design Strategies and Emerging Applications of Perovskite-Based Sensors (2025) · cites this paper as [84]
Citations
Cites
Facile Fabrication of Functional Polypyrrole Nanotubes via a Reactive Self‐Degraded Template
Yang, X., Zhu, Z., Dai, T., & Lu, Y. (2005) · Macromolecular Rapid Communications · doi:10.1002/marc.200500514 · Cited by 334
Enhanced visible-light photocatalytic activity of strontium-doped zinc oxide nanoparticles
Yousefi, R., Jamali-Sheini, F., Cheraghizade, M., Khosravi-Gandomani, S., Sáaedi, A., Huang, N. M., Basirun, W. J., & Azarang, M. (2015) · Materials Science in Semiconductor Processing · doi:10.1016/j.mssp.2015.01.013 · Cited by 195
Li, J., Xia, J., Zhang, F., Wang, Z., & Liu, Q. (2018) · Talanta · doi:10.1016/j.talanta.2018.01.002 · Cited by 182
Zhu, Y. C., Zeng, G., Zhang, Y., Tang, L., Chen, J. S., Cheng, M., Zhang, L., He, L., Guo, Y., He, X., et al. (2014) · The Analyst · doi:10.1039/c4an00874j · Cited by 130
Wang, H., Wu, Y., & Yan, X. (2013) · Analytical Chemistry · doi:10.1021/ac303374s · Cited by 124
A reduced graphene oxide based biosensor for high-sensitive detection of phenols in water samples
Zhou, X., Liu, L., Bai, X., & Shi, H. (2013) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2013.02.021 · Cited by 117
Vicentini, F. C., Garcia, L. L. C., Figueiredo‐Filho, L. C. S., Janegitz, B. C., & Fatibello‐Filho, O. (2015) · Enzyme and Microbial Technology · doi:10.1016/j.enzmictec.2015.12.004 · Cited by 115
Zhang, Y., Sun, R., Luo, B., & Wang, L. (2014) · Electrochimica Acta · doi:10.1016/j.electacta.2014.12.156 · Cited by 108
Umasankar, Y., Periasamy, A. P., & Chen, S. (2010) · Analytical Biochemistry · doi:10.1016/j.ab.2010.12.002 · Cited by 106
Trchová, M., & Stejskal, J. (2018) · The Journal of Physical Chemistry A · doi:10.1021/acs.jpca.8b09794 · Cited by 105
Research works printed but not linked: 1
- Swamy NK, Sandeep S, Santhosh AS (2017) Conductive polymers and their nanohybrid transducers for electrochemical biosensors applications : a brief review. J Adv Chem Sci S2:6–9. https://doi.org/10.22607/IJACS.2017.S02002 · doi:10.22607/ijacs.2017.s02002
Cited by
Kumari, S. M. N. S., & Xavier, T. S. (2024) · ACS Omega · doi:10.1021/acsomega.4c07991 · Cited by 127
Advanced sensing technologies of phenolic compounds for pharmaceutical and biomedical analysis
Ge, L., Li, S., & Lisak, G. (2019) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2019.112913 · Cited by 94
Meskher, H., & Achi, F. (2022) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2022.2114784 · Cited by 85
Yashas, S. R., Shahmoradi, B., Wantala, K., & Shivaraju, H. P. (2021) · Polymer · doi:10.1016/j.polymer.2021.124184 · Cited by 75
Self-citationLi, D., Cheng, Y., Zuo, H., Zhang, W., Pan, G., Fu, Y., & Weı, Q. (2021) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2021.06.155 · Cited by 73
3D hierarchical LDHs-based Janus micro-actuator for detection and degradation of catechol
Xing, N., Lyu, Y., Li, J., Ng, D. H. L., Zhang, X., & Zhao, W. (2022) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2022.129914 · Cited by 42
Design Strategies and Emerging Applications of Perovskite-Based Sensors
Li, Y., Ding, Y., Sun, J., Tan, S., Li, Y., Wang, X., Cai, J., Bai, J., Lv, X., Guo, W., et al. (2025) · SmartMat · doi:10.1002/smm2.70022 · Cited by 41
“In these sensors, perovskite materials act as electrodes or sensing interfaces, forming the sensitive layer of the sensor in conjunction with the enzyme [84].”
Naik, T. S. S. K., Kesavan, A. V., Swamy, B. E. K., Singh, S., Anil, A. G., Madhavi, V., & Ramamurthy, P. C. (2021) · Materials Chemistry and Physics · doi:10.1016/j.matchemphys.2021.125663 · Cited by 36
Sneha, Y., Yashas, S. R., Tenzin, T., Prabagar, J. S., & Shivaraju, H. P. (2022) · Environmental Science and Pollution Research · doi:10.1007/s11356-022-20540-3 · Cited by 35
Self-citationYashas, S. R., Sandeep, S., Shivakumar, B. P., & Swamy, N. K. (2019) · Analytical Methods · doi:10.1039/c9ay01468c · Cited by 34
Self-citationElectrochemical biosensor based on three components random conjugated polymer with fullerene (C60)
Kurbanoğlu, S., Cevher, Ş. C., Toppare, L. K., Çırpan, A., & Söylemez, S. (2022) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2022.108219 · Cited by 34
Kapan, B., Kurbanoğlu, S., Esentürk, E. N., Söylemez, S., & Toppare, L. K. (2021) · Process Biochemistry · doi:10.1016/j.procbio.2021.06.004 · Cited by 28
Yashas, S. R., Shivaraju, H. P., Sandeep, S., Swamy, N. K., & Gurupadayya, B. (2022) · Surfaces and Interfaces · doi:10.1016/j.surfin.2022.102102 · Cited by 27
Self-citationSwamy, N. K., Mohana, K. N. S., & Madhukar, B. S. (2023) · Polymers for Advanced Technologies · doi:10.1002/pat.6246 · Cited by 24
Self-citationAnalytical performance of functional nanostructured biointerfaces for sensing phenolic compounds
Bensana, A., & Achi, F. (2020) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2020.111344 · Cited by 15
Enzymatic biosensors for the detection of water pollutants
Reynoso, E. C., Romero‐Guido, C., Rebollar-Pérez, G., & Torres, E. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-824436-4.00012-5 · Cited by 15
Sachith, B. M., Sandeep, S., NANDINI, S. G., Nalini, S., Karthik, C. S., Swamy, N. K., Mallu, P., & Manjunath, J. G. (2020) · Surfaces and Interfaces · doi:10.1016/j.surfin.2020.100603 · Cited by 15
Self-citationYang, X., Liu, C. R., Gao, S., Zhang, X., Lan, Z., Zuo, M., & Li, J. (2024) · Environmental Science Nano · doi:10.1039/d3en00732d · Cited by 14
Swathi, S., Yuvakkumar, R., Ravi, G., Shanthini, M., Al-Sehemi, A. G., Thambidurai, M., Nguyen, H. D., & Velauthapillai, D. (2022) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2022.167001 · Cited by 13
Advances and Application of Polyphenol Oxidase Immobilization Technology in Plants
Zhou, F., Lin, H., Luo, Y., & Liu, C. (2025) · Plants · doi:10.3390/plants14152335 · Cited by 12
Polyphenol-functionalized biosensors for real-time monitoring of oxidative stress and inflammation
Chen, H., Jia, H., Wang, W., Cai, Q., Sun, J., & Cui, C. (2025) · Industrial Crops and Products · doi:10.1016/j.indcrop.2025.121658 · Cited by 12
Perchikov, R. N., Provotorova, D. V., Kharkova, A. S., Arlyapov, V. A., Medvedeva, A. S., Валериевич, М. А., Филонов, А. Е., & Reshetilov, A. N. (2022) · Polymers · doi:10.3390/polym14245366 · Cited by 12
Swamy, N. K., Mohana, K. N. S., Madhusudhana, A. M., Manjunatha, J. G., & Manukumar, H. M. (2024) · Results in Chemistry · doi:10.1016/j.rechem.2024.101393 · Cited by 11
Self-citationAbhishek, S. M., Swamy, N. K., Yashas, S. R., Shivaraju, H. P., & Chamaraja, N. A. (2022) · Journal of Materials Science Materials in Electronics · doi:10.1007/s10854-022-08193-x · Cited by 10
Self-citationHegde, M. B., Mohana, K. N. S., Madhusudhana, A. M., Vinay, M. M., Nayaka, Y. A., & Swamy, N. K. (2021) · Graphene and 2D Materials Technologies · doi:10.1007/s41127-021-00042-8 · Cited by 8
Self-citationBiosensor based on MXene-Y2O3 composite for ultrasensitive detection of catechol in water samples
Chen, H., Xia, G., Chen, J., & Zheng, H. (2024) · International Journal of Electrochemical Science · doi:10.1016/j.ijoes.2024.100823 · Cited by 6
Mesoporous WO 3 ‐Dot‐Decorated Flexible Electrodes for the Determination of Industrial Pollutants
Koyappayil, A., Seok, H., Choi, G. H., Chavan, S. G., Yeon, S., Son, S., Go, A., Lee, J.-H., Kim, K., Lee, D., et al. (2024) · Energy & environment materials · doi:10.1002/eem2.12842 · Cited by 6
Veerananje, I., Prabhuswamy, V. B., Prakash, B. K. S., Naik, C., Prasanna, S. B., & Ningappa, K. S. (2026) · Journal of Materials Science Materials in Electronics · doi:10.1007/s10854-026-17559-4 · Cited by 2
Shivakumar, V., Ningappa, K. S., Marenahalli, B. L., Shivarudraiah, V. H., Mahesh, B., Chamaraja, N. A., Prasanna, S. B., & Fan, Y.-J. (2025) · Electrocatalysis · doi:10.1007/s12678-025-00999-7
Metadata
- Authors
- Yashas, S. R., Sandeep, S., Shivakumar, B. P., & Swamy, N. K.
- Affiliations
- JSS Science and Technology University (IN)
- Corresponding author
- Swamy, Ningappa Kumara
- Venue
- Environmental Science and Pollution Research
- Published
- 2019-05-27
- Volume
- 27
- Issue
- 22
- Pages
- 27234-27243
- ISSN
- 0944-1344 (ISSN-L)
- 1614-7499
- OpenAlex
- W2947108521
- Cited by
- 29
- References
- 41
- Citations by year
- 2026: 1 · 2025: 4 · 2024: 5 · 2023: 1 · 2022: 9 · 2021: 5 · 2020: 2 · 2019: 2
- FWCI
- 1.62
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- www.springer.com/tdm (vor)
- Locations
- Environmental Science and Pollution Research (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
- Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
- Keywords
- catechol detection, polypyrrole nanotubes, pencil graphite electrode, electrocatalytic oxidation, potentiometric sensing, domestic wastewater, drinking water analysis, environmental monitoring
- MeSH terms
- Catechol Oxidase, Electrodes, Graphite, Polymers, Pyrroles, Biosensing Techniques, Electrochemical Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.