What is the Minimum Clinically Important Difference in Grip Strength?
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Grip strength reflects functional status of the upper extremity and has been used in many of the clinical studies regarding upper extremity disease or fracture. However, the smallest difference in grip strength that a patient would notice as an improvement resulting from treatment (defined as the minimum clinically important difference [MCID]), to our knowledge has not been determined. QUESTIONS/PURPOSES: We asked (1) how 1-year postsurgery grip strength compares with preinjury values; (2) if grip strength correlated with patient's ratings; (3) what the MCID is in the grip strength; and (4) if these values are equivalent to or greater than what can be explained by measurement errors in patients treated for distal radius fracture. METHODS: Fifty patients treated by volar locking plate fixation for a distal radius fracture constituted the study cohort. Grip strengths were measured 1 year after surgery on the injured and uninjured sides using a dynamometer. Grip strengths before injury were estimated using the grip strengths of the uninjured side with consideration of hand dominance. Patients were asked to rate their subjective level of grip strength weakness at 1 year postoperatively. Receiver operator characteristic curve analysis was used to determine MCIDs. Minimal detectable change in grip strength, which is a statistical estimate of the smallest change between two measurement points expected by measurement error or chance alone, also was determined using the formula 1.65 × √2 × standard error of measurement. RESULTS: One year after surgery, grip strength (23 kg; 95% CI, 20-27) was less compared with calculated preinjury values (28 kg; 95% CI, 25-31; p < 0.001). Patients' rating of grip strength and measured grip strength changes correlated well (p = 0.56). MCIDs were 6.5 kg for grip strength and 19.5% for percentage grip strength. The MCID was not less than the minimum detectable change for grip strength (also 6.5 kg). CONCLUSIONS: The MCID of the grip strength was a decrease of 6.5 kg (19.5%). We believe the MCID of grip strength is useful for evaluating effectiveness of new treatments and for determining appropriate sample size in clinical trials of distal radius fractures. LEVEL OF EVIDENCE: Level III diagnostic study. See the Instructions for Authors for a complete description of levels of evidence.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hudak, P. L., Amadio, P. C., Bombardier, C., Beaton, D., Cole, D., Davis, A., Hawker, G., Katz, J. N., Makela, M., Marx, R. G., et al. (1996) · American Journal of Industrial Medicine · doi:10.1002/(sici)1097-0274(199606)29:6<602::aid-ajim4>3.0.co;2-l · Cited by 5,025
Levine, D. W., Simmons, B. P., Koris, M. J., Daltroy, L. H., Hohl, G. G., Fossel, A. H., & Katz, J. N. (1993) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199311000-00002 · Cited by 1,923 · cited 1×
“Patient-reported instruments for upper extremity outcomes include the Boston Carpal Tunnel Syndrome Questionnaire [13], The DASH questionnaire [7], and the Patient-Rated Wrist Evaluation questionnaire [14].”
MethodGrip Strength and Hand Dominance: Challenging the 10% Rule
Petersen, P., Petrick, M., Connor, H., & Conklin, D. (1989) · The American Journal of Occupational Therapy · doi:10.5014/ajot.43.7.444 · Cited by 490 · cited 2×
“hands [4, 15], therefore we can estimate preinjury grip strength without loss of precision as long as the contralateral side has no previous injury.”
BackgroundHealth Status Measures: Strategies and Analytic Methods for Assessing Change Scores
Stratford, P. W., Binkley, J. M., & Riddle, D. L. (1996) · Physical Therapy · doi:10.1093/ptj/76.10.1109 · Cited by 433 · cited 2×
“0 indicates better differentiation [17].”
BackgroundMeasurement Properties of a Self-Administered Outcome Measure in Lumbar Spinal Stenosis
Stucki, G., Daltroy, L., Liang, M. H., Lipson, S. J., Fossel, A. H., & Katz, J. N. (1996) · Spine · doi:10.1097/00007632-199604010-00004 · Cited by 421 · cited 1×
“Patientreported instruments are being used increasingly in clinical research because such questionnaires are suitable for evaluating treatment outcomes from the patient’s perspective, and the findings are not influenced much by the views of clinicians who were involved in treatment [18].”
BackgroundDevelopment of a Scale for Patient Rating of Wrist Pain and Disability
MacDermid, J. C. (1996) · Journal of Hand Therapy · doi:10.1016/s0894-1130(96)80076-7 · Cited by 405 · cited 1×
“Patient-reported instruments for upper extremity outcomes include the Boston Carpal Tunnel Syndrome Questionnaire [13], The DASH questionnaire [7], and the Patient-Rated Wrist Evaluation questionnaire [14].”
MethodHand strength: Normative values
Cooney, W. P. (1995) · The Journal of Hand Surgery · doi:10.1016/s0363-5023(05)80159-5 · Cited by 370
Grip strength: effects of testing posture and elbow position.
Balogun, J. A., Akomolafe, C. T., & Amusa, L. O. (1991) · PubMed · Cited by 275
Bohannon, R. W., & Schaubert, K. L. (2005) · Journal of Hand Therapy · doi:10.1197/j.jht.2005.07.003 · Cited by 244
Dawson, J., Doll, H., Coffey, J., & Jenkinson, C. (2007) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2007.02.003 · Cited by 236 · cited 1×
“6 was considered a strong correlation [6].”
Symptoms, functional status, and neuromuscular impairment following carpal tunnel release
Katz, J. N., Fossel, K., Simmons, B. P., Swartz, R. A., Fossel, A. H., & Koris, M. J. (1995) · The Journal Of Hand Surgery · doi:10.1016/s0363-5023(05)80265-5 · Cited by 122 · cited 1×
“Patient-reported instruments take into account the patient’s concerns such as symptoms, function, satisfaction with the results of treatment, and quality of life [8].”
BackgroundComparative responsiveness and minimal change for the Oxford Elbow Score following surgery
Dawson, J., Doll, H., Boller, I., Fitzpatrick, R. M., Little, C., Rees, J. L., & Carr, A. J. (2008) · Quality of Life Research · doi:10.1007/s11136-008-9409-3 · Cited by 113 · cited 1×
“In addition, when a new study is initiated, the MCID of the primary outcome variable is used to determine the sample size of a study [5].”
MethodKim, J. K., & Jeon, S. H. (2012) · Journal of Hand Surgery (European Volume) · doi:10.1177/1753193412442137 · Cited by 99 · cited 13×
“If the value of the MCID is less than that of the MDC, the MCID is within the limit of measurement errors or chances.”
BackgroundInfluentialSelf-citationNormative Data on Wrist Function
Klum, M., Wolf, M. B., Hahn, P., Leclère, F. M., Bruckner, T. M., & Unglaub, F. (2012) · The Journal Of Hand Surgery · doi:10.1016/j.jhsa.2012.06.031 · Cited by 78 · cited 1×
“Patients were instructed to maximally squeeze the handle of a dynamometer, sitting on a chair without armrests, both feet flat on the ground, shoulders in the neutral position, and elbows flexed to 90 with neutrally rotated forearm [2, 11].”
MethodKim, J. K., & Park, E. S. (2013) · Clinical Orthopaedics and Related Research · doi:10.1007/s11999-013-2843-8 · Cited by 76 · cited 3×
“The MCIDs for the patient-reported questionnaires have been reported for nontraumatic upper extremity disease [9, 10].”
BackgroundSelf-citation
Cited by
Minimal clinically important difference for grip strength: a systematic review
Bohannon, R. W. (2019) · Journal of Physical Therapy Science · doi:10.1589/jpts.31.75 · Cited by 312
Measurement Properties of the Hand Grip Strength Assessment: A Systematic Review With Meta-analysis
Bobos, P., Nazari, G., Lu, Z., & MacDermid, J. C. (2020) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2019.10.183 · Cited by 223
McLean, R. R., Mangano, K. M., Hannan, M. T., Kiel, D. P., & Sahni, S. (2016) · The Journals of Gerontology Series A: Biological Sciences and Medical Sciences · doi:10.1093/gerona/glv184 · Cited by 175
Handgrip strength: a comparison of values obtained from the NHANES and NIH Toolbox studies
Bohannon, R. W., Wang, Y.-C., Yen, S.-C., & Grogan, K. A. (2019) · American Journal of Occupational Therapy · doi:10.5014/ajot.2019.029538 · Cited by 72
“Measurements of grip strength obtained by dynamometry are easily procured and have been shown to be reliable (Bohannon, 2017), valid (Turner & Ebrahim, 1992), and responsive (Kim et al., 2014).”
MethodEfficacy of Nonoperative Treatments for Lateral Epicondylitis: A Systematic Review and Meta-Analysis
Kim, Y. J., Wood, S. M., Yoon, A. P., Howard, J. C., Yang, L. Y., & Chung, K. C. (2021) · Plastic & Reconstructive Surgery · doi:10.1097/prs.0000000000007440 · Cited by 52
Metadata
- Authors
- Kim, J. K., Park, M. G., & Shin, S. J.
- Venue
- Clinical Orthopaedics & Related Research
- Published
- 2014-08
- Volume
- 472
- Issue
- 8
- Pages
- 2536-2541
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W2068562571
- Cited by
- 182
- References
- 15
- FWCI
- 8.66
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.