Validity of Bioelectrical Impedance Analysis to Estimate Body Composition Changes After Bariatric Surgery in Premenopausal Morbidly Women
Abstract
In obese patients, subtle variations of the hydration of soft tissues can propagate errors in bioelectrical impedance analysis (BIA) measures of body composition. Bioelectrical impedance vector analysis (BIVA) is a useful method to evaluate tissue hydration. Laparoscopic adjustable gastric banding (LAGB) is a purely restrictive bariatric surgical procedure resulting in lower fat-free mass (FFM) loss than other malabsorptive or mixed intervention. The aim of this study was to evaluate the 6- and 12-month changes in body composition in a homogeneous group of premenopausal morbidly obese women treated by LAGB by comparing the results of conventional BIA and BIVA with dual-energy X-ray absorptiometry (DXA) method. Forty-five consecutive morbidly obese patients (mean age, 35.3 +/- 9.1 years; body mass index, 34.5-48.7 kg/m(2)) were prospectively evaluated at the Endocrinology Unit of the Department of Molecular and Clinical Endocrinology and Oncology. The LAGB device (Lap-Band System; Inamed Health, Santa Barbara, CA, USA) was inserted laparoscopically. Soft tissue hydration was evaluated by BIVA; fat mass (FM) and FFM were evaluated by BIA (BIA 101 RJL, Akern Bioresearch, Firenze, Italy) and by DXA (Hologic QDR 4500A S/N 45622; Hologic Inc., Bedford, MA, USA). Pre- and postoperative BIVA vectors indicated a normal hydration in all patients. Postoperatively, the excess of body weight loss was mainly due to a decrease in FM. The regression analysis of BIA and DXA methods at baseline and at the 6- and 12-month follow-up for FM r (2) values were 0.98, 0.94, and 0.99, respectively (p < 0.001); FM% r (2) values were 0.91, 0.89, and 0.98, respectively (p < 0.001); and FFM r (2) values were 0.87, 0.82, 0.99, respectively (p < 0.001). BIA and DXA measurements of body composition exhibit a high relative agreement in the study group of normo-hydrated obese subjects. BIA tends to overestimate FFM, but this effect is reduced along with the weight loss during the follow-up. Under the stable hydration, the BIA method may be useful as an alternative to DXA in a selected clinical setting when repeated comparisons of body composition are required.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Bioelectrical impedance analysis is a non-invasive method for evaluation of body composition with high agreement with Dual-energy X-ray absorptiometry.
“In clinical practice, body composition is commonly measured by bioelectrical impedance analysis (BIA), which is a non-invasive method for evaluation of body composition with a high agreement with Dual-energy X-ray absorptiometry [21].”
From Adherence to the Mediterranean Diet, Dietary Patterns and Body Composition in Women with Polycystic Ovary Syndrome (PCOS) (2019) · cites this paper as [21]
BIA is a common and validated method for evaluation of body composition in clinical practice, with high agreement with Dual X-ray Absorptiometry, also among patients with severe obesity.
“BIA is a common and validated method for the evaluation of body composition in the clinical practice, with a high agreement with Dual X-ray Absorptiometry, also among patients with severe obesity [21].”
From Adherence to the Mediterranean Diet, Dietary Patterns and Body Composition in Women with Polycystic Ovary Syndrome (PCOS) (2019) · cites this paper as [21]
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965 · see citing works
Changes in fat-free mass during significant weight loss: a systematic review
Chaston, T. B., Dixon, J. B., & O'Brien, P. E. (2007) · International Journal of Obesity · doi:10.1038/sj.ijo.0803483 · Cited by 493 · see citing works
Validity and accuracy of regional bioelectrical impedance devices to determine whole-body fatness
Lukaski, H. C., & Siders, W. A. (2003) · Nutrition · doi:10.1016/s0899-9007(03)00166-7 · Cited by 73 · cited 1× · see citing works
“Bioelectrical impedance analysis (BIA) represents a simple, inexpensive, and non-invasive means of assessing body composition with broad application in clinics and in weight reduction programs [2, 3].”
Background
Flagged first, then by citations
Cited by
Sorted by citations
Barrea, L., Arnone, A., Annunziata, G., Muscogiuri, G., Laudisio, D., Salzano, C., Pugliese, G., Colao, A., & Savastano, S. (2019) · Nutrients · doi:10.3390/nu11102278 · Cited by 306 · see citing works
“BIA is a common and validated method for the evaluation of body composition in the clinical practice, with a high agreement with Dual X-ray Absorptiometry, also among patients with severe obesity [21].”
MethodSelf-citationNuijten, M. A. H., Eijsvogels, T. M. H., Monpellier, V. M., Janssen, I. M. C., Hazebroek, E. J., & Hopman, M. T. E. (2022) · Obesity Reviews · doi:10.1111/obr.13370 · Cited by 236 · see citing works
Schollenberger, A. E., Karschin, J., Meile, T., Küper, M. A., Königsrainer, A., & Bischoff, S. C. (2016) · Nutrition · doi:10.1016/j.nut.2015.08.005 · Cited by 118 · see citing works
Biolo, G., Di Girolamo, F. G., Breglia, A., Chiuc, M., Baglio, V., Vinci, P., Toigo, G., Lucchin, L., Jurdana, M., Pražnikar, Z. J., et al. (2015) · Clinical Nutrition · doi:10.1016/j.clnu.2014.03.015 · Cited by 113 · see citing works
Rate and determinants of excessive fat-free mass loss after bariatric surgery
Nuijten, M. A. H., Monpellier, V. M., Eijsvogels, T. M. H., Janssen, I. M. C., Hazebroek, E. J., & Hopman, M. T. E. (2020) · Obesity Surgery · doi:10.1007/s11695-020-04654-6 · Cited by 87 · see citing works
Measuring Muscle Mass and Strength in Obesity: a Review of Various Methods
Sizoo, D., de Heide, L. J. M., Emous, M., van Zutphen, T., Navis, G., & van Beek, A. P. (2021) · Obesity Surgery · doi:10.1007/s11695-020-05082-2 · Cited by 77 · see citing works
Hansen, D., Decroix, L., Devos, Y., Nocca, D., Cornelissen, V., Dillemans, B., & Lannoo, M. (2020) · Obesity Surgery · doi:10.1007/s11695-020-04390-x · Cited by 46 · see citing works
Haghighat, N., Ashtary-Larky, D., Bagheri, R., Aghakhani, L., Asbaghi, O., Amini, M., Moeinvaziri, N., Hosseini, B., Wong, A., Shamekhi, Z., et al. (2022) · Surgery for Obesity and Related Diseases · doi:10.1016/j.soard.2022.02.022 · Cited by 36 · see citing works
- Authors
- Savastano, S., Belfiore, A., Di Somma, C., Mauriello, C., Rossi, A., Pizza, G., De Rosa, A., Prestieri, G., Angrisani, L., & Colao, A.
- Affiliations
- Federico II University Hospital (IT)
- University of Naples Federico II (IT)
- Corresponding author
- Savastano, Silvia
- Venue
- Obesity Surgery
- Published
- 2009-10-28
- Volume
- 20
- Issue
- 3
- Pages
- 332-339
- ISSN
- 0960-8923 (ISSN-L)
- 1708-0428
- OpenAlex
- W2170120842
- Cited by
- 100
- References
- 3
- Citations by year
- 2026: 6 · 2025: 3 · 2024: 6 · 2023: 5 · 2022: 4 · 2021: 6 · 2020: 9 · 2019: 3 · 2018: 7 · 2017: 6 · 2016: 5 · 2015: 9 · 2014: 7 · 2013: 6 · 2012: 11
- FWCI
- 3.99
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Obesity Surgery (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Honeywell Federal Manufacturing and Technologies
- Topics
- Health Sciences › Medicine › Physiology › Body Composition Measurement Techniques
- Health Sciences › Medicine › Surgery › Bariatric Surgery and Outcomes
- Health Sciences › Medicine › Surgery › Body Contouring and Surgery
- Keywords
- bioelectrical impedance analysis, bioelectrical impedance vector analysis
- MeSH terms
- Adipose Tissue, Adult, Body Composition, Body Water, Diet, Reducing, Female, Follow-Up Studies, Humans, Obesity, Morbid, Postoperative Period, Prospective Studies, Water-Electrolyte Balance, Gastroplasty, Weight Loss, Absorptiometry, Photon, Body Mass Index, Electric Impedance, Premenopause, Muscle, Skeletal
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review