Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 427

The DOI matches its Crossref record.

Glassy Carbon as an Absolute Intensity Calibration Standard for Small-Angle Scattering

Open access
Zhang, Fan, Ilavsky, Jan, Long, Gabrielle G., Quintana, John P. G., Allen, Andrew J., Jemian, Pete R.·2010·Metallurgical and Materials Transactions A

Abstract

Absolute calibration of small-angle scattering (SAS) intensity data (measured in terms of the differential scattering cross section per unit sample volume per unit solid angle) is essential for many important aspects of quantitative SAS analysis, such as obtaining the number density, volume fraction, and specific surface area of the scatterers. It also enables scattering data from different instruments (light, X-ray, or neutron scattering) to be combined, and it can even be useful to detect the existence of artifacts in the experimental data. Different primary or secondary calibration methods are available. In the latter case, absolute intensity calibration requires a stable artifact with the necessary scattering profile. Glassy carbon has sometimes been selected as this intensity calibration standard. Here we review the spatial homogeneity and temporal stability of one type of commercially available glassy carbon that is being used as an intensity calibration standard at a number of SAS facilities. We demonstrate that glassy carbon is sufficiently homogeneous and stable during routine use to be relied upon as a suitable standard for absolute intensity calibration of SAS data.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s11661-009-9950-x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 427

Metadata

Authors
Zhang, F., Ilavsky, J., Long, G. G., Quintana, J. P. G., Allen, A. J., & Jemian, P. R.
Venue
Metallurgical and Materials Transactions A
Published
2009-08-19
Volume
41
Issue
5
Pages
1151-1158
ISSN
  • 1073-5623 (ISSN-L)
  • 1543-1940
OpenAlex
W2103058354
Cited by
427
References
0
FWCI
6.71
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Glassy Carbon as an Absolute Intensity Calibration Standard for Small-Angle Scattering. https://app.cochat.ai/papers/10.1007/s11661-009-9950-x
The paper
Zhang, F., Ilavsky, J., Long, G. G., Quintana, J. P. G., Allen, A. J., & Jemian, P. R. (2010). Glassy Carbon as an Absolute Intensity Calibration Standard for Small-Angle Scattering. Metallurgical and Materials Transactions A. https://doi.org/10.1007/s11661-009-9950-x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.