The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Are Current Measurements of Lower Extremity Muscle Architecture Accurate?
Open accessAbstract
Skeletal muscle architecture is defined as the arrangement of fibers in a muscle and functionally defines performance capacity. Architectural values are used to model muscle-joint behavior and to make surgical decisions. The two most extensively used human lower extremity data sets consist of five total specimens of unknown size, gender, and age. Therefore, it is critically important to generate a high-fidelity human lower extremity muscle architecture data set. We disassembled 27 muscles from 21 human lower extremities to characterize muscle fiber length and physiologic cross-sectional area, which define the excursion and force-generating capacities of a muscle. Based on their architectural features, the soleus, gluteus medius, and vastus lateralis are the strongest muscles, whereas the sartorius, gracilis, and semitendinosus have the largest excursion. The plantarflexors, knee extensors, and hip adductors are the strongest muscle groups acting at each joint, whereas the hip adductors and hip extensors have the largest excursion. Contrary to previous assertions, two-joint muscles do not necessarily have longer fibers than single-joint muscles as seen by the similarity of knee flexor and extensor fiber lengths. These high-resolution data will facilitate the development of more accurate musculoskeletal models and challenge existing theories of muscle design; we believe they will aid in surgical decision making.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The variation in isometric tension with sarcomere length in vertebrate muscle fibres
Gordon, A. M., Huxley, A. F., & Julian, F. J. (1966) · The Journal of Physiology · doi:10.1113/jphysiol.1966.sp007909 · Cited by 3,152
FIBER ARCHITECTURE AND MUSCLE FUNCTION
Gans, C. (1982) · Exercise and Sport Sciences Reviews · doi:10.1249/00003677-198201000-00006 · Cited by 491
Cited by
Mechanics of the Human Hamstring Muscles during Sprinting
SCHACHE, A. G., DORN, T. W., BLANCH, P. D., BROWN, N. A. T., & PANDY, M. G. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e318236a3d2 · Cited by 401
Skeletal muscle design to meet functional demands
Lieber, R. L., & Ward, S. R. (2011) · Philosophical Transactions of the Royal Society B: Biological Sciences · doi:10.1098/rstb.2010.0316 · Cited by 377
Self-citationArnold, E. M., Hamner, S. R., Seth, A., Millard, M., & Delp, S. L. (2013) · Journal of Experimental Biology · doi:10.1242/jeb.075697 · Cited by 261
Spatial variations in Achilles tendon shear wave speed
DeWall, R. J., Slane, L. C., Lee, K. S., & Thelen, D. G. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.05.008 · Cited by 105
Wagenmakers, A. J. M., Strauss, J. A., Shepherd, S. O., Keske, M. A., & Cocks, M. (2016) · The Journal of Physiology · doi:10.1113/jphysiol.2014.284513 · Cited by 78
Metadata
- Authors
- Ward, S. R., Eng, C. M., Smallwood, L. H., & Lieber, R. L.
- Venue
- Clinical Orthopaedics and Related Research
- Published
- 2008-10-30
- Volume
- 467
- Issue
- 4
- Pages
- 1074-1082
- ISSN
- 0009-921X (ISSN-L)
- 1528-1132
- OpenAlex
- W2053518639
- Cited by
- 693
- References
- 2
- FWCI
- 9.38
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Are Current Measurements of Lower Extremity Muscle Architecture Accurate? https://app.cochat.ai/papers/10.1007/s11999-008-0594-8
- The paper
- Ward, S. R., Eng, C. M., Smallwood, L. H., & Lieber, R. L. (2009). Are Current Measurements of Lower Extremity Muscle Architecture Accurate? Clinical Orthopaedics and Related Research. https://doi.org/10.1007/s11999-008-0594-8
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.