A robust method for critical micelle concentration determination using coumarin-6 as a fluorescent probe
The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
Critical micelle concentration (CMC) is the point at which micelles are self-assembled from surfactants added to the system. We established a simple method based on dye micellization, using coumarin-6 as a fluorescent probe for CMC determination.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Drug-like properties and the causes of poor solubility and poor permeability
Lipinski, C. A. (2000) · Journal of Pharmacological and Toxicological Methods · doi:10.1016/s1056-8719(00)00107-6 · Cited by 3,734
Kalyanasundaram, K., & Thomas, J. K. (1977) · Journal of the American Chemical Society · doi:10.1021/ja00449a004 · Cited by 3,464
Principles of colloid and surface chemistry
Matijević, E. (1979) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(79)90045-6 · Cited by 2,781
Micellar Nanocarriers: Pharmaceutical Perspectives
Torchilin, V. P. (2006) · Pharmaceutical Research · doi:10.1007/s11095-006-9132-0 · Cited by 1,910
On the determination of the critical micelle concentration by the pyrene 1:3 ratio method
Aguiar, J., Carpena, P., Molina-Bolı́var, J. A., & Carnero Ruiz, C. (2003) · Journal of Colloid and Interface Science · doi:10.1016/s0021-9797(02)00082-6 · Cited by 817
Advances in polymeric micelles for drug delivery and tumor targeting
Kedar, U., Phutane, P., Shidhaye, S., & Kadam, V. (2010) · Nanomedicine: Nanotechnology, Biology and Medicine · doi:10.1016/j.nano.2010.05.005 · Cited by 791
2° Surfactants and their applications
Schramm, L. L., Stasiuk, E. N., & Marangoni, D. G. (2003) · Annu. Rep. Prog. Chem., Sect. C: Phys. Chem. · doi:10.1039/b208499f · Cited by 664
Determination of Critical Micelle Concentration of Some Surfactants by Three Techniques
Dominguez, A., Fernandez, A., Gonzalez, N., Iglesias, E., & Montenegro, L. (1997) · Journal of Chemical Education · doi:10.1021/ed074p1227 · Cited by 660
Nanonization strategies for poorly water-soluble drugs
Chen, H., Khemtong, C., Yang, X., Chang, X., & Gao, J. (2011) · Drug Discovery Today · doi:10.1016/j.drudis.2010.02.009 · Cited by 642
Polymeric micelles and alternative nanonized delivery vehicles for poorly soluble drugs
Lu, Y., & Park, K. (2013) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2012.08.042 · Cited by 572
Research works printed but not linked: 2
- Lu, 2014, Int. J. Pharm., 453, 198, 10.1016/j.ijpharm.2012.08.042.polymeric · doi:10.1016/j.ijpharm.2012.08.042.polymeric
- Malvern Instruments Ltd , Surfactant micelle characterization using dynamic light scattering , Zetasizer Nano Application Note, MRK809-01, 2006 , pp. 1–5
Cited by
Ghezzi, M., Pescina, S., Padula, C., Santi, P., Del Favero, E., Cantù, L., & Nicoli, S. (2021) · Journal of Controlled Release · doi:10.1016/j.jconrel.2021.02.031 · Cited by 1,135
Junnuthula, V., Kolimi, P., Nyavanandi, D., Sampathi, S., Vora, L. K., & Dyawanapelly, S. (2022) · Pharmaceutics · doi:10.3390/pharmaceutics14091860 · Cited by 115
“8 Fluorescence (Pyrene, Coumarin-6, Nile Red, 1,6-diphenyl-1,3,5-hexatriene (DPH)) CMC of PM [51]”
BackgroundNovel amphiphilic chitosan micelles as carriers for hydrophobic anticancer drugs
Almeida, A., Araújo, M., Novoa-Carballal, R., Andrade, F., Gonçalves, H., Reis, R. L., Lúcio, M., Schwartz, S., & Sarmento, B. F. C. C. (2020) · Materials Science and Engineering C · doi:10.1016/j.msec.2020.110920 · Cited by 113
Predicting Critical Micelle Concentrations for Surfactants Using Graph Convolutional Neural Networks
Qin, S., Jin, T., Lehn, R. C. V., & Zavala, V. M. (2021) · The Journal of Physical Chemistry B · doi:10.1021/acs.jpcb.1c05264 · Cited by 72
Zhang, Z., Wang, L., Guo, Z., Sun, Y., & Yan, J. (2024) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2024.113871 · Cited by 60
Metadata
- Authors
- Fluksman, A., & Benny, O.
- Affiliations
- Hebrew University of Jerusalem (IL)
- Corresponding author
- Benny, Ofra
- Venue
- Analytical Methods
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2019
- Volume
- 11
- Issue
- 30
- Pages
- 3810-3818
- ISSN
- 1759-9660 (ISSN-L)
- 1759-9679
- OpenAlex
- W2955586509
- Cited by
- 92
- References
- 34
- Citations by year
- 2026: 5 · 2025: 16 · 2024: 20 · 2023: 12 · 2022: 16 · 2021: 12 · 2020: 11
- FWCI
- 3.82
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Analytical Methods (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Physical and Theoretical Chemistry › Surfactants and Colloidal Systems
- Physical Sciences › Environmental Science › Environmental Chemistry › Environmental Chemistry and Analysis
- Physical Sciences › Chemistry › Organic Chemistry › Advanced Polymer Synthesis and Characterization
- Keywords
- critical micelle concentration, coumarin 6, fluorescent probes, surfactant self-assembly, micelles
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A robust method for critical micelle concentration determination using coumarin-6 as a fluorescent probe. https://app.cochat.ai/papers/10.1039/c9ay00577c
- The paper
- Fluksman, A., & Benny, O. (2019). A robust method for critical micelle concentration determination using coumarin-6 as a fluorescent probe. Analytical Methods. https://doi.org/10.1039/c9ay00577c
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.