Validation Study of Multi-Frequency Bioelectrical Impedance with Dual-Energy X-ray Absorptiometry Among Obese Patients
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Disease Burden Associated With Overweight and Obesity
Must, A. (1999) · JAMA · doi:10.1001/jama.282.16.1523 · Cited by 4,780 · cited 1×
“The accumulation of the latter is associated with an increased risk of several diseases, such as type 2 diabetes and cardiovascular diseases [3].”
BackgroundBioelectrical impedance analysis—part II: utilization in clinical practice
Kyle, U. G., Bosaeus, I., De Lorenzo, A. D., Deurenberg, P., Elia, M., Manuel Gómez, J., Lilienthal Heitmann, B., Kent-Smith, L., Melchior, J.-C., Pirlich, M., et al. (2004) · Clinical Nutrition · doi:10.1016/j.clnu.2004.09.012 · Cited by 2,350 · cited 2×
“Studies have showed that BIA is a valid instrument for patients with a BMI up to 34 kg/m(2) [7].”
BackgroundEpidemiology: Beyond the Basics
Szklo, M., & Nieto, F. J. (1999) · Cited by 1,441
Applied body composition assessment
(1996) · Choice Reviews Online · doi:10.5860/choice.34-0910 · Cited by 671 · cited 1×
“However, unlike the single-frequency bioelectrical impedance, it includes impedances at multiple frequencies (0, 1, 5, 50, 100, 200 to 500 kHz) in order to evaluate FFM, the total body water, intracellular water and extracellular water, which can further improve the accuracy of the results [13].”
BackgroundApplied body composition assessment
Pintauro, S. J. (2005) · American Journal of Human Biology · doi:10.1002/ajhb.20101 · Cited by 285
Dual-energy X-ray absorptiometry: fat estimation errors due to variation in soft tissue hydration
Pietrobelli, A., Wang, Z., Formica, C., & Heymsfield, S. B. (1998) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1998.274.5.e808 · Cited by 225
Segmental body composition assessed by bioelectrical impedance analysis and DEXA in humans
Bracco, D., Thiébaud, D., Chioléro, R. L., Landry, M., Burckhardt, P., & Schutz, Y. (1996) · Journal of Applied Physiology · doi:10.1152/jappl.1996.81.6.2580 · Cited by 159 · cited 1×
“There is also a change in intra- and extracellular water in these patients, which may also interfere with the results [8].”
ResultLOHMAN, T. G., HARRIS, M., TEIXEIRA, P. J., & WEISS, L. (2000) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.2000.tb06420.x · Cited by 153 · cited 1×
“[15], after extensive review of the literature, theorized that a 5 % change in water present in FFM could affect the measurement of the % of body fat (%BF) in only 2 % of cases considered [15].”
BackgroundBioelectrical Impedance Analysis
Chumlea, W. C., & Sun, S. S. (2005) · Human Body Composition · doi:10.5040/9781492596950.ch-006 · Cited by 130
Body composition measurement in severe obesity
Das, S. K. (2005) · Current Opinion in Clinical Nutrition & Metabolic Care · doi:10.1097/01.mco.0000171122.60665.5f · Cited by 86 · cited 4×
“One major obstacle is the increase in total body water, especially extracellular water in relation to intracellular water [5], which impedes an accurate BC measurement when using various methods.”
BackgroundInfluentialStrain, G. W., Wang, J., Gagner, M., Pomp, A., Inabnet, W. B., & Heymsfield, S. B. (2008) · Obesity · doi:10.1038/oby.2008.321 · Cited by 76
The association between BMI value and long-term mortality
Wändell, P. E., Carlsson, A. C., & Theobald, H. (2009) · International Journal of Obesity · doi:10.1038/ijo.2009.36 · Cited by 65 · cited 1×
“increases the risk of death, whatever the actual cause may be [1].”
BackgroundWeight Loss Outcome After Silastic Ring Roux-en-Y Gastric Bypass: 8 Years of Follow-up
Valezi, A. C., Mali, J., Menezes, M. A., de Brito, E. M., & de Souza, S. A. F. (2010) · Obesity Surgery · doi:10.1007/s11695-010-0264-2 · Cited by 63 · cited 1×
“and, principally, the long-termmaintenance of this weight loss [6].”
BackgroundHow to Estimate Fat Mass in Overweight and Obese Subjects
Donini, L. M., Poggiogalle, E., del Balzo, V., Lubrano, C., Faliva, M. A., Opizzi, A., Perna, S., Pinto, A., & Rondanelli, M. (2013) · International Journal of Endocrinology · doi:10.1155/2013/285680 · Cited by 62 · cited 15×
“Currently, BMI (weight/(height) 2) is the most common parameter used to classify the nutritional status of individuals.”
BackgroundMethodInfluentialHendel, H. W., Gotfredsen, A., Højgaard, L., Andersen, T., & Hilsted, J. (1996) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365519609088814 · Cited by 43 · cited 1×
“However, studies show that in cases of clinically severe obesity, most prediction equations used with Bioelectral Impedance Analysis are unable to ascertain the static BC and over time are not reproducible for individuals [11].”
BackgroundKehayias, J. J., Heymsfield, S. B., Dilmanian, F. A., Wang, J., Günther, D., & Pierson, R. N. (1990) · Springer eBooks · doi:10.1007/978-1-4613-1473-8_46 · Cited by 10 · cited 1×
“Besides this, obese patients often exceed the capacity of the DXA unit [10].”
Background
Cited by
Schollenberger, A. E., Karschin, J., Meile, T., Küper, M. A., Königsrainer, A., & Bischoff, S. C. (2016) · Nutrition · doi:10.1016/j.nut.2015.08.005 · Cited by 118
Twelve key nutritional issues in bariatric surgery
Thibault, R., Huber, O., Azagury, D. E., & Pichard, C. (2016) · Clinical Nutrition · doi:10.1016/j.clnu.2015.02.012 · Cited by 116
Antonio, J., Kenyon, M., Ellerbroek, A., Carson, C., Burgess, V., Tyler-Palmer, D., Mike, J., Roberts, J., Angeli, G., & Peacock, C. (2019) · Journal of Functional Morphology and Kinesiology · doi:10.3390/jfmk4020023 · Cited by 106
Gamifying Accelerometer Use Increases Physical Activity Levels of Sedentary Office Workers
Gremaud, A. L., Carr, L. J., Simmering, J. E., Evans, N. J., Cremer, J. F., Segre, A. M., Polgreen, L. A., & Polgreen, P. M. (2018) · Journal of the American Heart Association · doi:10.1161/jaha.117.007735 · Cited by 89
Rate and determinants of excessive fat-free mass loss after bariatric surgery
Nuijten, M. A. H., Monpellier, V. M., Eijsvogels, T. M. H., Janssen, I. M. C., Hazebroek, E. J., & Hopman, M. T. E. (2020) · Obesity Surgery · doi:10.1007/s11695-020-04654-6 · Cited by 87
“BIA provides a simple, inexpensive and non-invasive alternative for dual-energy X-ray absorptiometry (DXA) measurements, and studies show high correlations between BIA and DXA [25, 26].”
Background
Metadata
- Authors
- Faria, S. L., Faria, O. P., Cardeal, M. D. A., & Ito, M. K.
- Venue
- Obesity Surgery
- Published
- 2014-01-26
- Volume
- 24
- Issue
- 9
- Pages
- 1476-1480
- ISSN
- 0960-8923 (ISSN-L)
- 1708-0428
- OpenAlex
- W2032215371
- Cited by
- 170
- References
- 16
- FWCI
- 8.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.