CoChat

Midterm Assessment of Causes and Results of Revision Total Knee Arthroplasty

Open access
Hossain, Fahad, Patel, Shelain, Haddad, Fares Sami · 2010 · Clinical Orthopaedics & Related Research
Cited by 215

The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.

Abstract

BACKGROUND: There is limited information regarding revision total knee arthroplasty (TKA) with respect to etiology, outcome, and long-term survival comparing different implant types. QUESTIONS/PURPOSES: We compared patient outcomes, survivorship and modes of failure and the most common etiologic factors for rerevision between different revision implant types. METHODS: We retrospectively reviewed 349 cases of revision TKA in 343 patients whose mean age was 67.8 years. Three implant types were used: posterior stabilized, condylar constrained knee, and rotating hinge. The etiologies included infection (32.7%), aseptic loosening (14.9%), and polyethylene wear (12.3%). The minimum followup was 12 months (mean, 57.7 months; range, 12-120 months). RESULTS: The mean Knee Society scores were 89 (range, 48-94), 88.9 (range, 45-95), and 84 (range, 56-94) and the mean ranges of motion were 110.0 degrees (range, 70 degrees -125 degrees ), 106.1 degrees (range, 70 degrees -120 degrees ), and 111.7 degrees (range, 85 degrees -125 degrees ) for the posterior stabilized, condylar constrained knee, and rotating hinge types, respectively. The rotating hinge group had the highest satisfaction rates (88%). Overall 10-year survivorship was 90.6% with highest survivorship seen in the rotating hinge group. The most common causes for rerevision were infection (2.9% of our cohort), instability (1.7%), and aseptic loosening (1.4%). The mean overall time to rerevision was 69.9 months (range, 11-119 months). CONCLUSIONS: In our experience periprosthetic infection is the most common cause of failure of both primary and revision TKA. Functional outcome and range of motion improve irrespective of revision implant type. The rotating hinge prosthesis provides patient satisfaction and survivorship similar to that of other implant types. LEVEL OF EVIDENCE: Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s11999-009-1204-0

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 16 references

Metadata

Authors
Hossain, F., Patel, S., & Haddad, F. S.
Venue
Clinical Orthopaedics & Related Research
Published
2010-05
Volume
468
Issue
5
Pages
1221-1228
ISSN
0009-921X (ISSN-L)
OpenAlex
W2065153076
Cited by
215
References
16
FWCI
8.69
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Midterm Assessment of Causes and Results of Revision Total Knee Arthroplasty. https://app.cochat.ai/papers/10.1007/s11999-009-1204-0
The paper
Hossain, F., Patel, S., & Haddad, F. S. (2010). Midterm Assessment of Causes and Results of Revision Total Knee Arthroplasty. Clinical Orthopaedics & Related Research. https://doi.org/10.1007/s11999-009-1204-0

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.