CoChat

Active learning using deep Bayesian networks for surgical workflow analysis

Open access
Bodenstedt, Sebastian, Rivoir, Dominik, Jenke, Alexander, Wagner, Martin, Breucha, Michael, Müller-Stich, Beat, Mees, Sören Torge, Weitz, Jürgen, Speidel, Stefanie · 2019 · International Journal of Computer Assisted Radiology and Surgery
Cited by 58

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

PurposeFor many applications in the field of computer-assisted surgery, such as providing the position of a tumor, specifying the most probable tool required next by the surgeon or determining the remaining duration of surgery, methods for surgical workflow analysis are a prerequisite. Often machine learning-based approaches serve as basis for analyzing the surgical workflow. In general, machine learning algorithms, such as convolutional neural networks (CNN), require large amounts of labeled data. While data is often available in abundance, many tasks in surgical workflow analysis need annotations by domain experts, making it difficult to obtain a sufficient amount of annotations.MethodsThe aim of using active learning to train a machine learning model is to reduce the annotation effort. Active learning methods determine which unlabeled data points would provide the most information according to some metric, such as prediction uncertainty. Experts will then be asked to only annotate these data points. The model is then retrained with the new data and used to select further data for annotation. Recently, active learning has been applied to CNN by means of deep Bayesian networks (DBN). These networks make it possible to assign uncertainties to predictions. In this paper, we present a DBN-based active learning approach adapted for image-based surgical workflow analysis task. Furthermore, by using a recurrent architecture, we extend this network to video-based surgical workflow analysis. To decide which data points should be labeled next, we explore and compare different metrics for expressing uncertainty.ResultsWe evaluate these approaches and compare different metrics on the Cholec80 dataset by performing instrument presence detection and surgical phase segmentation. Here we are able to show that using a DBN-based active learning approach for selecting what data points to annotate next can significantly outperform a baseline based on randomly selecting data points. In particular, metrics such as entropy and variation ratio perform consistently on the different tasks.ConclusionWe show that using DBN-based active learning strategies make it possible to selectively annotate data, thereby reducing the required amount of labeled training in surgical workflow-related tasks.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s11548-019-01963-9

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 58

Metadata

Authors
Bodenstedt, S., Rivoir, D., Jenke, A., Wagner, M., Breucha, M., Müller-Stich, B., Mees, S. T., Weitz, J., & Speidel, S.
Venue
International Journal of Computer Assisted Radiology and Surgery
Published
2019-04-09
Volume
14
Issue
6
Pages
1079-1087
ISSN
  • 1861-6410 (ISSN-L)
  • 1861-6429
OpenAlex
W2899763763
Cited by
58
References
7
FWCI
6.48
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Active learning using deep Bayesian networks for surgical workflow analysis. https://app.cochat.ai/papers/10.1007/s11548-019-01963-9
The paper
Bodenstedt, S., Rivoir, D., Jenke, A., Wagner, M., Breucha, M., Müller-Stich, B., Mees, S. T., Weitz, J., & Speidel, S. (2019). Active learning using deep Bayesian networks for surgical workflow analysis. International Journal of Computer Assisted Radiology and Surgery. https://doi.org/10.1007/s11548-019-01963-9

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.