Input impedance of distributed arterial structures as used in investigations of underlying concepts in arterial haemodynamics
The DOI matches its Crossref record; 50 of the 50 references it cites were found in a registry or an index.
Abstract
By definition, vascular impedance is described in the frequency domain as the ratio of sinusoidal functions of pressure and flow, yielding spectral values of impedance modulus and phase. The impedance spectrum is determined by the structure and physical properties of the vascular system, such that for a given system the relation between pressure and flow can be modified by alteration of the geometric or mechanical properties of the vascular segments. Whereas input impedance of an arterial system can be readily determined by simultaneous measurement of just two time varying signals of blood pressure and flow, the production of the same impedance spectrum from the physical properties of the system would require information of inordinate complexity and magnitude. Hence, arterial models with a tractable number of parameters or explicit mathematical description are used to approximate the physiological impedance of a vascular structure, which in all animal species consists of distributed branching arterial networks. Although models are a necessary approximation, the strong similarity between the impedance spectra of models and physiological arterial systems enables investigations of fundamental concepts. This is illustrated by examining the effect of the branching structure on the decoupling of the high peripheral resistance from the ejecting ventricles and how physical parameters derived from the impedance spectrum can be used to investigate concepts of optimal design and features related to body size across a broad range of animal species.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“It has been very successful and is now, by far, the most common approach to arterial mechanics [3, 31, 37, 54].”
From A brief history of arterial wave mechanics (2009) · cites this paper as [3]
Citations
Cites
Scaling: Why is Animal Size so Important?
Schmidt-Nielsen, K. (1984) · doi:10.1017/cbo9781139167826 · Cited by 2,677
Scaling Why is animal size so important?
Schmidt‐Nielsen, K. (1984) · Cited by 2,654
McDonald's Blood Flow in Arteries: Theoretical, Experimental and Clinical Principles
Vlachopoulos, C., O'Rourke, M., & Nichols, W. W. (2011) · doi:10.1201/b13568 · Cited by 1,613
Analog studies of the human systemic arterial tree
Westerhof, N., Bosman, F., De Vries, C. J., & Noordergraaf, A. (1969) · Journal of Biomechanics · doi:10.1016/0021-9290(69)90024-4 · Cited by 684 · cited 1×
“This is done by using transmission line analogies by assigning equivalent resistance, capacitance and inductance values per unit length, and arterial segments can be described as a series and parallel network of uniform tubes [3, 35, 43, 44 , 47].”
MethodAn artificial arterial system for pumping hearts.
Westerhof, N., Elzinga, G., & Sipkema, P. (1971) · Journal of Applied Physiology · doi:10.1152/jappl.1971.31.5.776 · Cited by 556
Multi-branched model of the human arterial system
Avolio, A. P. (1980) · Medical & Biological Engineering & Computing · doi:10.1007/bf02441895 · Cited by 517
Self-citationComputer simulation of arterial flow with applications to arterial and aortic stenoses
Stergiopulos, N., Young, D. F., & Rogge, T. R. (1992) · Journal of Biomechanics · doi:10.1016/0021-9290(92)90060-e · Cited by 511
McDonaldʼs Blood Flow in Arteries: Theoretical, Experimental and Clinical Principles, ed. 3
Nichols, W. W., OʼRourke, M. F., & Kenney, W. L. (1991) · Journal of Cardiopulmonary Rehabilitation · doi:10.1097/00008483-199111000-00023 · Cited by 451
Optimality Principles in Biology
Rosen, R. (1967) · Springer eBooks · doi:10.1007/978-1-4899-6419-9 · Cited by 399
Smulyan, H., Marchais, S. J., Pannier, B., Guerin, A. P., Safar, M. E., & London, G. M. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00056-4 · Cited by 242
Research works printed but not linked: 4
- Avolio AP (1976) Haemodynamic studies and modeling of the mammalian arterial system. PhD Thesis, University of New South Wales, Sydney
- Nichols WW, O’Rourke MF (2005) McDonald’s blood flow in arteries. Arnold, London
- Rashevsky N (1960) Mathematical biology. Dover, New York
- Taylor MG (1969) In: Fishman AP, Hecht HH (eds) The pulmonary circulation and interstitial space. University of Chicago Press, Chicago
Cited by
A brief history of arterial wave mechanics
Parker, K. H. (2009) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-009-0440-5 · Cited by 137
Theoretical models for coronary vascular biomechanics: Progress & challenges
Waters, S. L., Alastruey, J., Beard, D. A., Bovendeerd, P. H. M., Davies, P. F., Jayaraman, G., Jensen, O. E., Lee, J., Parker, K. H., Popel, A. S., et al. (2010) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2010.10.001 · Cited by 83
“The 1D formulation has also been used to derivemethods for the analysis of in vivo pressure and velocity measurements in both the time and frequency domains (Avolio, 2009; van den Wijngaard et al., 2009; Hughes and Parker, 2009).”
Hunter, K. S., Lammers, S. R., & Shandas, R. (2011) · Comprehensive physiology · doi:10.1002/cphy.c100005 · Cited by 55
“For these reasons, distributed parameter models have primarily been used in the systemic circulation to investigate wave transmission phenomenon such as transmission and reflection (71, 129), and to explore relationships between impedance and the components that define it (3): vascular geometry including vessel diamet…”
Chan, G. S. H., Ainslie, P. N., Willie, C. K., Taylor, C. E., Atkinson, G., Jones, H., Lovell, N. H., & Tzeng, Y. (2011) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01407.2010 · Cited by 50
“THE WINDKESSEL is an important component of many cardiovascular models and has been widely adopted in the study of arterial hemodynamics (2, 4, 26, 27, 38).”
BackgroundMethodInfluentialThe Contribution of Vascular Smooth Muscle to Aortic Stiffness Across Length Scales
Saphirstein, R. J., & Morgan, K. G. (2013) · Microcirculation · doi:10.1111/micc.12101 · Cited by 31
“Another surrogate for material stiffness is aortic characteristic impedance Zc, a measure of the vessel’s capacity for limiting the flow induced by a time-varying pressure gradient [2,40].”
Background
Metadata
- Authors
- Avolio, A.
- Affiliations
- Macquarie University (AU)
- Corresponding author
- Avolio, Alberto
- ORCID
- Avolio, Alberto
- Venue
- Medical & Biological Engineering & Computing
- Published
- 2008-10-24
- Volume
- 47
- Issue
- 2
- Pages
- 143-151
- ISSN
- 0140-0118 (ISSN-L)
- 1741-0444
- OpenAlex
- W2058459821
- Cited by
- 26
- References
- 50
- Citations by year
- 2026: 1 · 2022: 1 · 2020: 2 · 2017: 2 · 2016: 1 · 2015: 2 · 2014: 1 · 2013: 5 · 2012: 2
- FWCI
- 0.45
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Medical & Biological Engineering & Computing (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
- Keywords
- vascular impedance, impedance spectra, arterial hemodynamics, systemic vascular resistance, optimal design, body size scaling, pressure-flow relationship
- MeSH terms
- Animals, Arteries, Hemodynamics, Humans, Models, Cardiovascular, Vascular Resistance, Body Size
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Input impedance of distributed arterial structures as used in investigations of underlying concepts in arterial haemodynamics. https://app.cochat.ai/papers/10.1007/s11517-008-0413-0
- The paper
- Avolio, A. (2009). Input impedance of distributed arterial structures as used in investigations of underlying concepts in arterial haemodynamics. Medical & Biological Engineering & Computing. https://doi.org/10.1007/s11517-008-0413-0
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.