Preliminary assessment of automated radiology report generation with generative pre-trained transformers: comparing results to radiologist-generated reports
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Purpose: In this preliminary study, we aimed to evaluate the potential of the generative pre-trained transformer (GPT) series for generating radiology reports from concise imaging findings and compare its performance with radiologist-generated reports. Methods: This retrospective study involved 28 patients who underwent computed tomography (CT) scans and had a diagnosed disease with typical imaging findings. Radiology reports were generated using GPT-2, GPT-3.5, and GPT-4 based on the patient’s age, gender, disease site, and imaging findings. We calculated the top-1, top-5 accuracy, and mean average precision (MAP) of differential diagnoses for GPT-2, GPT-3.5, GPT-4, and radiologists. Two board-certified radiologists evaluated the grammar and readability, image findings, impression, differential diagnosis, and overall quality of all reports using a 4-point scale. Results: Top-1 and Top-5 accuracies for the different diagnoses were highest for radiologists, followed by GPT-4, GPT-3.5, and GPT-2, in that order (Top-1: 1.00, 0.54, 0.54, and 0.21, respectively; Top-5: 1.00, 0.96, 0.89, and 0.54, respectively). There were no significant differences in qualitative scores about grammar and readability, image findings, and overall quality between radiologists and GPT-3.5 or GPT-4 (p > 0.05). However, qualitative scores of the GPT series in impression and differential diagnosis scores were significantly lower than those of radiologists (p < 0.05). Conclusions: Our preliminary study suggests that GPT-3.5 and GPT-4 have the possibility to generate radiology reports with high readability and reasonable image findings from very short keywords; however, concerns persist regarding the accuracy of impressions and differential diagnoses, thereby requiring verification by radiologists.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Language Models are Few-Shot Learners
Brown, T. B., Mann, B., Ryder, N., Subbiah, M., Kaplan, J., Dhariwal, P., Neelakantan, A., Shyam, P., Sastry, G., Askell, A., et al. (2020) · arXiv · doi:10.48550/arxiv.2005.14165 · Cited by 23,372
Survey of Hallucination in Natural Language Generation
Ji, Z., Lee, N., Frieske, R., Yu, T., Su, D., Xu, Y., Ishii, E., Bang, Y. J., Madotto, A., & Fung, P. (2023) · ACM Computing Surveys · doi:10.1145/3571730 · Cited by 5,025
Survey of Hallucination in Natural Language Generation
Ji, Z., Lee, N., Frieske, R., Yu, T., Su, D., Xu, Y., Ishii, E., Bang, Y., Chen, D., Dai, W., et al. (2022) · arXiv · doi:10.48550/arxiv.2202.03629 · Cited by 4,981
Training language models to follow instructions with human feedback
Ouyang, L., Wu, J., Jiang, X., Almeida, D., Wainwright, C. L., Mishkin, P., Zhang, C., Agarwal, S., Slama, K., Ray, A., et al. (2022) · arXiv · doi:10.48550/arxiv.2203.02155 · Cited by 4,208
Kung, T. H., Cheatham, M., Medenilla, A., Sillos, C., De Leon, L., Elepaño, C., Madriaga, M., Aggabao, R., Diaz-Candido, G., Maningo, J., et al. (2023) · PLOS Digital Health · doi:10.1371/journal.pdig.0000198 · Cited by 4,115 · cited 1×
“Additionally, recent research has shown that GPT performed at or near the passing threshold for all three exams of the USMLE without any specialized training or reinforcement [11], and the usefulness for the transformation and the summarization of radiology reports [12, 13].”
BackgroundKung, T. H., Cheatham, M., ChatGPT, Medenilla, A., Sillos, C., De Leon, L., Elepaño, C., Madriaga, M., Aggabao, R., Diaz-Candido, G., et al. (2022) · doi:10.1101/2022.12.19.22283643 · Cited by 4,115
Adams, L. C., Truhn, D., Busch, F., Kader, A., Niehues, S. M., Makowski, M. R., & Bressem, K. K. (2023) · Radiology · doi:10.1148/radiol.230725 · Cited by 339 · cited 1×
“Additionally, recent research has shown that GPT performed at or near the passing threshold for all three exams of the USMLE without any specialized training or reinforcement [11], and the usefulness for the transformation and the summarization of radiology reports [12, 13].”
BackgroundA Token-level Reference-free Hallucination Detection Benchmark for Free-form Text Generation
Liu, T., Zhang, Y., Brockett, C., Mao, Y., Sui, Z., Chen, W., & Dolan, B. (2022) · Proceedings of the 60th Annual Meeting of the Association for Computational Linguistics (Volume 1: Long Papers) · doi:10.18653/v1/2022.acl-long.464 · Cited by 63
RadAdapt: Radiology Report Summarization via Lightweight Domain Adaptation of Large Language Models
Van Veen, D., Van Uden, C., Attias, M., Pareek, A., Bluethgen, C., Polacin, M., Chiu, W., Delbrouck, J.-B., Zambrano Chaves, J., Langlotz, C., et al. (2023) · The 22nd Workshop on Biomedical Natural Language Processing and BioNLP Shared Tasks · doi:10.18653/v1/2023.bionlp-1.42 · Cited by 25
Cited by
Takita, H., Kabata, D., Walston, S. L., Tatekawa, H., Saito, K., Tsujimoto, Y., Miki, Y., & Ueda, D. (2025) · npj Digital Medicine · doi:10.1038/s41746-025-01543-z · Cited by 203
ChatGPT in radiology: A systematic review of performance, pitfalls, and future perspectives
Keshavarz, P., Bagherieh, S., Nabipoorashrafi, S. A., Chalian, H., Rahsepar, A. A., Kim, G. H. J., Hassani, C., Raman, S. S., & Bedayat, A. (2024) · Diagnostic and Interventional Imaging · doi:10.1016/j.diii.2024.04.003 · Cited by 132
Shan, G., Chen, X., Wang, C., Liu, L., Gu, Y., Jiang, H., & Shi, T. (2025) · JMIR Medical Informatics · doi:10.2196/64963 · Cited by 71
Hamamoto, R., Koyama, T., Takahashi, S., Yasuda, T., Kobayashi, K., Akagi, Y., Kouno, N., Sudo, K., Hirata, M., Sunami, K., et al. (2026) · Journal of Hematology & Oncology · doi:10.1186/s13045-026-01781-y · Cited by 8
Artsi, Y., Klang, E., Collins, J. D., Glicksberg, B. S., Korfiatis, P., Nadkarni, G. N., & Sorin, V. (2025) · medRxiv · doi:10.1101/2025.03.18.25324193 · Cited by 7
Metadata
- Authors
- Nakaura, T., Yoshida, N., Kobayashi, N., Shiraishi, K., Nagayama, Y., Uetani, H., Kidoh, M., Hokamura, M., Funama, Y., & Hirai, T.
- Venue
- Japanese Journal of Radiology
- Published
- 2023-09-15
- Volume
- 42
- Issue
- 2
- Pages
- 190-200
- ISSN
- 1867-1071 (ISSN-L)
- 1867-108X
- OpenAlex
- W4386757338
- Cited by
- 96
- References
- 9
- FWCI
- 3.32
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Preliminary assessment of automated radiology report generation with generative pre-trained transformers: comparing results to radiologist-generated reports. https://app.cochat.ai/papers/10.1007/s11604-023-01487-y
- The paper
- Nakaura, T., Yoshida, N., Kobayashi, N., Shiraishi, K., Nagayama, Y., Uetani, H., Kidoh, M., Hokamura, M., Funama, Y., & Hirai, T. (2024). Preliminary assessment of automated radiology report generation with generative pre-trained transformers: comparing results to radiologist-generated reports. Japanese Journal of Radiology. https://doi.org/10.1007/s11604-023-01487-y
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.