Potentiometric polyphenol oxidase biosensor for sensitive determination of phenolic micropollutant in environmental samples
The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Abstract
The present study demonstrates the development of polyphenol oxidase (PPO) biosensor for the detection of catechol using strontium copper oxide (SrCuO 2) and polypyrrole nanotubes (PPyNT) matrix. The SrCuO 2 micro-seeds, a perovskite compound, are synthesized by co-precipitation under pH 8.0. The as-synthesized micro-seeds are characterized by scanning electron microscopy (SEM), field emission scanning electron microscopy (FE-SEM), energy-dispersive X-ray spectroscopy (EDX), and X-ray diffraction spectroscopy (XRD). The proposed sensor is fabricated on pencil graphite (P-Gr) by successive deposition of PPyNT, SrCuO 2, and PPO enzyme. The developed PPO/SrCuO 2/PPyNT/P-Gr sensor is characterized by cyclic voltammetry (CV), differential pulse voltammetry (DPV), and electrochemical impedance spectroscopy (EIS) techniques. The PPO/SrCuO 2/PPyNT/P-Gr displayed excellent electrocatalytic activity towards the oxidation and detection of catechol. The as-developed sensor showed sensitive response ascribing to limit of detection (LOD) of 0.15 μM and sensitivity of 15.60 μA μM-1 cm-2. The fabricated sensor exhibited excellent repeatability and longer shelf life. The proposed biosensor finds its application within the broad linear range of 1-50 μM. Real sample analysis of mineral water, tap water, and domestic wastewater using developed sensor showed acceptable recovery. Hence, the biosensor endeavors its application in environmental monitoring and protection.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“For instance, Yashas et al. [84] constructed a polyphenol oxidase biosensor for catechol detection utilizing a SrCuO 2 and polypyrrole nanotube matrix.The sensor demonstrated high sensitivity, with a detection limit of 0.15 μM and a sensitivity of 15.60 μA/(μM•cm 2 ).It also exhibited excellent repeatability and extended shelf life, making it suitable for environmental monitoring and protection.”
From Design Strategies and Emerging Applications of Perovskite-Based Sensors (2025) · cites this paper as [84]
In the citing paper
“In these sensors, perovskite materials act as electrodes or sensing interfaces, forming the sensitive layer of the sensor in conjunction with the enzyme [84].”
From Design Strategies and Emerging Applications of Perovskite-Based Sensors (2025) · cites this paper as [84]
Citations
Cites
Facile Fabrication of Functional Polypyrrole Nanotubes via a Reactive Self‐Degraded Template
Yang, X., Zhu, Z., Dai, T., & Lu, Y. (2005) · Macromolecular Rapid Communications · doi:10.1002/marc.200500514 · Cited by 334
Enhanced visible-light photocatalytic activity of strontium-doped zinc oxide nanoparticles
Yousefi, R., Jamali-Sheini, F., Cheraghizade, M., Khosravi-Gandomani, S., Sáaedi, A., Huang, N. M., Basirun, W. J., & Azarang, M. (2015) · Materials Science in Semiconductor Processing · doi:10.1016/j.mssp.2015.01.013 · Cited by 195
Li, J., Xia, J., Zhang, F., Wang, Z., & Liu, Q. (2018) · Talanta · doi:10.1016/j.talanta.2018.01.002 · Cited by 182
Zhu, Y. C., Zeng, G., Zhang, Y., Tang, L., Chen, J. S., Cheng, M., Zhang, L., He, L., Guo, Y., He, X., et al. (2014) · The Analyst · doi:10.1039/c4an00874j · Cited by 130
Wang, H., Wu, Y., & Yan, X. (2013) · Analytical Chemistry · doi:10.1021/ac303374s · Cited by 124
A reduced graphene oxide based biosensor for high-sensitive detection of phenols in water samples
Zhou, X., Liu, L., Bai, X., & Shi, H. (2013) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2013.02.021 · Cited by 117
Vicentini, F. C., Garcia, L. L. C., Figueiredo‐Filho, L. C. S., Janegitz, B. C., & Fatibello‐Filho, O. (2015) · Enzyme and Microbial Technology · doi:10.1016/j.enzmictec.2015.12.004 · Cited by 115
Zhang, Y., Sun, R., Luo, B., & Wang, L. (2014) · Electrochimica Acta · doi:10.1016/j.electacta.2014.12.156 · Cited by 108
Umasankar, Y., Periasamy, A. P., & Chen, S. (2010) · Analytical Biochemistry · doi:10.1016/j.ab.2010.12.002 · Cited by 106
Trchová, M., & Stejskal, J. (2018) · The Journal of Physical Chemistry A · doi:10.1021/acs.jpca.8b09794 · Cited by 105
Electrochemical biosensor for catechol using agarose–guar gum entrapped tyrosinase
Tembe, S., Inamdar, S. N., Haram, S. K., KARVE, M. S., & D’Souza, S. F. (2006) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2006.09.020 · Cited by 103
Graphene oxide–ZnO nanocomposite modified electrode for the detection of phenol
Arfin, T., & Rangari, S. (2018) · Analytical Methods · doi:10.1039/c7ay02650a · Cited by 92
Fabrication of Cu nano particles by direct electrochemical reduction from CuO nano particles
Han, W.-K., Choi, J., Hwang, G.-H., Hong, S., Lee, J., & Kang, S.-G. (2005) · Applied Surface Science · doi:10.1016/j.apsusc.2005.04.049 · Cited by 86
Catalytic wet peroxide oxidation of phenol over Fe2O3/MCM-41 in a fixed bed reactor
Yan, Y. C., Xiangwu, W., & Zhang, H. (2016) · Separation and Purification Technology · doi:10.1016/j.seppur.2016.06.047 · Cited by 82
Fartas, F. M., Abdullah, J., Yusof, N. A., Sulaiman, Y., & Saiman, M. I. (2017) · Sensors · doi:10.3390/s17051132 · Cited by 82
Ameer, Q., & Adeloju, S. B. O. (2009) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2009.03.056 · Cited by 77
Bansal, P., Bhanjana, G., Prabhakar, N., Dhau, J. S., & Chaudhary, G. R. (2017) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2017.10.098 · Cited by 76
Feng, S., Zhang, Y., Zhong, Y., Li, Y., & Li, S. (2014) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2014.09.019 · Cited by 72
Nazari, M., Kashanian, S., Moradipour, P., & Maleki, N. (2018) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2018.01.058 · Cited by 72
Singh, S. B., Jain, D., & Singla, M. L. (2013) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2013.02.111 · Cited by 65
Zeng, G., Zhu, Y. C., Zhang, Y., Zhang, C., Tang, L., Guo, P.-C., Zhang, L., Yuan, Y., Cheng, M., & Yang, C. (2016) · Environmental Science Nano · doi:10.1039/c6en00323k · Cited by 63
Kopecký, D., Varga, M., Prokeš, J., Vrňata, M., Trchová, M., Kopecká, J., & Václavík, M. (2017) · Synthetic Metals · doi:10.1016/j.synthmet.2017.06.004 · Cited by 59
Polyphenol oxidase (PPO) based biosensors for detection of phenolic compounds: A Review
Gul, I., Ahmad, M. S., Naqvi, S. S., Hussain, A., Wali, R., Farooqi, A. A., & Ahmed, I. (2017) · Journal of Applied Biology & Biotechnology · doi:10.7324/jabb.2017.50313 · Cited by 58
(2008) · International Union of Pure and Applied Chemistry (IUPAC) eBooks · doi:10.1351/goldbook.l03540 · Cited by 57
Aziz, A. A., Yong, K. S., Ibrahim, S. B., & Saravanan, P. (2011) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2011.10.069 · Cited by 55
Liu, Z., Zhang, Y., Bian, C., Xia, T., Gao, Y., Zhang, X., Wang, H., Ma, H., Hu, Y., & Wang, X. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.10.050 · Cited by 52
Sandeep, S., Shivamurthy, S. A., Swamy, N. K., Suresh, G. S., Melo, J. S., & Chamaraja, N. A. (2018) · New Journal of Chemistry · doi:10.1039/c8nj02325e · Cited by 51
Self-citationElancheziyan, M., Manoj, D., Saravanakumar, D., Thenmozhi, K., & Senthilkumar, S. (2017) · Microchimica Acta · doi:10.1007/s00604-017-2312-2 · Cited by 50
Maringa, A., Mugadza, T., Antunes, E. M., & Nyokong, T. (2013) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2013.04.022 · Cited by 45
de Lima, F., Lucca, B. G., Barbosa, A. M. J., Ferreira, V. S., Moccelini, S. K., Franzoi, A. C., & Vieira, I. C. (2010) · Enzyme and Microbial Technology · doi:10.1016/j.enzmictec.2010.05.006 · Cited by 42
Nandini, S., Nalini, S., Sanetuntikul, J., Shanmugam, S., Niranjana, P., Melo, J. S., & Suresh, G. S. (2014) · The Analyst · doi:10.1039/c4an01262c · Cited by 37
Sandeep, S., Shivamurthy, S. A., Swamy, N. K., Suresh, G. S., Melo, J. S., & Subramani, N. K. (2018) · Materials Science and Engineering B · doi:10.1016/j.mseb.2018.10.014 · Cited by 36
Self-citationMa, L., & Zhao, G. (2012) · International Journal of Electrochemistry · doi:10.1155/2012/243031 · Cited by 34
David, I. G., Badea, I. A., & Radu, G. L. (2013) · TURKISH JOURNAL OF CHEMISTRY · doi:10.3906/kim-1203-49 · Cited by 27
Balasubramanian, P., Balamurugan, T. S. T., Chen, S.-M., & Chen, T.-W. (2017) · Journal of the Taiwan Institute of Chemical Engineers · doi:10.1016/j.jtice.2017.10.040 · Cited by 26
Laccase Biosensor: Green Technique for Quantification of Phenols in Wastewater
Yashas, S. R., P, S. B., H, U. T., & Krishna, B. M. (2018) · Oriental Journal Of Chemistry · doi:10.13005/ojc/340204 · Cited by 24
Self-citationLi, H., Hu, X. D., Zhu, H., Zang, Y., & Xue, H. (2017) · International Journal of Electrochemical Science · doi:10.20964/2017.07.80 · Cited by 23
Usai, V., Mugadza, T., Chigondo, F., Shumba, M., Nharingo, T., Moyo, M., & Tshuma, P. (2018) · Polyhedron · doi:10.1016/j.poly.2018.10.002 · Cited by 19
Catechol biodegradation by a novel hybrid anoxic biofilter
Khorsandi, H., Gholizadeh, M., & Aghapour, A. A. (2018) · Environmental Technology · doi:10.1080/09593330.2018.1510434 · Cited by 10
Polypyrrole Micro/Nanostructure Prepared Using Azo Dyes with Different Substituents
Kopecký, D., Škodová, J., Vrňata, M., & Fitl, P. (2012) · Advances in Materials Physics and Chemistry · doi:10.4236/ampc.2012.24b024 · Cited by 7
(2008) · International Union of Pure and Applied Chemistry (IUPAC) eBooks · doi:10.1351/goldbook.s05606 · Cited by 6
Research works printed but not linked: 1
- Swamy NK, Sandeep S, Santhosh AS (2017) Conductive polymers and their nanohybrid transducers for electrochemical biosensors applications : a brief review. J Adv Chem Sci S2:6–9. https://doi.org/10.22607/IJACS.2017.S02002 · doi:10.22607/ijacs.2017.s02002
Cited by
Kumari, S. M. N. S., & Xavier, T. S. (2024) · ACS Omega · doi:10.1021/acsomega.4c07991 · Cited by 127
Advanced sensing technologies of phenolic compounds for pharmaceutical and biomedical analysis
Ge, L., Li, S., & Lisak, G. (2019) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2019.112913 · Cited by 94
Meskher, H., & Achi, F. (2022) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2022.2114784 · Cited by 85
Yashas, S. R., Shahmoradi, B., Wantala, K., & Shivaraju, H. P. (2021) · Polymer · doi:10.1016/j.polymer.2021.124184 · Cited by 75
Self-citationLi, D., Cheng, Y., Zuo, H., Zhang, W., Pan, G., Fu, Y., & Weı, Q. (2021) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2021.06.155 · Cited by 73
Metadata
- Authors
- Yashas, S. R., Sandeep, S., Shivakumar, B. P., & Swamy, N. K.
- Affiliations
- JSS Science and Technology University (IN)
- Corresponding author
- Swamy, Ningappa Kumara
- Venue
- Environmental Science and Pollution Research
- Published
- 2019-05-27
- Volume
- 27
- Issue
- 22
- Pages
- 27234-27243
- ISSN
- 0944-1344 (ISSN-L)
- 1614-7499
- OpenAlex
- W2947108521
- Cited by
- 29
- References
- 41
- Citations by year
- 2026: 1 · 2025: 4 · 2024: 5 · 2023: 1 · 2022: 9 · 2021: 5 · 2020: 2 · 2019: 2
- FWCI
- 1.62
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- www.springer.com/tdm (vor)
- Locations
- Environmental Science and Pollution Research (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
- Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
- Keywords
- catechol detection, polypyrrole nanotubes, pencil graphite electrode, electrocatalytic oxidation, potentiometric sensing, domestic wastewater, drinking water analysis, environmental monitoring
- MeSH terms
- Catechol Oxidase, Electrodes, Graphite, Polymers, Pyrroles, Biosensing Techniques, Electrochemical Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.