The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
A real-time system for biomechanical analysis of human movement and muscle function
Open accessAbstract
Mechanical analysis of movement plays an important role in clinical management of neurological and orthopedic conditions. There has been increasing interest in performing movement analysis in real-time, to provide immediate feedback to both therapist and patient. However, such work to date has been limited to single-joint kinematics and kinetics. Here we present a software system, named human body model (HBM), to compute joint kinematics and kinetics for a full body model with 44 degrees of freedom, in real-time, and to estimate length changes and forces in 300 muscle elements. HBM was used to analyze lower extremity function during gait in 12 able-bodied subjects. Processing speed exceeded 120 samples per second on standard PC hardware. Joint angles and moments were consistent within the group, and consistent with other studies in the literature. Estimated muscle force patterns were consistent among subjects and agreed qualitatively with electromyography, to the extent that can be expected from a biomechanical model. The real-time analysis was integrated into the D-Flow system for development of custom real-time feedback applications and into the gait real-time analysis interactive lab system for gait analysis and gait retraining.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Figures



![Fig. 4 The top two rows show lower extremity joint angles and moments obtained with the human body model (HBM) from the 12 able-bodied subjects walking at preferred speed. Each curve represents one subject’s mean gait cycle. The shaded area represents mean and standard deviation from a study on children [24], for those variables that were available. Other joint-related variables are available in HBM, but not shown: joint angular velocity, and joint power generation. The bottom two rows show the inter-segmental loads at the knee, acting on the shank segment, and expressed using the axes of the shank reference frame: X (anterior), Y (lateral), and Z (superior)](/paper-figures/d8ebdcb25d9443e6a9519640a9ed59a7/a-real-time-system-for-biomechanical-analysis-of-human-movement-and-muscle-figure-4.jpg)
![Fig. 5 Forces and length changes for 16 muscle groups. EMG patterns from the literature [31] are shown for comparison, with the area under the EMG-time curve shaded. Amplitudes of the EMG patterns were scaled to coincide with the amplitude of estimated muscle force. Other muscle-related variables are available in HBM, but not shown: velocity of length change, power generation, and muscle activation (F/F max)](/paper-figures/5fd7dbcf08f54ba98965ed43e5f6ea51/a-real-time-system-for-biomechanical-analysis-of-human-movement-and-muscle-figure-5.jpg)
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Numerical Recipes, The Art of Scientific Computing
Press, W. H., Flannery, B. P., Teukolsky, S. A., Vetterling, W. T., & Gould, H. (1987) · American Journal of Physics · doi:10.1119/1.14981 · Cited by 10,032
OpenSim: Open-Source Software to Create and Analyze Dynamic Simulations of Movement
Delp, S. L., Anderson, F. C., Arnold, A. S., Loan, P., Habib, A., John, C. T., Guendelman, E., & Thelen, D. G. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.901024 · Cited by 4,951
Numerical Recipes--The Art of Scientific Computing.
Fritsch, F. N., Press, W. H., Flannery, B. P., Teukolsky, S. A., & Vetterling, W. T. (1988) · Mathematics of Computation · doi:10.2307/2007938 · Cited by 4,846
Hewett, T. E., Myer, G. D., Ford, K. R., Heidt, R. S., Colosimo, A. J., McLean, S. G., van den Bogert, A. J., Paterno, M. V., & Succop, P. (2005) · The American Journal of Sports Medicine · doi:10.1177/0363546504269591 · Cited by 3,577
Adjustments to Zatsiorsky-Seluyanov's segment inertia parameters
de Leva, P. (1996) · Journal of Biomechanics · doi:10.1016/0021-9290(95)00178-6 · Cited by 3,072
An interactive graphics-based model of the lower extremity to study orthopaedic surgical procedures
Delp, S. L., Loan, J. P., Hoy, M. G., Zajac, F. E., Topp, E. L., & Rosen, J. M. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.102791 · Cited by 2,003
Repeatability of kinematic, kinetic, and electromyographic data in normal adult gait
Kadaba, M. P., Ramakrishnan, H. K., Wootten, M. E., Gainey, J., Gorton, G. E., & Cochran, G. V. B. (1989) · Journal of Orthopaedic Research® · doi:10.1002/jor.1100070611 · Cited by 1,479
A physiologically based criterion of muscle force prediction in locomotion
Crowninshield, R. D., & Brand, R. A. (1981) · Journal of Biomechanics · doi:10.1016/0021-9290(81)90035-x · Cited by 1,434
Model-based estimation of muscle forces exerted during movements
Erdemir, A., McLean, S. G., Herzog, W., & van den Bogert, A. J. (2006) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2006.09.005 · Cited by 873
EMG profiles during normal human walking: stride-to-stride and inter-subject variability
Winter, D. A., & Yack, H. J. (1987) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(87)90003-4 · Cited by 681
Research works printed but not linked: 2
- Rasmussen J, de Zee M, Dahl J, Damsgaard M (2009) Salient properties of a combined minimum-fatigue and and quadratic muscle recruitment criterion. In: Proceedings of the 12th international symposium on computer simulation in biomechanics, Cape Town, South Africa, 2–4 July 2009
- van den Bogert AJ, Geijtenbeek T A state space filter for smoothing and differentiation of real-time data with variable sampling rate. Comput Methods Biomech Biomed Eng (in review)
Cited by
Sorted by citations
Items 101–200 of 391
Ground Reaction Force Estimation in Prosthetic Legs With Nonlinear Kalman Filtering Methods
Fakoorian, S. A., Azimi, V., Moosavi, M., Richter, H., & Simon, D. (2017) · Journal of Dynamic Systems Measurement and Control · doi:10.1115/1.4036546 · Cited by 23
Rosenfeldt, A. B., Penko, A. L., Streicher, M. C., Zimmerman, N. M., Koop, M. M., & Alberts, J. L. (2019) · Parkinsonism & Related Disorders · doi:10.1016/j.parkreldis.2019.05.021 · Cited by 23
A novel flexible wearable sensor for estimating joint-angles
Lee, S. I., Daneault, J., Weydert, L., & Bonato, P. (2016) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn.2016.7516291 · Cited by 22
Robust Adaptive Impedance Control With Application to a Transfemoral Prosthesis and Test Robot
Azimi, V., Fakoorian, S. A., Nguyen, T. T., & Simon, D. (2018) · Journal of Dynamic Systems Measurement and Control · doi:10.1115/1.4040463 · Cited by 22
Bahadori, S., Williams, J. M., Collard, S. S., & Swain, I. (2023) · Cyborg and Bionic Systems · doi:10.34133/cbsystems.0069 · Cited by 22
Schwartz, M., & Dixon, P. C. (2018) · PLoS ONE · doi:10.1371/journal.pone.0189984 · Cited by 21
Effects of Pulmonary Rehabilitation on Gait Characteristics in Patients with COPD
Liu, W.-Y., Meijer, K., Delbressine, J. M., Willems, P. J. B., Wouters, E. F. �., & Spruit, M. A. (2019) · Journal of Clinical Medicine · doi:10.3390/jcm8040459 · Cited by 23
Kernozek, T. W., Schiller, M., Rutherford, D. N., Smith, A., Durall, C. J., & Almonroeder, T. G. (2020) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2020.105050 · Cited by 21
Achilles Tendon Loading During Heel-Raising and -Lowering Exercises
Revak, A., Diers, K., Kernozek, T. W., Gheidi, N., & Olbrantz, C. (2017) · Journal of Athletic Training · doi:10.4085/1062-6050-52.1.04 · Cited by 21
Hooren, B. V., van Rengs, L., & Meijer, K. (2024) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000003493 · Cited by 21
Patellar tendon stress between two variations of the forward step lunge
Zellmer, M., Kernozek, T. W., Gheidi, N., Hove, J., & Torry, M. R. (2017) · Journal of sport and health science/Journal of Sport and Health Science · doi:10.1016/j.jshs.2016.12.005 · Cited by 22
Perspectives on Sharing Models and Related Resources in Computational Biomechanics Research
Erdemir, A., Hunter, P. J., Holzapfel, G. A., Loew, L. M., Middleton, J., Jacobs, C. R., Nithiarasu, P., Löhner, R., Wei, G., Winkelstein, B. A., et al. (2017) · Journal of Biomechanical Engineering · doi:10.1115/1.4038768 · Cited by 20
Alberts, J. L., Kaya, R. D., Penko, A. L., Streicher, M. C., Zimmerman, E. M., Davidson, S., Walter, B. L., & Rosenfeldt, A. B. (2023) · Neurorehabilitation and neural repair · doi:10.1177/15459683231184190 · Cited by 22
Shen, Q., Huang, W., Qiu, Y., Wang, S., Zhang, B., Sun, N.-N., & Zhou, Q. (2023) · Biomedicine & Pharmacotherapy · doi:10.1016/j.biopha.2023.115525 · Cited by 19
Yamamoto, M., Shimatani, K., Hasegawa, M., & Kurita, Y. (2019) · ROBOMECH Journal · doi:10.1186/s40648-019-0137-y · Cited by 19
The effect of changing mediolateral center of pressure on rearfoot eversion during treadmill running
Mousavi, S. H., van Kouwenhove, L., Rajabi, R., Zwerver, J., & Hijmans, J. M. (2020) · Gait & Posture · doi:10.1016/j.gaitpost.2020.10.032 · Cited by 19
Achilles tendon loading during weight bearing exercises
Gheidi, N., Kernozek, T. W., Willson, J. D., Revak, A., & Diers, K. (2018) · Physical Therapy in Sport · doi:10.1016/j.ptsp.2018.05.007 · Cited by 19
Inertial compensation for belt acceleration in an instrumented treadmill
Hnat, S. K., & van den Bogert, A. J. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.10.014 · Cited by 18
Punt, M., Bruijn, S. M., Wittink, H. M., van de Port, I. G. L., Wubbels, G., & van Dieën, J. H. (2017) · Gait & Posture · doi:10.1016/j.gaitpost.2017.09.013 · Cited by 18
Patellofemoral joint loading during the forward and backward lunge
Goulette, D., Griffith, P., Schiller, M., Rutherford, D. N., & Kernozek, T. W. (2020) · Physical Therapy in Sport · doi:10.1016/j.ptsp.2020.12.001 · Cited by 18
Predictive simulation of post-stroke gait with functional electrical stimulation
Santos, G. F., Jakubowitz, E., Pronost, N., Bonis, T., & Hurschler, C. (2021) · Scientific Reports · doi:10.1038/s41598-021-00658-z · Cited by 18
Manipulation of visual biofeedback during gait with a time delayed adaptive Virtual Mirror Box
Barton, G., Asha, A. R. D., Loon, E. C. P. V., Geijtenbeek, T., & Robinson, M. A. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-101 · Cited by 18
Self-citationSex differences in gluteal muscle forces during running
Vannatta, C. N., & Kernozek, T. W. (2018) · Sports Biomechanics · doi:10.1080/14763141.2018.1548641 · Cited by 18
Scalona, E., Marco, R. D., Castelli, E., Desloovere, K., van der Krogt, M. M., Cappa, P., & Rossi, S. (2019) · International Biomechanics · doi:10.1080/23335432.2019.1621205 · Cited by 18
Moll, I., Marcellis, R. G. J., Coenen, M. L. P., Fleuren, S. M., Willems, P. J. B., Speth, L. A. W. M., Witlox, A. M. A., Meijer, K., & Vermeulen, R. J. (2022) · BMC Pediatrics · doi:10.1186/s12887-021-03037-9 · Cited by 19
Ren, X., Lutter, C., Kebbach, M., Bruhn, S., Yang, Q., Bader, R., & Tischer, T. (2022) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2022.893840 · Cited by 18
Barefoot walking is more stable in the gait of balance recovery in older adults
Ren, X., Kebbach, M., Bruhn, S., Yang, Q., Lin, H., Bader, R., Tischer, T., & Lutter, C. (2022) · BMC Geriatrics · doi:10.1186/s12877-022-03628-w · Cited by 17
Dasgupta, A., Sharma, R., Mishra, C., & Nagaraja, V. H. (2023) · Bioengineering · doi:10.3390/bioengineering10050510 · Cited by 18
Ren, X., Lutter, C., Kebbach, M., Bruhn, S., Bader, R., & Tischer, T. (2022) · BMC Geriatrics · doi:10.1186/s12877-022-03354-3 · Cited by 17
Bahadori, S., Williams, J. M., & Wainwright, T. W. (2020) · Data in Brief · doi:10.1016/j.dib.2020.106613 · Cited by 16
Hooren, B. V., Copier, R., Pedersen, S., Balamouti, Z., & Meijer, K. (2025) · Scandinavian Journal of Medicine and Science in Sports · doi:10.1111/sms.70087 · Cited by 15
Zonnino, A., Smith, D. R., Delgorio, P. L., Johnson, C. L., & Sergi, F. (2019) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2019.8779562 · Cited by 15
Muscle‐Based Control for Character Animation
Ruiz, A. L. C., Pontonnier, C., Pronost, N., & Dumont, G. (2016) · Computer Graphics Forum · doi:10.1111/cgf.12863 · Cited by 15
Exoskeletons, Exomusculatures, Exosuits: Dynamic Modeling and Simulation
Arslan, Y. Z., Karabulut, D., Örteş, F., & Popović, M. B. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-812939-5.00011-2 · Cited by 14
Effects of functional power training on gait kinematics in children with cerebral palsy
Oudenhoven, L. M., van Vulpen, L. F., Dallmeijer, A. J., de Groot, S., Buizer, A. I., & van der Krogt, M. M. (2019) · Gait & Posture · doi:10.1016/j.gaitpost.2019.06.023 · Cited by 14
Parkinson’s gait kinematics deteriorates across multiple cognitive domains under dual-task paradigms
Penko, A. L., Streicher, M. C., Dey, T., Rosenfeldt, A. B., & Alberts, J. L. (2020) · Clinical Neurology and Neurosurgery · doi:10.1016/j.clineuro.2020.106083 · Cited by 14
Sikidar, A., & Kalyanasundaram, D. (2019) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2019.05.021 · Cited by 14
Amaefule, C. O., Lüdtke, S., Kirste, T., & Teipel, S. J. (2020) · JMIR Serious Games · doi:10.2196/18455 · Cited by 14
Senden, R. H. J., Marcellis, R. G. J., Willems, P. J. B., Witlox, A. M. A., & Meijer, K. (2024) · Data in Brief · doi:10.1016/j.dib.2024.110230 · Cited by 14
Heinrich, D., van den Bogert, A. J., & Nachbauer, W. (2022) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2022.894568 · Cited by 13
The validity and usability of an eight marker model for avatar-based biofeedback gait training
Booth, A., van der Krogt, M. M., Buizer, A. I., Steenbrink, F., & Harlaar, J. (2019) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2019.08.013 · Cited by 13
Self-citationEffect of different forefoot rocker radii on lower-limb joint biomechanics in healthy individuals
van Kouwenhove, L., Verkerke, G. J., Klaas Postema, A., Dekker, R., & Hijmans, J. M. (2021) · Gait & Posture · doi:10.1016/j.gaitpost.2021.03.008 · Cited by 13
Theunissen, K., Hooren, B. V., Plasqui, G., & Meijer, K. (2021) · Gait & Posture · doi:10.1016/j.gaitpost.2021.11.005 · Cited by 13
Machine Learning for Musculoskeletal Modeling of Upper Extremity
Sharma, R., Dasgupta, A., Cheng, R., Mishra, C., & Nagaraja, V. H. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3197461 · Cited by 13
Wireless Epidermal Six-Axis Inertial Measurement Units for Real-Time Joint Angle Estimation
Lee, J. K., Han, S. J., Kim, K., Kim, Y. H., & Lee, S. (2020) · Applied Sciences · doi:10.3390/app10072240 · Cited by 13
Model-based estimation of muscle and ACL forces during turning maneuvers in alpine skiing
Heinrich, D., van den Bogert, A. J., Mössner, M., & Nachbauer, W. (2023) · Scientific Reports · doi:10.1038/s41598-023-35775-4 · Cited by 12
Hawley, S. J., Hamilton-Wright, A., & Fischer, S. L. (2022) · Ergonomics · doi:10.1080/00140139.2022.2061052 · Cited by 12
Livet, C., Rouvier, T., Sauret, C., Pillet, H., Dumont, G., & Pontonnier, C. (2022) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2022.2093607 · Cited by 12
Escriche-Escuder, A., Cuesta‐Vargas, A., & Casaña, J. (2022) · BMJ Open · doi:10.1136/bmjopen-2021-057605 · Cited by 12
Changes in gluteal muscle forces with alteration of footstrike pattern during running
Vannatta, C. N., Kernozek, T. W., & Gheidi, N. (2017) · Gait & Posture · doi:10.1016/j.gaitpost.2017.08.005 · Cited by 12
Wodarski, P., Jurkojć, J., Bieniek, A., Chrzan, M., Michnik, R., Polechoński, J., & Gzik, M. (2019) · Advances in intelligent systems and computing · doi:10.1007/978-3-030-23762-2_48 · Cited by 12
Mirzaei, N. M., Changizi, N., Asadpoure, A., Su, S., Sofia, D., Tatárová, Z., Zervantonakis, I. K., Chang, Y. H., & Shahriyari, L. (2022) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1009953 · Cited by 14
Mahdian, Z. S., Wang, H., Refai, M. I. M., Durandau, G., Sartori, M., & MacLean, M. K. (2023) · Journal of Applied Biomechanics · doi:10.1123/jab.2023-0046 · Cited by 11
Center of Mass Estimation for Impaired Gait Assessment Using Inertial Measurement Units
Labrozzi, G. C., Warner, H., Makowski, N. S., Audu, M. L., & Triolo, R. J. (2023) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2023.3341436 · Cited by 11
Edriss, S., Romagnoli, C., Maurizi, M., Caprioli, L., Bonaiuto, V., & Annino, G. (2025) · Journal of Sports Sciences · doi:10.1080/02640414.2025.2524283 · Cited by 11
Compensation for inertial and gravity effects in a moving force platform
Hnat, S. K., van Basten, B. J. H., & van den Bogert, A. J. (2018) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2018.05.009 · Cited by 11
Rodriguez, M. W., Menhennett, S. A., Vannatta, C. N., & Kernozek, T. W. (2020) · Physical Therapy in Sport · doi:10.1016/j.ptsp.2020.06.009 · Cited by 11
Oudenhoven, L. M., Kerkum, Y. L., Buizer, A. I., & van der Krogt, M. M. (2021) · Disability and Rehabilitation · doi:10.1080/09638288.2021.1970829 · Cited by 11
Lower limb muscle fatigue after uphill walking in children with unilateral spastic cerebral palsy
Moll, I., Essers, J. M. N. H., Marcellis, R. G. J., Senden, R. H. J., Janssen‐Potten, Y., Vermeulen, R. J., & Meijer, K. (2022) · PLoS ONE · doi:10.1371/journal.pone.0278657 · Cited by 13
Lavikainen, J., Vartiainen, P., Stenroth, L., & Karjalainen, P. A. (2023) · PeerJ · doi:10.7717/peerj.15097 · Cited by 11
Ankle Moment Estimation Based on A Novel Distributed Plantar Pressure Sensing System
Du, M., Lv, B., Fan, B., Li, X., Yu, J., Yi, F., Liu, T., & Cai, S. (2024) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2024.3444818 · Cited by 11
Lansink, I. L. B. O., van Kouwenhove, L., Dijkstra, P., Klaas Postema, A., & Hijmans, J. M. (2017) · Gait & Posture · doi:10.1016/j.gaitpost.2017.07.040 · Cited by 11
EFFECT OF HEEL LIFTS ON PATELLOFEMORAL JOINT STRESS DURING RUNNING
Mestelle, Z., Kernozek, T. W., Adkins, K. S., Miller, J., & Gheidi, N. (2017) · International Journal of Sports Physical Therapy · doi:10.26603/ijspt20170711 · Cited by 11
Adaptive smartphone-based sensor fusion for estimating competitive rowing kinematic metrics
Cloud, B., Tarien, B., Liu, A., Shedd, T., Lin, X., Hubbard, M., Crawford, R. P., & Moore, J. K. (2019) · PLoS ONE · doi:10.1371/journal.pone.0225690 · Cited by 11
Flux, E., Bar‐On, L., Buizer, A. I., Harlaar, J., & van der Krogt, M. M. (2023) · Gait & Posture · doi:10.1016/j.gaitpost.2023.02.012 · Cited by 10
Predicting Gait Patterns of Children With Spasticity by Simulating Hyperreflexia
Veerkamp, K., Carty, C. P., Waterval, N. F. J., Geijtenbeek, T., Buizer, A. I., Lloyd, D. G., Harlaar, J., & van der Krogt, M. M. (2023) · Journal of Applied Biomechanics · doi:10.1123/jab.2023-0022 · Cited by 10
Self-citationThe Influence of Motion Data Low-Pass Filtering Methods in Machine-Learning Models
Wang, S., Pitts, J., Purohit, R., & Shah, H. (2025) · Applied Sciences · doi:10.3390/app15042177 · Cited by 10
MATLAB-based tools for automated processing of motion tracking data provided by the GRAIL
Feldhege, F., Richter, K., Bruhn, S., Fischer, D., & Mittlmeier, T. (2021) · Gait & Posture · doi:10.1016/j.gaitpost.2021.09.179 · Cited by 10
Which lower limb joints compensate for destabilizing energy during walking in humans?
Golyski, P. R., & Sawicki, G. S. (2022) · Journal of The Royal Society Interface · doi:10.1098/rsif.2022.0024 · Cited by 10
Fallahtafti, F., Bruijn, S. M., Gonabadi, A. M., Sangtarashan, M., Boron, J. B., Curtze, C., Siu, K., Myers, S. A., & Yentes, J. M. (2023) · Sensors · doi:10.3390/s23052833 · Cited by 10
Geiger, F., Kebbach, M., Vogel, D., Weißmann, V., & Bader, R. (2023) · Applied Sciences · doi:10.3390/app13063854 · Cited by 10
Alterations in Achilles tendon stress and strain across a range of running velocities
Ertman, B., Klaeser, M., Voie, L., Gheidi, N., Vannatta, C. N., Rutherford, D. N., & Kernozek, T. W. (2023) · Journal of Sports Sciences · doi:10.1080/02640414.2023.2225015 · Cited by 10
Moving Horizon Estimation of Human Kinematics and Muscle Forces
Ceglia, A., Bailly, F., & Begon, M. (2023) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2023.3291921 · Cited by 10
Perrone, M., Guidetti, M., Galli, M., Nho, S. J., Wimmer, M. A., & Malloy, P. J. (2023) · Journal of Orthopaedic Research® · doi:10.1002/jor.25744 · Cited by 10
A practical computer based vision system for posture and movement sensing in occupational medicine
Marfia, G., & Roccetti, M. (2016) · Multimedia Tools and Applications · doi:10.1007/s11042-016-3469-0 · Cited by 10
Patellofemoral Joint Stress during Running with Added Load in Females
Kujawa, M., Goerlitz, A., Rutherford, D. N., & Kernozek, T. W. (2020) · International Journal of Sports Medicine · doi:10.1055/a-1088-5467 · Cited by 10
Chen, S., Peng, C., Yang, B., Lin, J., Zhou, L., Jiang, Z., Liu, Z., Liu, Y., & Tang, L. (2026) · npj Artificial Intelligence · doi:10.1038/s44387-026-00083-5 · Cited by 9
Kinematic and muscle force asymmetry in healthy runners: How do different methods measure up?
Vannatta, C. N., Blackman, T., & Kernozek, T. W. (2023) · Gait & Posture · doi:10.1016/j.gaitpost.2023.05.010 · Cited by 9
Tankink, T., Houdijk, H., & Hijmans, J. M. (2024) · European Journal of Sport Science · doi:10.1002/ejsc.12054 · Cited by 9
Alarifi, S., Herrington, L. C., Althomali, O. W., Alenezi, F., Sheeha, B. H. B., & Jones, R. K. (2025) · Orthopaedic Journal of Sports Medicine · doi:10.1177/23259671251340302 · Cited by 9
Flux, E., van der Krogt, M. M., Harlaar, J., Buizer, A. I., & Sloot, L. H. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00940-1 · Cited by 9
Bahadori, S., Middleton, R., & Wainwright, T. W. (2022) · Healthcare · doi:10.3390/healthcare10102018 · Cited by 9
Do Older Adults Select Appropriate Motor Strategies in a Stepping-Down Paradigm?
Kluft, N., Bruijn, S. M., van Dieën, J. H., & Pijnappels, M. A. G. M. (2018) · Frontiers in Physiology · doi:10.3389/fphys.2018.01419 · Cited by 9
Fakoorian, S. A., Roshanineshat, A., Khalaf, P., Azimi, V., Simon, D., & Hardin, E. C. (2020) · Applied Bionics and Biomechanics · doi:10.1155/2020/8864854 · Cited by 9
Self-citationWarner, H., Khalaf, P., Richter, H., Simon, D., Hardin, E. C., & van den Bogert, A. J. (2021) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2021.103744 · Cited by 9
Self-citationSenden, R. H. J., Marcellis, R. G. J., Meijer, K., Willems, P. J. B., Lenssen, A. F., Staal, H. M., Janssen‐Potten, Y., Groen, V., Vermeulen, R. J., & Witlox, A. M. A. (2022) · PeerJ · doi:10.7717/peerj.13752 · Cited by 9
Neural Networks for Muscle Forces Prediction in Cycling
Cecchini, G., Lozito, G. M., Schmid, M., Conforto, S., Fulginei, F. R., & Bibbo, D. (2014) · Algorithms · doi:10.3390/a7040621 · Cited by 9
A Multi-body Simulation Framework for Live Motion Tracking and Analysis within the Unity Environment
Abella, J., & Demircan, E. (2019) · International Conference on Ubiquitous Robots (UR) · doi:10.1109/urai.2019.8768659 · Cited by 9
Chincisan, A., Tecante, K. E., Becker, M., Magnenat‐Thalmann, N., Hurschler, C., & Choi, H. F. (2015) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-015-1251-9 · Cited by 9
Measuring biomechanical loads in team sports – from lab to fieldPreprint
Verheul, J., Nedergaard, N. J., Vanrenterghem, J., & Robinson, M. A. (2019) · SportRxiv (OSF Preprints) · doi:10.31236/osf.io/5pt3y · Cited by 9
Hooren, B. V., & Meijer, K. (2024) · Data in Brief · doi:10.1016/j.dib.2024.110312 · Cited by 9
Oehme, S., Milinkovic, D. D., Paolucci, A., Krafzick, S., Fahy, S., Damm, P., Winkler, T., Jung, T. I., & Bartek, B. (2025) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1002/ksa.12605 · Cited by 8
Muscle Moment Arm–Joint Angle Relations in the Hip, Knee, and Ankle: A Visualization of Datasets
Chen, Z., & Franklin, D. W. (2025) · Annals of Biomedical Engineering · doi:10.1007/s10439-025-03735-w · Cited by 8
Benchmarking the predictive capability of human gait simulations
Afschrift, M., Kistemaker, D. A., Bobbert, M. F., & Groote, F. D. (2025) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1012713 · Cited by 11
Dynamic alignment using external socket reaction moments in trans-tibial amputees
Jonkergouw, N., Prins, M. R., van der Wurff, P., Gijsbers, J., Houdijk, H., & Buis, A. W. P. (2018) · Gait & Posture · doi:10.1016/j.gaitpost.2018.11.004 · Cited by 8
Hooren, B. V., Willems, P. J. B., Plasqui, G., & Meijer, K. (2024) · Scandinavian Journal of Medicine and Science in Sports · doi:10.1111/sms.14565 · Cited by 8
Lopes, J. M., Figueiredo, J., Pinheiro, C., Reis, L. P., & Santos, C. P. (2021) · Journal of Intelligent & Robotic Systems · doi:10.1007/s10846-021-01423-0 · Cited by 8
The Effects of Wobbling Mass Components on Joint Dynamics During Running
Masters, S. E., & Challis, J. H. (2022) · Journal of Applied Biomechanics · doi:10.1123/jab.2021-0051 · Cited by 8
Mooijekind, B., Flux, E., Buizer, A. I., van der Krogt, M. M., & Bar‐On, L. (2023) · Gait & Posture · doi:10.1016/j.gaitpost.2023.02.007 · Cited by 8
A Real-Time Control System of Upper-Limb Human Musculoskeletal Model With Environmental Integration
Saputra, A. A., Chin, W. H., Matsuda, T., & Kubota, N. (2023) · IEEE Access · doi:10.1109/access.2023.3296100 · Cited by 8
Metadata
- Authors
- van den Bogert, A. J., Geijtenbeek, T., Even-Zohar, O., Steenbrink, F., & Hardin, E. C.
- Affiliations
- Louis Stokes Cleveland VA Medical Center (US)
- Venue
- Medical & Biological Engineering & Computing
- Published
- 2013-07-25
- Volume
- 51
- Issue
- 10
- Pages
- 1069-1077
- ISSN
- 0140-0118 (ISSN-L)
- 1741-0444
- PMC
- PMC3751375
- OpenAlex
- W2050578981
- Cited by
- 392
- References
- 32
- Citations by year
- 2026: 20 · 2025: 31 · 2024: 30 · 2023: 49 · 2022: 38 · 2021: 42 · 2020: 34 · 2019: 35 · 2018: 32 · 2017: 35 · 2016: 17 · 2015: 17 · 2014: 10 · 2013: 2
- FWCI
- 8.43
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Locations
- Medical & Biological Engineering & Computing (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- EngagedScholarship @ Cleveland State University (Cleveland State University) (submittedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Physical Sciences › Engineering › Biomedical Engineering › Lower Extremity Biomechanics and Pathologies
- Physical Sciences › Computer Science › Computer Graphics and Computer-Aided Design › Human Motion and Animation
- Keywords
- human body model, joint kinematics, joint kinetics, muscle force estimation, gait analysis, lower extremity, real-time feedback, gait retraining, electromyography validation
- MeSH terms
- Adult, Biomechanical Phenomena, Computer Simulation, Computer Systems, Female, Gait, Humans, Male, Models, Biological, Movement, Software, User-Computer Interface, Range of Motion, Articular, Muscle, Skeletal
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review