Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 242

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Osseointegrated Titanium Implants for Limb Prostheses Attachments: Infectious Complications

Open access
Tillander, Jonatan, Hagberg, Kerstin, Hagberg, Lars, Brånemark, Rickard · 2010 · Clinical Orthopaedics & Related Research

Abstract

BACKGROUND: The concept of osseointegration involves direct contact between titanium implant and bone. This transcutaneous prosthetic system for amputees is intended to assure stable long-term fixation. Most metal transcutaneous implants have failed, primarily owing to infection. QUESTIONS/PURPOSES: We determined the frequency and describe the presentation of infectious complications with this novel method. We also evaluated the bacterial flora at the skin-penetration area and its relation to the development of local and implant-related infection. PATIENTS AND METHODS: We prospectively followed 39 patients with arm and leg amputations fitted with transcutaneous osseointegrated titanium implants a mean of 56 months earlier (range, 132-133 months). There were 33 femoral, one tibial, four ulnar, four radial, and three humeral implants. Patients were selected during a 6-month period in 2005 and identically reevaluated after 3 years. Implant infection was defined as definite, probable, or possible based on clinical, radiologic, and microbiologic evidence. RESULTS: The frequency of implant infection was 5% at inclusion and 18% at followup. One patient with infection recovered owing to antibiotic treatment and another patient had the implant removed. Most implant infections had low infectious activity, and in five of the seven patients with infections, prosthetic use was not affected. The most common bacteria in superficial and deep cultures were Staphylococcus aureus and coagulase-negative staphylococci. CONCLUSIONS: Despite frequent colonization around the skin-implant interface by potentially virulent bacteria such as Staphylococcus aureus and bacteria associated with biomedical device infections such as coagulase-negative staphylococci, this titanium implant system for bone-anchored prostheses caused few infections leading to disability or implant removal. LEVEL OF EVIDENCE: Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s11999-010-1370-0

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Research works printed but not linked: 8

  1. 1990, Adell, R., Eriksson, B., Lekholm, U., Branemark, PI. and Jemt, T. Long-term follow-up study of osseointegrated implants in the treatment of totally edentulous jaws., Int J Oral Maxillofac Implants, 5, 347
  2. 1996, Arens, S., Schlegel, U., Printzen, G., Ziegler, WJ., Perren, SM. and Hansis, M. Influence of materials for fixation implants on local infection: an experimental study of steel versus titanium DCP in rabbits., J Bone Joint Surg Br, 78, 647
  3. 1998, Atkins, BL., Athanasou, N., Deeks, JJ., Crook, DW., Simpson, H., Peto, TE., McLardy-Smith, P. and Berendt, AR. Prospective evaluation of criteria for microbiological diagnosis of prosthetic-joint infection at revision arthroplasty: the OSIRIS Collaborative Study Group., J Clin Microbiol, 36, 2932, 10.1128/JCM.36.10.2932-2939.1998 · DOI · Paper page
  4. 1977, Branemark, PI., Hansson, BO., Adell, R., Breine, U., Lindstrom, J., Hallen, O. and Ohman, A. Osseointegrated implants in the treatment of the edentulous jaw: experience from a 10-year period., Scand J Plast Reconstr Surg Suppl, 16, 1
  5. 2001, Branemark, R., Branemark, PI., Rydevik, B. and Myers, RR. Osseointegration in skeletal reconstruction and rehabilitation: a review., J Rehabil Res Dev, 38, 175
  6. 1994, Cordero, J., Munuera, L. and Folgueira, MD. Influence of metal implants on infection: an experimental study in rabbits., J Bone Joint Surg Br, 76, 717
  7. 1981, Kamme, C. and Lindberg, L. Aerobic and anaerobic bacteria in deep infections after total hip arthroplasty: differential diagnosis between infectious and non-infectious loosening., Clin Orthop Relat Res, 154, 201
  8. 2005, Snik, AF., Mylanus, EA., Proops, DW., Wolfaardt, JF., Hodgetts, WE., Somers, T., Niparko, JK., Wazen, JJ., Sterkers, O., Cremers, CW. and Tjellstrom, A. Consensus statements on the BAHA system: where do we stand at present?, Ann Otol Rhinol Laryngol Suppl, 195, 2

Cited by

See all 242

Metadata

Authors
Tillander, J., Hagberg, K., Hagberg, L., & Brånemark, R.
Venue
Clinical Orthopaedics & Related Research
Published
2010-10
Volume
468
Issue
10
Pages
2781-2788
ISSN
0009-921X (ISSN-L)
OpenAlex
W2063423029
Cited by
242
References
1
FWCI
9.94
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Osseointegrated Titanium Implants for Limb Prostheses Attachments: Infectious Complications. https://app.cochat.ai/papers/10.1007/s11999-010-1370-0
The paper
Tillander, J., Hagberg, K., Hagberg, L., & Brånemark, R. (2010). Osseointegrated Titanium Implants for Limb Prostheses Attachments: Infectious Complications. Clinical Orthopaedics & Related Research. https://doi.org/10.1007/s11999-010-1370-0

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.