Localized Surface Plasmon Resonance-Based Fiber Optic U-Shaped Biosensor for the Detection of Blood Glucose
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A study of the nucleation and growth processes in the synthesis of colloidal gold
Turkevich, J., Stevenson, P. C., & Hillier, J. (1951) · Discussions of the Faraday Society · doi:10.1039/df9511100055 · Cited by 7,792 · cited 1×
“The method is named as Turkevich method [16].”
MethodExploitation of Localized Surface Plasmon Resonance
Hutter, E., & Fendler, J. H. (2004) · Advanced Materials · doi:10.1002/adma.200400271 · Cited by 2,726 · cited 1×
“observed in the extinction spectrum of the metal nanoparticles [6].”
BackgroundGlucose Biosensors: An Overview of Use in Clinical Practice
Yoo, E.-H., & Lee, S.-Y. (2010) · Sensors · doi:10.3390/s100504558 · Cited by 1,137 · cited 1×
“The selectivity and specificity of glucose oxidase to glucose have already been well studied and established [20].”
BackgroundTheranostic Nanoshells: From Probe Design to Imaging and Treatment of Cancer
Bardhan, R., Lal, S., Joshi, A., & Halas, N. J. (2011) · Accounts of Chemical Research · doi:10.1021/ar200023x · Cited by 917 · cited 1×
“In the beginning, the research on the plasmonic properties of metal nanostructures was primarily in the fields of sensing and subwavelength optical components and devices, but nowadays, it has reached to single-photon imaging, surface plasmon amplification by stimulated emission of radiation, optical antennas, treatme…”
BackgroundA unified view of propagating and localized surface plasmon resonance biosensors
Haes, A. J., & Van Duyne, R. P. (2004) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-004-2708-9 · Cited by 666 · cited 1×
“The LSPR-based sensors have been found to be less sensitive in wavelength modulation scheme and hence are generally preferred in intensity modulation scheme [19].”
BackgroundZhang, S., Wang, N., Yu, H., Niu, Y., & Sun, C. (2005) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2004.12.002 · Cited by 317 · cited 3×
“Most of these use electrochemical methods [14, 15].”
BackgroundResultFibre-optic evanescent field absorption sensor based on a U-shaped probe
Gupta, B. D., Dodeja, H., & Tomar, A. K. (1996) · Optical and Quantum Electronics · doi:10.1007/bf00331053 · Cited by 209 · cited 1×
“[10] used oxy-butane flame to make U-shaped probes of optical fibers for evanescent wave sensing.”
MethodSelf-citationRacial Differences in Adiponectin in Youth: Relationship to visceral fat and insulin sensitivityv
Lee, S. (2006) · Diabetes Care · doi:10.2337/diacare.29.1.51 · Cited by 90
Continuous Blood Glucose Monitoring with a Thin-Film Optical Sensor
Worsley, G. J., Tourniaire, G., Medlock, K. E. S., Sartain, F. K., Harmer, H. E., Thatcher, M., Horgan, A. M., & Pritchard, J. (2007) · Clinical Chemistry · doi:10.1373/clinchem.2007.091629 · Cited by 63 · cited 1×
“5 ml of blood [22, 23].”
Enzyme-Based Fiber Optic Sensor for Glucose Determination
Abdel‐Latif, M. S., Suleiman, A. A., & Guilbault, G. G. (1988) · Analytical Letters · doi:10.1080/00032718808071922 · Cited by 34
Cited by
Gold nanorod-based localized surface plasmon resonance biosensors: A review
Cao, J., Sun, T., & Grattan, K. T. V. (2014) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2014.01.056 · Cited by 768
Review of plasmonic fiber optic biochemical sensors: improving the limit of detection
Caucheteur, C., Guo, T., & Albert, J. (2015) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-014-8411-6 · Cited by 729
Current status of optical fiber biosensor based on surface plasmon resonance
Zhao, Y., Tong, R.-J., Xia, F., & Peng, Y. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.111505 · Cited by 507
Optical Fiber Sensors: Working Principle, Applications, and Limitations
Elsherif, M., Salih, A. E., Muñoz, M. G., Alam, F., AlQattan, B., Antonysamy, D. S., Zaki, M. F., Yetisen, A. K., Park, S., Wilkinson, T. D., et al. (2022) · Advanced Photonics Research · doi:10.1002/adpr.202100371 · Cited by 330
Metadata
- Authors
- Srivastava, S. K., Arora, V., Sapra, S., & Gupta, B. D.
- Venue
- Plasmonics
- Published
- 2011-11-09
- Volume
- 7
- Issue
- 2
- Pages
- 261-268
- ISSN
- 1557-1955 (ISSN-L)
- 1557-1963
- OpenAlex
- W1993804196
- Cited by
- 165
- References
- 11
- FWCI
- 3.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.