Atmospheric pressure chemical ionization mass spectrometry for analysis of lipids
The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
Atmospheric pressure chemical ionization (APCI) mass spectrometry (MS) has proven to be a very valuable technique for analysis of lipids from a variety of classes. This instrumental method readily produces useful ions with gentle fragmentation from large neutral molecules such as triacylglycerols and carotenoids, which are often difficult to analyze using other techniques. Molecules that are easily ionized, such as phospholipids, produce molecular ions and diagnostically useful fragment ions that are complementary to those produced by methods such as electrospray ionization MS with collision‐induced dissociation. The simplicity and versatility of APCI‐MS make it an ideal tool for use in solving hitherto very difficult analytical problems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray interface for liquid chromatographs and mass spectrometers
Whitehouse, C. M., Dreyer, R. N., Yamashita, M., & Fenn, J. B. (1985) · Analytical Chemistry · doi:10.1021/ac00280a023 · Cited by 1,512
Bruins, A. P., Covey, T. R., & Henion, J. D. (1987) · Analytical Chemistry · doi:10.1021/ac00149a003 · Cited by 879
Interpreting mass spectra of multiply charged ions
Mann, M., Meng, C. K., & Fenn, J. B. (1989) · Analytical Chemistry · doi:10.1021/ac00190a023 · Cited by 588
Horning, E. C., Horning, M. G., Carroll, D. I., Dzidic, I., & Stillwell, R. N. (1973) · Analytical Chemistry · doi:10.1021/ac60328a035 · Cited by 552
Hopmans, E. C., Schouten, S., Pancost, R. D., van der Meer, M. T. J., & Sinninghe Damst�, J. S. (2000) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(20000415)14:7<585::aid-rcm913>3.0.co;2-n · Cited by 485
Carroll, D. I., Dzidic, I., Stillwell, R. N., Haegele, K. D., & Horning, E. C. (1975) · Analytical Chemistry · doi:10.1021/ac60364a031 · Cited by 392
Parcerisa, J., Casals, I., Boatella, J., Codony, R., & Rafecas, M. (2000) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)00352-6 · Cited by 172
Antioxidant Reactions of β-Carotene: Identification of Carotenoid−Radical Adducts
Liebler, D. C., & McClure, T. D. (1996) · Chemical Research in Toxicology · doi:10.1021/tx950151t · Cited by 153
Bylund, J., Ericsson, J., & Oliw, E. H. (1998) · Analytical Biochemistry · doi:10.1006/abio.1998.2897 · Cited by 151
Determination of steroids by liquid chromatography/mass spectrometry
Ma, Y.-C., & Kim, H.-Y. (1997) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(97)00122-0 · Cited by 146
New techniques and applications in lipid analysis
McDonald, R. E., & Mossoba, M. M. (1997) · Cited by 139
Lacker, T., Strohschein, S., & Albert, K. (1999) · Journal of Chromatography A · doi:10.1016/s0021-9673(99)00584-1 · Cited by 131
Analysis of triglycerides using atmospheric pressure chemical ionization mass spectrometry
Byrdwell, W. C., & Emken, E. A. (1995) · Lipids · doi:10.1007/bf02538272 · Cited by 122
Self-citationKarlsson, A., Michélsen, P., & Odham, G. (1998) · Journal of Mass Spectrometry · Cited by 112
van Breemen, R. B., Huang, C.-R., Tan, Y., Sander, L. C., & Schilling, A. B. (1996) · Journal of Mass Spectrometry · Cited by 102
van Breemen, R. B., Nikolic, D. S., Xu, X., Xiong, Y., Lieshout, M. V., West, C. E., & Schilling, A. B. (1998) · Journal of Chromatography A · doi:10.1016/s0021-9673(97)01138-2 · Cited by 100
Neff, W. E., & Byrdwell, W. C. (1998) · Journal of Chromatography A · doi:10.1016/s0021-9673(98)00553-6 · Cited by 95
Self-citationByrdwell, W. C. (1998) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19980314)12:5<256::aid-rcm149>3.0.co;2-8 · Cited by 88
Self-citationFredline, V. F., Taylor, P. J., Dodds, H. M., & Johnson, A. G. (1997) · Analytical Biochemistry · doi:10.1006/abio.1997.2340 · Cited by 61
Wang, Y., Xu, X., Lieshout, M. V., West, C. E., Lugtenburg, J., Verhoeven, M. A., Creemers, A. F. L., Muhilal, & van Breemen, R. B. (2000) · Analytical Chemistry · doi:10.1021/ac000454e · Cited by 55
Rule, G. S., & Henion, J. D. (1999) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(99)00107-5 · Cited by 53
Laakso, P. (1997) · Journal of the American Oil Chemists Society · doi:10.1007/s11746-997-0060-x · Cited by 41
Gamoh, K., Abé, H., Shimada, K., & Takatsuto, S. (1996) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19960610)10:8<903::aid-rcm564>3.0.co;2-2 · Cited by 36
Tuomola, M., Sandell, M. A., & Manninen, P. (1998) · Journal of Chromatography B Biomedical Sciences and Applications · doi:10.1016/s0378-4347(98)00409-5 · Cited by 31
Shimada, K., & Mukai, Y. (1998) · Journal of Chromatography B Biomedical Sciences and Applications · doi:10.1016/s0378-4347(98)00227-8 · Cited by 30
Mu, H., & Høy, C. (2000) · Journal of Chromatography B Biomedical Sciences and Applications · doi:10.1016/s0378-4347(00)00378-9 · Cited by 30
Řezanka, T. (2000) · Biochemical Systematics and Ecology · doi:10.1016/s0305-1978(99)00125-8 · Cited by 30
Tang, G., Andrien, B. A., Dolnikowski, G. G., et al. (1997) · Methods in enzymology on CD-ROM/Methods in enzymology · doi:10.1016/s0076-6879(97)82103-9 · Cited by 27
Nakajima, M., Yamato, S., & Shimada, K. (1998) · Biomedical Chromatography · doi:10.1002/(sici)1099-0801(199807/08)12:4<211::aid-bmc737>3.0.co;2-n · Cited by 22
HAGIWARA, T., YASUNO, T., Funayama, K., & Suzuki, S. (1997) · Food Hygiene and Safety Science (Shokuhin Eiseigaku Zasshi) · doi:10.3358/shokueishi.38.4_211 · Cited by 13
Sjöberg, P. J. R., & Markides, K. E. (1997) · Journal of Chromatography A · doi:10.1016/s0021-9673(97)00665-1 · Cited by 12
Analysis of brassinosteroids by liquid chromatography/mass spectrometry.
Gamoh, K., Prescott, M. C., Goad, L. J., & Takatsuto, S. (1996) · BUNSEKI KAGAKU · doi:10.2116/bunsekikagaku.45.523 · Cited by 12
Ikegawa, S., Goto, T., Mano, N., & Goto, J. (1998) · Steroids · doi:10.1016/s0039-128x(98)00070-1 · Cited by 8
Cited by
Chemistry of Atmospheric Brown Carbon
Laskin, A., Laskin, J., & Nizkorodov, S. A. (2015) · Chemical Reviews · doi:10.1021/cr5006167 · Cited by 1,832
Han, X., & Gross, R. W. (2003) · Journal of Lipid Research · doi:10.1194/jlr.r300004-jlr200 · Cited by 914
“Alternately, other soft ionization techniques of MS, such as atmospheric pressure chemical ionization, which has recently been reviewed (43), may be employed to analyze these nonpolar lipids.”
Watson, A. D. (2006) · Journal of Lipid Research · doi:10.1194/jlr.r600022-jlr200 · Cited by 455
Holčapek, M., Jandera, P., Zderadička, P., & Hrubá, L. (2003) · Journal of Chromatography A · doi:10.1016/s0021-9673(03)01030-6 · Cited by 348
An update of MALDI-TOF mass spectrometry in lipid research
Fuchs, B., Süß, R., & Schiller, J. (2010) · Progress in Lipid Research · doi:10.1016/j.plipres.2010.07.001 · Cited by 324
Metadata
- Authors
- Byrdwell, W. C.
- Venue
- Lipids
- Publisher
- Wiley
- Published
- 2001-04
- Volume
- 36
- Issue
- 4
- Pages
- 327-346
- ISSN
- 0024-4201 (ISSN-L)
- 1558-9307
- OpenAlex
- W2028583333
- Cited by
- 279
- References
- 33
- FWCI
- 3.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.