CoChat

Automatic 3D liver location and segmentation via convolutional neural network and graph cut

Lu, Fang, Wu, Fa, Hu, Peijun, Peng, Zhiyi, Kong, Dexing · 2017 · International Journal of Computer Assisted Radiology and Surgery

The DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.

Abstract

Purpose Segmentation of the liver from abdominal computed tomography (CT) images is an essential step in some computer-assisted clinical interventions, such as surgery planning for living donor liver transplant, radiotherapy and volume measurement. In this work, we develop a deep learning algorithm with graph cut refinement to automatically segment the liver in CT scans.Methods The proposed method consists of two main steps: (i) simultaneously liver detection and probabilistic segmentation using 3D convolutional neural network; (ii) accuracy refinement of the initial segmentation with graph cut and the previously learned probability map.Results The proposed approach was validated on forty CT volumes taken from two public databases MICCAI-Sliver07 and 3Dircadb1. For the MICCAI-Sliver07 test dataset, the calculated mean ratios of volumetric overlap error (VOE), relative volume difference (RVD), average symmetric surface distance (ASD), root-mean-square symmetric surface distance (RMSD) and maximum symmetric surface distance (MSD) are 5.9, 2.7 %, 0.91, 1.88 and 18.94 mm, respectively. For the 3Dircadb1 dataset, the calculated mean ratios of VOE, RVD, ASD, RMSD and MSD are 9.36, 0.97 %, 1.89, 4.15 and 33.14 mm, respectively.Conclusions The proposed method is fully automatic without any user interaction. Quantitative results reveal that the proposed approach is efficient and accurate for hepatic volume estimation in a clinical setup. The high correlation between the automatic and manual references shows that the proposed method can be good enough to replace the time-consuming and nonreproducible manual segmentation method.

Overview

Integrity signals

Registry

Crossref · 10.1007/s11548-016-1467-3

Cites

45 of 45 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Research works printed but not linked: 3

  1. Heimann T, Meinzer HP, Wolf I (2007) A statistical deformable model for the segmentation of liver CT volumes. In: Miccai workshop on 3D segmentation in the clinic, pp 161–166
  2. Kainmüller D, Lange T, Lamecker H (2007) Shape constrained automatic segmentation of the liver based on a heuristic intensity model. In: Proceeding MICCAI workshop 3-D segmentat. Clinic: a gand challenge, pp 109–116
  3. Kinda A, Saddi Rousson M, Hotel CC, Cheriet F (2007) Global to local shape matching for liver segmentation in CT imaging. In: Miccai workshop on 3D segmentation in the clinic, pp 207–214

Cited by

See all 285

Metadata

Authors
Lu, F., Wu, F., Hu, P., Peng, Z., & Kong, D.
Affiliations
  • Zhejiang University (CN)
  • First Affiliated Hospital Zhejiang University (CN)
Venue
International Journal of Computer Assisted Radiology and Surgery
Published
2016-09-07
Volume
12
Issue
2
Pages
171-182
ISSN
  • 1861-6410 (ISSN-L)
  • 1861-6429
OpenAlex
W2357815549
Cited by
284
References
45
Citations by year
2026: 5 · 2025: 10 · 2024: 16 · 2023: 24 · 2022: 48 · 2021: 52 · 2020: 35 · 2019: 45 · 2018: 33 · 2017: 12 · 2016: 3
FWCI
21.06
Type
journal article
Language
en
Open access
closed
Locations
  • International Journal of Computer Assisted Radiology and Surgery (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
  • Physical Sciences › Engineering › Biomedical Engineering › Medical Imaging and Analysis
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Advanced Neural Network Applications
Keywords
liver segmentation, abdominal CT, 3D convolutional neural networks, automatic segmentation
MeSH terms
Abdomen, Algorithms, Humans, Liver, Organ Size, Tomography, X-Ray Computed, Databases, Factual, Neural Networks, Computer, Imaging, Three-Dimensional

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.