Validity and accuracy of regional bioelectrical impedance devices to determine whole-body fatness

Lukaski, Henry C., Siders, William A.·2003·Nutrition

Abstract

Objective Growing emphasis on obesity as a risk factor for chronic diseases and commercial availability of impedance devices for the at-home assessment of body fatness have stimulated the need for a critical evaluation of the validity of these instruments. This study determined the reproducibility and accuracy of two commercial impedance devices that use upper (hand-to-hand) or lower (foot-to-foot) body contact electrode placements in adults with a wide range of body fatness. Methods Body composition was assessed with dual x-ray absorptiometry in apparently healthy adults (62 women and 48 men) ages 21 to 60 y, with a range in body mass index of 18.6 to 40.5 kg/m2. Variability in body fatness predicted with the regional body impedance devices was determined in 10 adults on 5 consecutive d. A 50-kHz, tetrapolar bioelectrical impedance plethysmograph with surface electrode placements on the upper and lower limbs was used to determine reference regional and whole-body impedance values. Results Variability in body mass (1%) over 5 d was less than body fatness predicted with the upper (2-10%) and lower (3-5%) body devices. Regional and whole-body impedance values were different (P < 0.05) in the women, whereas upper and lower body values were lower (P < 0.05) than whole-body impedance in the men. Dual x-ray absorptiometric determinations of body fatness were similar to predictions based on models derived from physical characteristics (age, stature, body mass, and sex) but significantly different (P < 0.05) from estimates from the impedance devices, which underestimated body fatness. Bias in predictions of body fatness with the regional devices was systematically (P < 0.0001) related to body fatness. Conclusion Use of regional impedance devices to assess body fatness is limited by a lack of precision and accuracy.

Integrity signals

Registry

Crossref · 10.1016/s0899-9007(03)00166-7

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Single-frequency devices and segmental measures demonstrate the largest differences when compared to DXA, with the inaccuracy increasing in conjunction with higher levels of BMI.

    “However, single-frequency devices and segmental measures demonstrate the largest differences when compared to DXA, with the inaccuracy increasing in conjunction with higher levels of BMI [55,56,57,58].”

Cites

Flagged first, then by citations

1 of the 26 references couldn’t be matched to a known paper.

Cited by

Sorted by citations

Authors
Lukaski, H. C., & Siders, W. A.
Affiliations
Agricultural Research Service (US)
Corresponding author
Lukaski, Henry C.
Venue
Nutrition
Publisher
Elsevier BV
Published
2003-10
Volume
19
Issue
10
Pages
851-857
ISSN
0899-9007 (ISSN-L)
OpenAlex
W1998236052
Cited by
73
References
26
Citations by year
2026: 1 · 2025: 2 · 2024: 2 · 2023: 4 · 2022: 4 · 2021: 3 · 2019: 2 · 2018: 2 · 2017: 5 · 2016: 3 · 2015: 7 · 2014: 3 · 2013: 2 · 2012: 5
FWCI
1.54
Type
journal article
Language
en
Open access
closed
Locations
  • Nutrition (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Physiology › Body Composition Measurement Techniques
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrical and Bioimpedance Tomography
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Obesity, Physical Activity, Diet
Keywords
bioimpedance, adiposity, device validity, measurement accuracy, reproducibility, body composition, obesity, dual-energy X-ray absorptiometry
MeSH terms
Adipose Tissue, Adult, Body Composition, Electric Conductivity, Electrodes, Female, Humans, Male, Middle Aged, Obesity, Sensitivity and Specificity, Reproducibility of Results, Absorptiometry, Photon, Electric Impedance

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review