CoChat

Preliminary assessment of automated radiology report generation with generative pre-trained transformers: comparing results to radiologist-generated reports

Open access
Nakaura, Takeshi, Yoshida, Naofumi, Kobayashi, Naoki, Shiraishi, Kaori, Nagayama, Yasunori, Uetani, Hiroyuki, Kidoh, Masafumi, Hokamura, Masamichi, Funama, Yoshinori, Hirai, Toshinori · 2024 · Japanese Journal of Radiology
Cited by 96

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

Purpose: In this preliminary study, we aimed to evaluate the potential of the generative pre-trained transformer (GPT) series for generating radiology reports from concise imaging findings and compare its performance with radiologist-generated reports. Methods: This retrospective study involved 28 patients who underwent computed tomography (CT) scans and had a diagnosed disease with typical imaging findings. Radiology reports were generated using GPT-2, GPT-3.5, and GPT-4 based on the patient’s age, gender, disease site, and imaging findings. We calculated the top-1, top-5 accuracy, and mean average precision (MAP) of differential diagnoses for GPT-2, GPT-3.5, GPT-4, and radiologists. Two board-certified radiologists evaluated the grammar and readability, image findings, impression, differential diagnosis, and overall quality of all reports using a 4-point scale. Results: Top-1 and Top-5 accuracies for the different diagnoses were highest for radiologists, followed by GPT-4, GPT-3.5, and GPT-2, in that order (Top-1: 1.00, 0.54, 0.54, and 0.21, respectively; Top-5: 1.00, 0.96, 0.89, and 0.54, respectively). There were no significant differences in qualitative scores about grammar and readability, image findings, and overall quality between radiologists and GPT-3.5 or GPT-4 (p > 0.05). However, qualitative scores of the GPT series in impression and differential diagnosis scores were significantly lower than those of radiologists (p < 0.05). Conclusions: Our preliminary study suggests that GPT-3.5 and GPT-4 have the possibility to generate radiology reports with high readability and reasonable image findings from very short keywords; however, concerns persist regarding the accuracy of impressions and differential diagnoses, thereby requiring verification by radiologists.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s11604-023-01487-y

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 96

Metadata

Authors
Nakaura, T., Yoshida, N., Kobayashi, N., Shiraishi, K., Nagayama, Y., Uetani, H., Kidoh, M., Hokamura, M., Funama, Y., & Hirai, T.
Venue
Japanese Journal of Radiology
Published
2023-09-15
Volume
42
Issue
2
Pages
190-200
ISSN
  • 1867-1071 (ISSN-L)
  • 1867-108X
OpenAlex
W4386757338
Cited by
96
References
9
FWCI
3.32
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Preliminary assessment of automated radiology report generation with generative pre-trained transformers: comparing results to radiologist-generated reports. https://app.cochat.ai/papers/10.1007/s11604-023-01487-y
The paper
Nakaura, T., Yoshida, N., Kobayashi, N., Shiraishi, K., Nagayama, Y., Uetani, H., Kidoh, M., Hokamura, M., Funama, Y., & Hirai, T. (2024). Preliminary assessment of automated radiology report generation with generative pre-trained transformers: comparing results to radiologist-generated reports. Japanese Journal of Radiology. https://doi.org/10.1007/s11604-023-01487-y

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.