CoChat

On the measurement of critical micelle concentrations of pure and technical‐grade nonionic surfactants

Patist, A., Bhagwat, S. S., Penfield, K. W., Aikens, P., Shah, D. O. · 2000 · Journal of Surfactants and Detergents
Cited by 334

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

The critical micelle concentrations (CMC) of nine commercial nonionic surfactants (Tween 20, 22, 40, 60, and 80; Triton X‐100; Brij 35, 58, and 78) and two pure nonionics [C 12(EO)5 and C 12(EO)8] were determined by surface tension and dye micellization methods. Commercially available nonionic surfactants (technical grade) usually contain impurities and have a broad molecular weight distribution owing to the degree of ethoxylation. It was shown that the surface tension method (Wilhelmy plate) is very sensitive to the presence of impurities. Much lower CMC values were obtained with the surface tension method than with the dye micellization method (up to 6.5 times for Tween 22). In the presence of highly surfaceactive impurities, the air/liquid interface is already saturated at concentrations well below the true CMC, leading to a wrong interpretation of the break in the curve of surface tension (γ) vs. concentration of nonionic surfactant (log C). The actual onset of micellization happens at higher concentrations, as measured by the dye micellization method. Furthermore, it was shown that when a commercial surfactant sample (Tween 20) is subjected to foam fractionation, thereby removing species with higher surface activity, the sample yields almost the same CMC values as measured by surface tension and dye micellization methods. It was found that for monodisperse pure nonionic surfactants, both CMC determination methods yield the same results. Therefore, this study indicates that precaution should be taken when determining the CMC of commercial nonionic surfactants by the surface tension method, as it indicates the surface concentration of all surface‐active species at the surface only, whereas the dye method indicates the presence of micelles in the bulk solution.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s11743-000-0113-4

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

Metadata

Authors
Patist, A., Bhagwat, S. S., Penfield, K. W., Aikens, P., & Shah, D. O.
Venue
Journal of Surfactants and Detergents
Publisher
Wiley
Published
2000-01
Volume
3
Issue
1
Pages
53-58
ISSN
  • 1097-3958 (ISSN-L)
  • 1558-9293
OpenAlex
W2017434735
Cited by
334
References
7
FWCI
2.03
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.