Power sources and electrical recharging strategies for implantable medical devices
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Piezoelectric Nanogenerators Based on Zinc Oxide Nanowire Arrays
Wang, Z. L., & Song, J. (2006) · Science · doi:10.1126/science.1124005 · Cited by 7,922
A high-performance brain–computer interface
Santhanam, G., Ryu, S. I., Yu, B. M., Afshar, A., & Shenoy, K. V. (2006) · Nature · doi:10.1038/nature04968 · Cited by 698
Cited by
Power Approaches for Implantable Medical Devices
Amar, A., Kouki, A., & Cao, H. (2015) · Sensors · doi:10.3390/s151128889 · Cited by 432
Advances in the design and assembly of flexible thermoelectric device
Cao, T., Shi, X.-L., & Chen, Z.-G. (2023) · Progress in Materials Science · doi:10.1016/j.pmatsci.2022.101003 · Cited by 387
Biologically derived melanin electrodes in aqueous sodium-ion energy storage devices
Kim, Y. J., Wu, W., Chun, S.-E., Whitacre, J. F., & Bettinger, C. J. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1314345110 · Cited by 335
The 2021 battery technology roadmap
Ma, J., Li, Y., Grundish, N. S., Goodenough, J. B., Chen, Y., Guo, L., Peng, Z., Qi, X., Yang, F., Qie, L., et al. (2021) · Journal of Physics D: Applied Physics · doi:10.1088/1361-6463/abd353 · Cited by 269
Challenges for successful implantation of biofuel cells
Zebda, A., Alcaraz, J.-P., Vadgama, P., Shleev, S., Minteer, S. D., Boucher, F., Cinquin, P., & Martin, D. K. (2018) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2018.05.011 · Cited by 224
Self‐Powered Implantable Medical Devices: Photovoltaic Energy Harvesting Review
Zhao, J., Ghannam, R., Htet, K. O., Liu, Y., Law, M., Roy, V. A. L., Michel, B., Imran, M. A., & Heidari, H. (2020) · Advanced Healthcare Materials · doi:10.1002/adhm.202000779 · Cited by 218
A review of acoustic power transfer for bio-medical implants
Basaeri, H., Christensen, D. B., & Roundy, S. (2016) · Smart Materials and Structures · doi:10.1088/0964-1726/25/12/123001 · Cited by 202
Cadei, A., Dionisi, A., Sardini, E., & Serpelloni, M. (2014) · Measurement Science and Technology · doi:10.1088/0957-0233/25/1/012003 · Cited by 158
Ultrasound-induced wireless energy harvesting: from materials strategies to functional applications
Jiang, L., Yang, Y., Chen, Y., & Zhou, Q. (2020) · Nano Energy · doi:10.1016/j.nanoen.2020.105131 · Cited by 131
Review on medical implantable antenna technology and imminent research challenges
Soliman, M. M., Chowdhury, M. E. H., Khandakar, A., Islam, M. T., Qiblawey, Y., Musharavati, F., & Zal Nezhad, E. (2021) · Sensors · doi:10.3390/s21093163 · Cited by 95
Metadata
- Authors
- Wei, X., & Liu, J.
- Venue
- Frontiers of Energy and Power Engineering in China
- Published
- 2008-03
- Volume
- 2
- Issue
- 1
- Pages
- 1-13
- ISSN
- 1673-7393 (ISSN-L)
- 1673-7504
- OpenAlex
- W1025570106
- Cited by
- 188
- References
- 2
- FWCI
- 2.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.